Figure 1.
CONSORT Diagram
CONSORT Diagram

OAm indicates oral mandibular advancement device.

Figure 2.
Incidence of the Most Frequently Reported Adverse Effects During OAm Therapy
Incidence of the Most Frequently Reported Adverse Effects During OAm Therapy

Adverse effects were subjectively scored. Unpleasant sensations in the teeth, pain in the teeth, hypersalivation, and pain in the temporomandibular joint (TMJ) were the most reported adverse effects. OAm indicates oral mandibular advancement device.

Figure 3.
Correlation Between Objective Mean Wearing Time and Snoring Parameters
Correlation Between Objective Mean Wearing Time and Snoring Parameters

The correlation between the objective mean wearing time at the 3-month follow-up visit and scores on the visual analog scale for snoring with the oral mandibular advancement device (OAm) as well as the decrease in scores on the visual analog scale for snoring with the OAm compared with baseline. A, Visual analog scale scores for snoring with the OAm (P = .006; ρ = –0.40). B, Decrease in scores on the visual analog scale for snoring with the OAm compared with baseline (P = .005; ρ = 0.39). A positive value is regarded as a decrease in visual analog scale score.

Table 1.  
Objective Compliance Data 1 and 3 Months After the Start of OAm Therapy
Objective Compliance Data 1 and 3 Months After the Start of OAm Therapy
Table 2.  
Polysomnographic Parameters at Baseline and After 3 Months of OAm Therapy
Polysomnographic Parameters at Baseline and After 3 Months of OAm Therapy
Table 3.  
Correlation Between Study Variables and Objective Mean Wearing Time
Correlation Between Study Variables and Objective Mean Wearing Time
1.
Malhotra  A, White  DP.  Obstructive sleep apnoea. Lancet. 2002;360(9328):237-245.
PubMedArticle
2.
Anstead  M, Phillips  B.  The spectrum of sleep-disordered breathing. Respir Care Clin N Am. 1999;5(3):363-377, viii.
PubMed
3.
Peppard  PE, Young  T, Barnet  JH, Palta  M, Hagen  EW, Hla  KM.  Increased prevalence of sleep-disordered breathing in adults. Am J Epidemiol. 2013;177(9):1006-1014.
PubMedArticle
4.
 Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research: the report of an American Academy of Sleep Medicine Task Force. Sleep. 1999;22(5):667-689.
PubMed
5.
Collop  NA.  Obstructive sleep apnea syndromes. Semin Respir Crit Care Med. 2005;26(1):13-24.
PubMedArticle
6.
Guilleminault  C, Tilkian  A, Dement  WC.  The sleep apnea syndromes. Annu Rev Med. 1976;27:465-484.
PubMedArticle
7.
Tkacova  R, Dorkova  Z. Clinical Presentations of OSA in Adults: European Respiratory Society Monograph. Norwich, UK: European Respiratory Society; 2010:86-103.
8.
Vanderveken  OM, Boudewyns  A, Ni  Q,  et al.  Cardiovascular implications in the treatment of obstructive sleep apnea. J Cardiovasc Transl Res. 2011;4(1):53-60.
PubMedArticle
9.
Marin  JM, Carrizo  SJ, Vicente  E, Agusti  AG.  Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. 2005;365(9464):1046-1053.
PubMedArticle
10.
Bradley  TD, Floras  JS.  Obstructive sleep apnoea and its cardiovascular consequences. Lancet. 2009;373(9657):82-93.
PubMedArticle
11.
Yaggi  HK, Concato  J, Kernan  WN, Lichtman  JH, Brass  LM, Mohsenin  V.  Obstructive sleep apnea as a risk factor for stroke and death. N Engl J Med. 2005;353(19):2034-2041.
PubMedArticle
12.
Somers  VK, White  DP, Amin  R,  et al.  Sleep apnea and cardiovascular disease: an American Heart Association/American College of Cardiology Foundation scientific statement from the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on Clinical Cardiology, Stroke Council, and Council on Cardiovascular Nursing. J Am Coll Cardiol. 2008;52(8):686-717.
PubMedArticle
13.
Epstein  LJ, Kristo  D, Strollo  PJ  Jr,  et al; Adult Obstructive Sleep Apnea Task Force of the American Academy of Sleep Medicine.  Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med. 2009;5(3):263-276.
PubMed
14.
Sullivan  CE, Issa  FG, Berthon-Jones  M, Eves  L.  Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet. 1981;1(8225):862-865.
PubMedArticle
15.
Kushida  CA, Littner  MR, Hirshkowitz  M,  et al; American Academy of Sleep Medicine.  Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. Sleep. 2006;29(3):375-380.
PubMed
16.
Phillips  CL, Grunstein  RR, Darendeliler  MA,  et al.  Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea: a randomized controlled trial. Am J Respir Crit Care Med. 2013;187(8):879-887.
PubMedArticle
17.
Vanderveken  OM.  Perspectives on the reduction in cardiovascular mortality with oral appliance therapy for patients with severe obstructive sleep apnoea intolerant to continuous positive airway pressure. Respirology. 2013;18(8):1161-1162.
