April 1987

Lens Clarity After Argon and Neodymium-YAG Laser Iridotomy in the Rabbit

Author Affiliations

From the Department of Ophthalmology, University of Illinois College of Medicine at Chicago.

Arch Ophthalmol. 1987;105(4):540-541. doi:10.1001/archopht.1987.01060040110045
Abstract

• Focal lenticular damage has occurred after argon and neodymium (Nd)YAG laser iridotomies. Since the latter disrupts nonpigmented membranes, it is of particular concern. To determine the effects of argon and Nd-YAG laser iridotomies on the lens, we treated adult pigmented rabbits and quantitatively evaluated their lenses. The right eyes of ten adult pigmented rabbits underwent argon laser (five eyes) or Nd-YAG laser (five eyes) iridotomies. The left eyes served as controls and were not treated. The Scheimpflug camera (Zeiss) and fluorophotometry were used to quantitate lens clarity six weeks postoperatively. There was no statistically significant difference in lens clarity between treatment groups when the experimental and control eyes were compared after six weeks. Thus, no diffuse lens opacification appeared evident after argon laser or Nd-YAG laser iridotomy.

References
1.
Schrems W, van Drop HP, Wendel M, et al:  The effect of YAG laser iridotomy on the blood aqueous barrier in the rabbit . Graefes Arch Clin Exp Ophthalmol 1984;221:179-181.Article
2.
Latina MA, Puliafito CA, Steinert RR, et al:  Experimental iridotomy with the Q-switched neodymium-YAG laser . Arch Ophthalmol 1984;102:1211-1213.Article
3.
Dragon DM, Robin AL, Pollack IP, et al:  Neodymium:YAG laser iridotomy in the cynomolgus monkey . Invest Ophthalmol Vis Sci 1985;26:789-796.
4.
Richardson TM, Brown SV, Thomas JV, et al:  Shock-wave effect on anterior segment structure following experimental neodymium:YAG laser iridotomy . Ophthalmology 1985;92:1387-1395.Article
5.
Welch DB, Apple DJ, Mendelsohn AD, et al:  Lens injury following iridotomy with a Q-switched neodymium-YAG laser . Arch Ophthalmol 1986;104:123-125.Article
6.
Robin A, Pollack I:  A comparison of neodymium:YAG and argon laser iridotomies . Ophthalmology 1984;91:1011-1016.Article
7.
Schwartz L, Mosser M, Spaeth G, et al:  Neodymium:YAG laser iridectomies in glaucoma associated with closed or occludable angles . Am J Ophthalmol 1986;102:41-44.
8.
Gaasterland DE, Rodrigues NN, Thomas G:  Threshold for lens damage during Q-switched Nd:YAG laser iridectomy . Ophthalmology 1985;92:1616-1623.Article
9.
Seedor JA, Greenidge KC, Dunn N:  Neodymium:YAG laser iridectomy and acute cataract formation in the rabbit . Ophthalmic Surg 1986;17:478-482.
10.
Shapiro A, Tso M, Goldberg M:  Argon laser-induced cataract: A clinicopathologic study . Arch Ophthalmol 1984;102:579-583.Article
11.
Hockwin O, Dragomirescu V, Koch H-R:  Photographic documentation of the lens transparency during aging with a Scheimpflug camera system . Ophthalmic Res 1979;11:405-410.Article
12.
Lerman S, Hockwin O, Dragomirescu V:  In vivo fluorescence photography . Ophthalmic Res 1981;13:224-228.Article
13.
Hockwin O, Lerman S, Ohrloff C:  Investigations on lens transparency and its disturbances by microdensitometric analyses of Scheimpflug photograph . Curr Eye Res 1984;3:15-22.Article
14.
Zeimer RC, Noth JM:  A new method of measuring in vivo the lens transmittance, and study of lens scatter, fluorescence and transmittance . Ophthalmic Res 1984;16:246-255.Article
15.
Bleeker JC, van Best JA, Vrij L, et al:  Autofluorescence of the lens in diabetic and healthy subjects by fluorophotometry . Invest Ophthalmol Vis Sci 1986;27:791-794.
16.
Zeimer RC, Cunha-Vaz JG, Johnson ME:  Studies on the technique of vitreous fluorophotometry . Invest Ophthalmol Vis Sci 1981;22:668-674.
×