[Skip to Content]
[Skip to Content Landing]
Article
June 1975

Expandable Silicone Implants for Scleral BucklingIV. Experiments With An Explant for Macular Breaks

Author Affiliations

From the Retina Foundation, Boston. Dr. Huamonte is now at the University of Illinois Eye and Ear Infirmary, Chicago.

Arch Ophthalmol. 1975;93(6):429-431. doi:10.1001/archopht.1975.01010020443010
Abstract

A new expandable silicone rubber explant used to indent the sclera at the macula was tested experimentally in rabbits. The device consists of a Dacron-reinforced silicone rubber strip that has an expandable portion (or balloon) at its midpoint connected to a silicone filling tube. The explant was expanded with 0.03 to 0.06 ml of an antibiotic solution. Smooth, round buckles that exerted even indentation were produced. A decrease in height of 20% to 50% was observed ophthalmoscopically during six months of follow-up. The degree of buckling can be easily controlled during operation and may be modified postoperatively.

References
1.
Knapp H:  Ueber isolirte Zerreissungen der Aderhaut in Folge von Traumen auf dem Augapfel . Arch Augen Ohrenheilkd 1:6, 1869.
2.
Margherio RR, Schepens CL:  Macular breaks: 1. Diagnosis, etiology, and observations . Am J Ophthalmol 74:219-232, 1972.
3.
Schepens CL, Okamura ID, Brockhurst RJ:  The scleral buckling procedures: I. Surgical techniques and management . Arch Ophthalmol 58:797-811, 1957.Article
4.
Klöti R:  Eine Operationsmethode für maculalochbedingte Netzhautablösungen . Ophthalmologica 148:42-56, 1964.Article
5.
Rosengren B:  The silver plomb method in macular holes . Trans Ophthalmol Soc UK 86:49-53, 1966.
6.
Havener WH, Gloeckner S: Atlas of Diagnostic Techniques and Treatment of Retinal Detachment . St. Louis, CV Mosby, 1967.
7.
Pannarale MR:  Techniques de traitement du décollement avec déchirures tres postérieures . Bibl Ophthalmol 70:239-245, 1966.
8.
Paufique L, Bonnet M:  Traitment du décollement de la rétine avec déchirure vraie de la macula par la technique de la "poche scléral." Ann Ocul (Paris) 201:290-302, 1968.
9.
Long RS, Mittl R, Chuanico R:  Experimental scleral buckling of the posterior pole using tissue adhesive . Am J Ophthalmol 69:419-422, 1970.
10.
Margherio RR, Schepens CL:  Macular breaks: 2. Management . Am J Ophthalmol 74:233-240, 1972.
11.
Banuelos A, Refojo MF, Schepens CL:  Expandable silicone implants for scleral buckling: I. Introduction of a new concept . Arch Ophthalmol 89:500-502, 1973.Article
12.
Refojo MF, Banuelos A:  Expandable silicone implants for scleral buckling: II. Experiments in vitro . Arch Ophthalmol 90:127-130, 1973.Article
13.
Huamonte F, Refojo MF, Banuelos A:  Expandable silicone implants for scleral buckling: III. Experiments in vivo . Arch Ophthalmol , 93:354-356, 1975.Article
×