PubMedArticle
18.
Marklund  M, Verbraecken  J, Randerath  W.  Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy. Eur Respir J. 2012;39(5):1241-1247.
PubMedArticle
19.
Tsuiki  S, Lowe  AA, Almeida  FR, Kawahata  N, Fleetham  JA.  Effects of mandibular advancement on airway curvature and obstructive sleep apnoea severity. Eur Respir J. 2004;23(2):263-268.
PubMedArticle
20.
Ng  A, Gotsopoulos  H, Darendeliler  AM, Cistulli  PA.  Oral appliance therapy for obstructive sleep apnea. Treat Respir Med. 2005;4(6):409-422.
PubMedArticle
21.
Clark  GT, Arand  D, Chung  E, Tong  D.  Effect of anterior mandibular positioning on obstructive sleep apnea. Am Rev Respir Dis. 1993;147(3):624-629.
PubMedArticle
22.
Ravesloot  MJ, de Vries  N.  Reliable calculation of the efficacy of non-surgical and surgical treatment of obstructive sleep apnea revisited. Sleep. 2011;34(1):105-110.
PubMed
23.
Kribbs  NB, Pack  AI, Kline  LR,  et al.  Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis. 1993;147(4):887-895.
PubMedArticle
24.
Pépin  JL, Krieger  J, Rodenstein  D,  et al.  Effective compliance during the first 3 months of continuous positive airway pressure: a European prospective study of 121 patients. Am J Respir Crit Care Med. 1999;160(4):1124-1129.
PubMedArticle
25.
Krieger  J, Kurtz  D.  Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome. Eur Respir J. 1988;1(5):436-438.
PubMed
26.
Grote  L, Hedner  J, Grunstein  R, Kraiczi  H.  Therapy with nCPAP: incomplete elimination of sleep related breathing disorder. Eur Respir J. 2000;16(5):921-927.
PubMedArticle
27.
Vanderveken  OM, Dieltjens  M, Wouters  K, De Backer  WA, Van de Heyning  PH, Braem  MJ.  Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing. Thorax. 2013;68(1):91-96.
PubMedArticle
28.
Dieltjens  M, Braem  MJ, Vroegop  AV,  et al.  Long-term objective compliance measurement during oral appliance therapy in patients with sleep-disordered breathing: 1 year follow-up [abstract 0408]. Sleep. 2012;35(suppl):A141-A142.
29.
de Almeida  FR, Lowe  AA, Tsuiki  S,  et al.  Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome. J Clin Sleep Med. 2005;1(2):143-152.
PubMed
30.
Marklund  M, Franklin  KA.  Long-term effects of mandibular repositioning appliances on symptoms of sleep apnoea. J Sleep Res. 2007;16(4):414-420.
PubMedArticle
31.
Marklund  M, Stenlund  H, Franklin  KA.  Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest. 2004;125(4):1270-1278.
PubMedArticle
32.
Dieltjens  M, Vanderveken  OM, Hamans  E,  et al.  Treatment of obstructive sleep apnea using a custom-made titratable duobloc oral appliance: a prospective clinical study. Sleep Breath. 2013;17(2):565-572.
PubMedArticle
33.
Schott  TC, Göz  G.  Applicative characteristics of new microelectronic sensors Smart Retainer and TheraMon for measuring wear time. J Orofac Orthop. 2010;71(5):339-347.
PubMedArticle
34.
Johns  MW.  A new method for measuring daytime sleepiness: the Epworth Sleepiness Scale. Sleep. 1991;14(6):540-545.
PubMed
35.
Vanderveken  OM, Devolder  A, Marklund  M,  et al.  Comparison of a custom-made and a thermoplastic oral appliance for the treatment of mild sleep apnea. Am J Respir Crit Care Med. 2008;178(2):197-202.
PubMedArticle
36.
McGown  AD, Makker  HK, Battagel  JM, L’Estrange  PR, Grant  HR, Spiro  SG.  Long-term use of mandibular advancement splints for snoring and obstructive sleep apnoea: a questionnaire survey. Eur Respir J. 2001;17(3):462-466.
PubMedArticle
37.
Woodson  BT, Han  JK.  Relationship of snoring and sleepiness as presenting symptoms in a sleep clinic population. Ann Otol Rhinol Laryngol. 2005;114(10):762-767.
PubMedArticle
38.
Sutherland  K, Vanderveken  OM, Tsuda  H,  et al.  Oral appliance treatment for obstructive sleep apnea: an update. J Clin Sleep Med. 2014;10(2):215-227.
PubMed
39.
Ten Berge  DM, Braem  MJ, Altenburg  A,  et al.  Evaluation of the impact of a clinical pathway on the organization of a multidisciplinary dental sleep clinic. Sleep Breath. 2014;18(2):325-334.
PubMedArticle
40.
Ferguson  KA, Cartwright  R, Rogers  R, Schmidt-Nowara  W.  Oral appliances for snoring and obstructive sleep apnea: a review. Sleep. 2006;29(2):244-262.
PubMed
41.
Basoglu  OK, Midilli  M, Midilli  R, Bilgen  C.  Adherence to continuous positive airway pressure therapy in obstructive sleep apnea syndrome: effect of visual education. Sleep Breath. 2012;16(4):1193-1200.
PubMedArticle
42.
Bouloukaki  I, Giannadaki  K, Mermigkis  C,  et al.  Intensive versus standard follow-up to improve continuous positive airway pressure compliance. Eur Respir J. 2014;44(5):1262-1274.
PubMedArticle
Views 577
Citations 0
Original Investigation
October 2015

