[Skip to Content]
Access to paid content on this site is currently suspended due to excessive activity being detected from your IP address 54.158.169.168. Please contact the publisher to request reinstatement.
[Skip to Content Landing]
Article
October 1974

Ophthalmic Contact B-Scan UltrasonographyA Practical Clinical Tool

Author Affiliations

From the Department of Ophthalmology, Manhattan Eye, Ear and Throat Hospital, New York.

Arch Ophthalmol. 1974;92(4):291-296. doi:10.1001/archopht.1974.01010010301005
Abstract

A new contact B-scan ultrasonography device has been introduced into clinical usage. The results of this portable, simply operated instrument in a variety of ophthalmic conditions are reported. It was found to be a practical clinical tool in providing useful new diagnostic information in both ocular and orbital pathological conditions.

References
1.
Baum G:  Ultrasonography in clinical ophthalmology . Trans Am Acad Ophthalmol Otolaryngol 68:265-276, 1964.
2.
Purnell EW:  Intensity modulated B-scan ultrasonography , in Goldberg RE, Sarin LK (eds): Ultrasonics in Ophthalmology , Philadelphia, WB Saunders, 1967, pp 102-123.
3.
Coleman DJ, Konig WF, Katz L:  A hand-operated ultrasound scan system for ophthalmic evaluation . Am J Ophthalmol 68:256-263, 1969.
4.
Holasek E, Sokollu A:  Direct Contact, hand-held B-scanner . Proceedings of the Institute of Electronic and Electrical Engineering Ultrasonics Symposium , Boston, Institute of Electrical and Electronics Engineers, Inc., October 1972, pp 38-43.
5.
Ossoinig K:  Clinical echo-ophthalmography , in Blodi FC (ed): Current Concepts of Ophthalmology . St Louis, CV Mosby Co, 1972, vol 3, pp 101-130.
6.
Bronson NR:  Development of a simple B-scan ultrasonoscope . Trans Am Ophthalmol Soc 70:365-408, 1972.
7.
Bronson NR, Turner FT:  A simple B-scan ultrasonoscope . Arch Ophthalmol 90:237-238, 1973.Article
8.
Coleman DJ:  Ultrasound in vitreous surgery . Trans Am Acad Ophthalmol Otolaryngol 76:467-479, 1972.
9.
Coleman DJ, Jack RL, Cardona H:  Ultrasonic evaluation of eyes with keratoprostheses . Am J Ophthalmol 74:543-554, 1972.
10.
Coleman DJ, Carrol FD:  Evaluation of optic neuropathy with B-scan ultrasonography . Am J Ophthalmol 74:915-920, 1972.
11.
Coleman DJ:  Reliability of ocular and orbital diagnosis with B-scan ultrasound: I. Ocular diagnosis . Am J Ophthalmol 73:501-516, 1972.
12.
Coleman DJ:  Reliability of ocular and orbital diagnosis with B-scan ultrasound: II. Orbital diagnosis . Am J Ophthalmol 74:704-718, 1972.
13.
Coleman DJ, Jack RL, Franzen LA:  High resolution B-scan ultrasonography of the orbit: I. The normal orbit . Arch Ophthalmol 88:358-367, 1972.Article
14.
Coleman DJ, Jack RL, Franzen LA, et al:  High resolution B-scan ultrasonography of the orbit: V. Eye changes of Graves' Disease . Arch Ophthalmol 88:465-471, 1972.Article
15.
Coleman DJ, Jack RL, Jones IS, et al:  High resolution B-scan ultrasonography of the orbit: VI. Pseudotumors of the orbit . Arch Ophthalmol 88:472-480, 1972.Article
16.
Jack RL, Coleman DJ:  Detection of retinal detachment secondary to choroidal melanoma with B-scan ultrasonography . Am J Ophthalmol 74:1057-1065, 1972.
17.
Metz GA, Bronson NR:  Ultrasonic appearance of senile lens changes , in Gitter KA, Keeney AH, Sarin LK, et al (eds): Ophthalmic Ultrasound . St Louis, CV Mosby, 1969, pp 218-223.
×