Challenges in Clinical Electrocardiography
June 13, 2011

Sustained Ventricular Fibrillation in a Conscious Patient

Author Affiliations
 

JEFFREYTABASMDPAUL D.VAROSYMDGREGORY M.MARCUSMDNORAGOLDSCHLAGERMD

Arch Intern Med. 2011;171(11):973. doi:10.1001/archinternmed.2011.235

A 44-year-old man with a nonischemic dilated cardiomyopathy treated with an implanted left ventricular assist device (LVAD) was admitted to our hospital for diuresis after presenting with acute decompensated heart failure. His admission blood pressure was 95/65 mm Hg. Serial troponin measurements were negative. While hospitalized, the patient developed a wide complex tachycardia on telemetry monitoring resulting in multiple successive discharges from his implantable cardioverter-defibrillator (ICD). On evaluation, the patient was conversant and without complaint of lightheadedness or palpitations. Bilateral radial and femoral pulses were absent. An automated cuff was unable to measure a brachial blood pressure in either arm. An electrocardiogram (ECG) was obtained (Figure 1).