Determinants of Objective Compliance During Oral Appliance Therapy in Patients With Sleep-Disordered BreathingA Prospective Clinical Trial

Author Affiliations
  • 1Department of Special Care Dentistry, Antwerp University Hospital, Edegem, Antwerp, Belgium
  • 2Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
  • 3Department of Otolaryngology and Head and Neck Surgery, Antwerp University Hospital, Edegem, Antwerp, Belgium
  • 4Department of Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Edegem, Antwerp, Belgium
  • 5Department of Pneumology, Antwerp University Hospital, Edegem, Antwerp, Belgium
  • 6Department of Scientific Coordination and Biostatistics, Antwerp University Hospital, Edegem, Antwerp, Belgium
JAMA Otolaryngol Head Neck Surg. 2015;141(10):894-900. doi:10.1001/jamaoto.2015.1756
Abstract

Importance  The main reported reasons for discontinuation of oral appliance therapy for sleep-disordered breathing (SDB) are the presence of self-perceived adverse effects and self-appreciated lack of efficacy. However, these conclusions rely only on subjective compliance data.

Objective  To determine which parameters are correlated with objectively measured data on compliance with oral appliance therapy.

Design, Setting, and Participants  For 51 outpatients with SDB, a prospective clinical trial using oral appliance therapy was conducted at Antwerp University Hospital from February 7, 2011, to October 8, 2013 (38 [75%] males; mean [SD] age, 49.3 [9.0] years; mean [SD] apnea-hypopnea index, 14.9 [9.3] events per hour of sleep; mean [SD] body mass index [calculated as weight in kilograms divided by height in meters squared], 26.3 [2.8]). Analysis was performed November 5, 2014.

