October 1986

Computed Tomographic Three-Dimensional Localization and Compositional Evaluation of Intraocular and Orbital Foreign Bodies

Author Affiliations

From the Neuroradiology Division, the Russell H. Morgan Department of Radiology and Radiological Sciences (Drs Zinreich and Rosenbaum, and Ms Quinn and Mr Hadfield) and the Orbital Unit, The Wilmer Eye Institute (Drs Miller and Aguayo), The Johns Hopkins Medical Institutions, Baltimore.

Arch Ophthalmol. 1986;104(10):1477-1482. doi:10.1001/archopht.1986.01050220071029
Abstract

• A software program designed for the Siemens Somatom DR3 computed tomographic (CT) scanner provides improved diagnosis, localization, and etiologic description of intraocular and orbital foreign bodies. The program allows information to be analyzed in two different display formats. One format is that of multiplanar reconstruction of the eye and orbit, including an "oblique CT cube" image. This format produces an accurate "three-dimensional" display of both in vitro and in vivo intraocular and orbital foreign bodies. The second display format is that of a histogram. Using this analytic mode, nonmetallic intraocular and intraorbital foreign bodies can be differentiated from each other and from metallic foreign bodies, although individual metallic foreign bodies cannot be identified with respect to specific composition. The information provided by these two display formats substantially aids the clinician in the diagnosis and management of foreign bodies located within the orbit, particularly those located within the eye.

References
1.
Kadir S, Aronow S, Davis KR:  The use of computerized tomography in the detection of intra-orbital foreign bodies . Comput Tomogr 1977;1:151-156.Article
2.
Grove AS Jr:  Orbital trauma evaluation by computed tomography . Comput Tomogr 1979; 3:267-278.Article
3.
Lobes LA Jr, Grand MG, Reece J, et al:  Computerized axial tomography in the detection of intraocular foreign bodies . Ophthalmology 1981;88:26-30.Article
4.
Coleman DJ, Trokel SL:  A protocol for Bscan and radiographic foreign body localization . Am J Ophthalmol 1971;71:84-89.
5.
Zinreich SJ, Rosenbaum AE, Schwebel JC, et al: Multiplanar reconstruction selective planar reconstruction makes CT more comprehensible and diagnostic. Presented at the Radiological Society of North America Annual Meeting, Washington, DC, 1984.
6.
Tate E, Cupples H:  Detection of orbital foreign bodies with computed tomography: Current limits . Am J Radiol 1981;137:493-495.
7.
Kollarits CR, DiChiro G, Christiansen J, et al:  Detection of orbital and intraocular foreign bodies by computerized tomography . Ophthalmic Surg 1977;8:45-52.
×