Intervention  Oral appliance therapy with a custom-made, titratrable mandibular advancement device (OAm).

Main Outcomes and Measures  Possible correlations were assessed between objective compliance and patients’ anthropometric characteristics, polysomnographic parameters, and answers to 3 subjective questionnaires (the visual analog scale for snoring, the Epworth Sleepiness Scale, and an adverse effects questionnaire).

Results  Median oral appliance use was 6.4 hours per night (range, 4.7-7.2 hours per night) at the 3-month follow-up. None of the anthropometric and polysomnographic parameters were correlated with compliance. No correlation was found between objective compliance and reports of excessive daytime sleepiness. However, a significant inverse correlation was found between objective compliance and posttreatment visual analog scale values for snoring (P = .006; ρ = –0.40). In addition, objective compliance was correlated significantly with a more pronounced decrease in socially disturbing snoring (P = .005; ρ = 0.39). The presence of dry mouth was the only adverse effect that was negatively correlated with objective compliance at the 3-month follow-up (P < .05; ρ = –0.31).

Conclusions and Relevance  Neither the anthropometric and polysomnographic parameters nor reports of excessive daytime sleepiness correlated with compliance during oral appliance therapy. The 2 parameters that were correlated with higher objective compliance during oral appliance therapy were a more pronounced decrease in snoring and the presence of dry mouth during treatment.

Trial Registration  clinicaltrials.gov Identifiers: NCT01284881 and NCT01532050

Introduction

Sleep-disordered breathing (SDB) comprises a pathophysiologic spectrum of sleep-related breathing abnormalities, ranging from snoring to the more severe obstructive sleep apnea-hypopnea syndrome.1,2 Obstructive sleep apnea (OSA) among adults is a prevalent public health issue, affecting approximately 26.6% to 33.9% of adult men and 8.7% to 27.8% of adult women.3 It is characterized by repetitive episodes of partial or complete upper airway obstruction during sleep.46 Obstructive sleep apnea is often associated with excessive daytime sleepiness, impaired cognitive performance, reduced quality of life7 and is a strong and independent risk factor for cerebrovascular and cardiovascular diseases.812 The severity of sleep apnea is expressed by the apnea-hypopnea index (AHI), which is defined as the number of apneas and hypopneas per hour of sleep.4,13 A diagnosis of sleep apnea is confirmed when the AHI is 5 events or more per hour of sleep. Mild sleep apnea is defined as an AHI of 5 to less than 15 events per hour, moderate sleep apnea as an AHI of 15 to less than 30 events per hour, and severe sleep apnea as an AHI of 30 events or more per hour.4,13

Therapy with continuous positive airway pressure (CPAP) provides a pneumatic splint of the upper airway by applying constant positive pressure throughout the respiratory cycle.14 Therapy with CPAP has proved to be efficacious in reducing apnea severity and is currently the recommended therapy for patients with moderate to severe OSA.15 Oral appliance (OA) therapy is increasingly prescribed as a noninvasive treatment option for patients with mild to moderate OSA who prefer OA therapy to CPAP therapy, who do not respond to CPAP therapy, who are not appropriate candidates for CPAP therapy, or who fail treatment attempts with CPAP therapy.13,15 As a consequence, OA therapy is increasingly prescribed in patients with severe OSA who do not comply with or who refuse CPAP therapy.16,17

The most common type of OA therapy for the treatment of OSA is an oral mandibular advancement device (OAm) worn intraorally during sleep.18 The OAm’s mechanism of action in patients who respond to treatment causes enlargement of the cross-sectional upper airway dimensions by anterior displacement of the mandible and the attached tongue, resulting in improved upper airway patency.1821

Neither CPAP nor OAm therapy eliminates the underlying causes of upper airway collapse, so both are lifelong treatments that prevent upper airway obstruction. Given the fact that even the most efficacious medical device is only effective when used appropriately, follow-up to assess compliance during CPAP and OAm therapy is of primary importance.22

As part of the clinical routine, CPAP therapy incorporates an objective measurement of use.2325 This objective compliance measurement reveals that the clinical effectiveness of CPAP therapy is often limited by low patient acceptance, poor tolerance, and suboptimal compliance.23,26 Some studies evaluated the correlations between objective compliance data and anthropometric and polysomnographic variables such as age, body mass index (BMI), sex, mean nocturnal saturation, and severity of SDB.23,24 When comparing compliant and noncompliant patients, both groups showed similar anthropometric and polysomnographic data before the start of treatment. In addition, an identical percentage of patients reported improvement in snoring and daytime sleepiness in the compliant and noncompliant subgroups, and there was no difference in reported adverse effects.24 However, satisfaction with CPAP therapy and a better daytime energy level with CPAP therapy correlated with objective frequency of CPAP use.23

Previous studies of OAm therapy compliance were limited to self-reported use and lacked an objective compliance measurement. Only recently has an objective compliance monitor become available to the market.27 This monitor indirectly allows for the calculation of the therapeutic effectiveness of OAm therapy, which seems to be characterized by suboptimal efficacy combined with rather high compliance.27,28 Although studies showed high compliance during OAm therapy, the main reported reasons for discontinuation of OAm therapy include the presence of self-perceived adverse effects such as excessive salivation, xerostomia, tooth and gingival discomfort, temporomandibular joint discomfort,29,30 and self-appreciated lack of efficacy. These reasons for discontinuation emphasize the patient’s perception of the treatment.29,31 However, these conclusions rely only on subjective compliance data. The aim of our study was, therefore, to determine the relevant treatment parameters that correlate with objectively measured compliance with OAm therapy.

Methods
Patient Population and Design

In Belgium, CPAP therapy is the standard treatment for patients with moderate to severe OSA (AHI of >20 events per hour), and patients undergoing this therapy are fully reimbursed. Therefore, our policy is to propose a trial of CPAP therapy to any patient with an AHI of at least 20 events per hour. In our multidisciplinary setting, patients with mild SDB (AHI of <20 events per hour) and patients with intolerance to CPAP therapy are referred to the multidisciplinary dental sleep clinic involved in the decision making for the implementation of OAm therapy in patients with OSA.

All patients who presented to our outpatient clinic from February 7, 2011, to October 8, 2013, with SDB based on results of a recent overnight polysomnography and who were candidates for OAm therapy were invited to participate in a prospective clinical study. The full study protocol can be found in the trial protocol in the Supplement. Seventy adult patients with SDB (male, 56 [80%]; mean [SD] age, 47.8 [9.4] years; mean [SD] AHI, 17.0 [11.5] events per hour; mean [SD] BMI [calculated as weight in kilograms divided by height in meters squared], 26.7 [2.9]) were included after written informed consent was obtained. Ethical approval for this study was obtained from the Antwerp University Hospital and University of Antwerp Institutional Review Board. All patients started treatment with a custom-made oral appliance (RespiDent Butterfly, Dormoco).32 The OAm therapy included strict multidisciplinary follow-up, with visits at 1 and 3 months after the start of therapy. After 3 months of OAm therapy, all patients were invited to undergo polysomnography overnight with the OAm in situ. Analysis was performed November 5, 2014.

Objective Compliance

Objective compliance during OAm therapy was obtained at the 1- and 3-month follow-up visits using a temperature-sensitive microsensor (TheraMon, Handels- und Entwicklungsgesellschaft, Handelsagentur Gschladt) embedded in the upper right side of the OAm.27,33 Temperature was recorded by the microsensor at a sampling rate of 1 measurement every 15 minutes, allowing data acquisition for 100 consecutive days. Objective compliance measurement was based on the assumption that the OAm was worn when a temperature greater than 35°C was recorded.27 Participants were informed that a microsensor was embedded in the OAm to serve fundamental research of intraoral mucosal temperature shifts during the night and as such were blinded to the aim of the study, resulting in covert monitoring of compliance.

For each patient, the average OAm use in hours per night and in percentage of days per week was calculated and was referred to as the objective mean wearing time. Similar to definitions used in the literature for CPAP therapy, patients with an average individual use of at least 4 hours per night were considered compliant,23 while patients who used the OAm at least 4 hours per night on at least 70% of all nights were considered regular users.23

Treatment Outcome

Responders were defined as patients with an AHI reduction of at least 50% compared with baseline. Treatment success was defined as an AHI of fewer than 5 events per hour on the follow-up polysomnography while using the OAm.

Subjective Questionnaires

At both the 1- and 3-month follow-up visits, patients were asked to complete a questionnaire regarding the subjective symptoms of excessive daytime sleepiness and snoring. Patients also completed a separate questionnaire indicating how frequently (never, rarely, occasionally, often, or always) they experienced some of the most commonly reported adverse effects (excessive salivation, xerostomia, tooth discomfort or pain, and temporomandibular joint discomfort or pain).

Epworth Sleepiness Scale

Daytime sleepiness was assessed using the Epworth Sleepiness Scale (ESS), a self-administered questionnaire.34 The ESS measures the probability of falling asleep in 8 different sedentary situations. The total ESS score can range from 0 to 24, with a score of 11 or more being indicative of excessive daytime sleepiness.34

Visual Analog Scale for Snoring

The subjective report of snoring by the bed partner was assessed using a 10-point visual analog scale (VAS) ranging from 0 to 10. A score of 0 indicates no snoring, and a score of 10 indicates snoring that causes the bed partner to leave the room or go to sleep separately.35 A decrease of at least 3 points on the VAS during treatment with OAm compared with baseline recordings represents a decrease of 1 level of snoring severity and is considered to be satisfactory. To be considered an important reduction, snoring had to be reduced to a level that was no longer evaluated as bothersome, meaning a score of 3 points or fewer on the VAS.

Statistical Analysis

Results are presented as mean (SD) if normally distributed and as median (Q1-Q3) if not. Possible correlations between objective compliance and patients’ anthropometric characteristics (sex, age, height, weight, and BMI), polysomnographic parameters (AHI, total sleep time, oxygen desaturation index, minimal and mean oxygen saturation, and OAm efficacy), and answers to the subjective questionnaires (VAS for snoring, ESS for excessive daytime sleepiness, and the adverse effects questionnaire) were evaluated using Spearman rank correlation. A linear regression model was used to study the effect of a combination of the parameters above on compliance. A stepwise model building procedure was applied, and normality of the residuals was checked.

Results
Patient Population

Seventy adult patients with SDB were included in this study. Two patients did not return for the 1-month follow-up visit; thus, compliance data could not be obtained for those patients. At the 3-month follow-up, the microsensor data exceeded the 100-day storage period for 6 patients. In addition, 11 patients did not return and were thus considered lost to follow-up (Figure 1).

For the complete 3-month follow-up period, objective compliance data were thus available for 51 patients (male, 38 [75%]; mean [SD] age, 49.3 [9.0] years; mean [SD] AHI, 14.9 [9.3] events per hour of sleep; and mean [SD] BMI, 26.3 [2.8]).

Objective Compliance

For 51 patients, objective compliance was determined 1 and 3 months after the start of OAm therapy. At the 1-month follow-up, median compliance was 6.2 hours per night (range, 5.1-7.4 hours per night), with a median use of 93.1% (range, 77.5%-100%) of the nights. Forty-two patients (82%) were considered compliant, and 37 (73%) were classified as regular users (Table 1).

Three months after the start of OAm therapy, the OAm was used for 6.4 hours per night (range, 4.7-7.2 hours per night) on a median of 92.2% (range, 73.6%-98.4%) of the nights. At the 3-month follow-up, 42 patients (82%) could be considered compliant, and 36 (71%) were classified as regular users (Table 1).

Treatment Outcome

Baseline polysomnography and polysomnography with the OAm in situ were performed for all 51 patients (Table 2). The mean (SD) AHI decreased significantly from 14.9 (9.3) hours per night at baseline to 8.3 (7.8) hours per night (P < .001) with the OAm in situ after 3 months of treatment. Twenty-six patients (51%) were defined as responders, with an AHI reduction of 50% or more, and 21 patients (41%) met the criteria for treatment success (AHI of <5 events per hour of sleep during polysomnography with OAm).

Subjective Questionnaires

The total mean (SD) ESS score for all patients decreased significantly with OAm therapy from 10.1 (4.9) at baseline to 6.8 (4.4) with OAm (P < .001). Twenty-two patients (43%) reported excessive daytime sleepiness with an ESS score (out of 24) of 11 or greater at baseline. Of these patients, excessive daytime sleepiness was completely eliminated with OAm therapy (ie, ESS score of <11) in 12 patients (55%). All but 1 of these 12 patients were considered compliant and regular users at the 3-month follow-up.

A satisfactory decrease in snoring was seen with OAm therapy: 19 patients (37%) had a decrease of 3 or more points on the VAS. All these patients were compliant users and 16 (84%) were regular users.

Adverse effects were subjectively scored. Unpleasant sensations in the teeth (14 of 20 patients [70%]), pain in the teeth (27 of 45 [60%]), hypersalivation (24 of 45 [53%]), and pain in the temporomandibular joint (24 of 45 [53%]) were the most reported adverse effects (Figure 2).

Correlations

At the 1- and 3-month-follow-up visits, none of the anthropometric and polysomnographic parameters correlated with objective compliance with mean wearing time (Table 3). No correlation was found between objective compliance and ESS score or OAm efficacy in terms of AHI reduction. However, a significant inverse correlation was found between objective compliance at 3 months’ follow-up and posttreatment VAS values for snoring (P = .006; ρ = –0.40) (Figure 3). Objective compliance correlated significantly with a more pronounced decrease in socially disturbing snoring as reported by the partner compared with baseline VAS scores for snoring without the OAm (P = .005; ρ = 0.39) (Figure 3).

In patients who never or rarely experienced adverse effects, median objective compliance at the 1-month follow-up was 7.10 hours per night (range, 5.85-7.61 hours per night) compared with 5.81 hours per night (range, 4.66-7.34 hours per night) in patients who occasionally, often, or always experienced one of the adverse effects mentioned. However, this difference was not statistically significant. At 3 months’ follow-up, median objective compliance was 6.73 hours per night (range, 5.85-7.27 hours per night) in patients who did not experience adverse effects and 6.42 hours per night (range, 4.42-7.20 hours per night) in patients who experienced some adverse effects. The presence of dry mouth was the only adverse effect that correlated with objective compliance at 3 months’ follow-up, with the infrequent occurrence of xerostomia leading to higher compliance (P < .05; ρ = –0.31).

According to a multiple linear model for the objective mean wearing time at the 3-month follow-up, including baseline VAS score for snoring, ESS score, AHI, age, BMI, sex, decrease in VAS score for snoring, decrease in ESS score, decrease in AHI, and the presence of adverse effects, a decrease in VAS score for snoring and a lower baseline AHI were predictors of higher objective mean wearing time (P = .003 for decrease in VAS score for snoring and P = .03 for baseline AHI; R2 = 0.24).

Discussion

This study evaluated possible correlations between objective compliance and patients’ anthropometric characteristics, polysomnographic parameters, and subjective reports of snoring, daytime sleepiness, and adverse effects. Neither the anthropometric and polysomnographic parameters nor excessive daytime sleepiness correlated with compliance in a group of patients with, on average, mild sleep apnea. The only 2 parameters that correlated with higher objective compliance during OAm therapy were a more pronounced decrease in reports of snoring and the presence of dry mouth.

Objective compliance was analyzed in 51 patients with a median compliance of 6.2 hours per night (range, 5.1-7.4 hours per night) at 1 month and 6.4 hours per night (range, 4.7-7.2 hours per night) at 3 months. In addition, the patients used their appliance almost every night: 93.1% (range, 77.5%-100%) of the nights at 1 month and 92.2% (range, 73.6%-98.4%) of the nights at 3 months. The compliance rate was 82% at both 1 and 3 months, with a regular user rate of 73% and 71%, respectively. This compliance rate is lower than that reported in the literature,27,28 although still relatively high.

There have been previous studies on subjective compliance and tolerability of OAm therapy29,30: disease severity, age, sex, and excessive daytime sleepiness did not correlate with poor compliance during OAm therapy. Our results based on objective compliance data also confirmed that baseline polysomnographic and anthropometric data and reports of excessive daytime sleepiness did not correlate with lower compliance in a group of patients with, on average, mild sleep apnea.

In the literature, patients who are satisfied with the effect of the OAm on their sleep apnea symptoms have a higher compliance rate than patients who are not satisfied with the effect of the OAm on their symptoms.36 Therefore, the most important finding of our study is that patients who subjectively experienced a greater improvement in their snoring as reported by their partner exhibited a higher objective mean wearing time. Indeed, snoring is often the patients’ major symptom and, therefore, most often the principal reason to seek medical help.37 A reduction in snoring is perceived by patients as therapeutic efficacy and therefore favors the use of the OAm, thereby improving compliance.

Another common reason for OAm discontinuation described in the literature is the presence of self-perceived adverse effects.29,30 However, in our study, no OAm discontinuation was reported, at least for the patients who returned for the 3-month follow-up visit. The results of this study therefore could not confirm the previous results that the discontinuation rate is correlated with self-perceived adverse effects.29,30 A possible explanation for the low discontinuation rate in our study could be the recent advances in the technology and comfort of OAm devices.38 Another reason for the low discontinuation rate could be the intense patient management at our multidisciplinary clinic.39 It is known that most adverse effects caused by OAm therapy are mild and transient,40 occur during the initial phase of OAm therapy, and tend to resolve with time.29 If physicians are aware of the importance of early management of adverse effects, the patients will be motivated and encouraged to become accustomed to the OAm. In this study, a relatively low number of adverse effects was reported by the patients, and the reported adverse effects were rather mild, with an occurrence of rarely to never. In a patient population with more reported adverse effects, the presence of these adverse effects might be a determinant of low compliance or even discontinuation of therapy, as is reported in previous studies relying on subjective compliance data.29,30

At 1 month of follow-up, objective compliance was more than 1 hour per night higher in patients who reported no or rarely occurring adverse effects: 7.10 hours per night (range, 5.85-7.61 hours per night) compared with 5.81 hours per night (range, 4.66-7.34 hours per night) in patients with self-perceived adverse effects. Although this difference was not statistically significant, a difference in compliance of more than 1 hour is considered clinically relevant. This difference in use disappeared at 3 months’ follow-up. In addition, at 3 months’ follow-up, the only adverse effect that correlated with the objective mean wearing time in hours per night was a self-perceived dry mouth. Recent studies have shown that better compliance with therapy can be achieved with an intensive follow-up program, including thorough patient education, detailed explanation of the treatment itself, and management of adverse effects.41,42 Long-term persistence of adverse effects lead to discontinuation of treatment.38 In a study on compliance during CPAP therapy, nightly use increased by 1.7 hours on average with multidimensional intervention and follow-up.42 There is little reason to think that an identical approach in OAm therapy will not benefit patients receiving OAm therapy.

Conclusions

In this study, a more pronounced decrease in socially disturbing snoring during OAm therapy was significantly correlated with better compliance. In addition, the presence of dry mouth correlated with lower compliance. These results highlight the importance of the effect of the cardinal symptom of snoring on therapeutic compliance during OAm therapy.

Back to top
Article Information

Submitted for Publication: April 29, 2015; final revision received June 20, 2015; accepted July 23, 2015.

Corresponding Author: Marijke Dieltjens, MBS, PhD, Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Prinsstraat 13, 2000 Antwerp, Belgium (marijke.dieltjens@uantwerpen.be).

Published Online: September 24, 2015. doi:10.1001/jamaoto.2015.1756.

Author Contributions: Drs Dieltjens and Verbruggen had full access to all the data in the study and take responsibility for the integrity of the data and the accuracy of the data analyses. They contributed equally to the study.

Study concept and design: Braem, De Backer, Van de Heyning, Vanderveken.

Acquisition, analysis, or interpretation of data: Dieltjens, Verbruggen, Braem, Wouters, Verbraecken, Hamans, Van de Heyning, Vanderveken.

Drafting of the manuscript: Dieltjens, Verbruggen, Braem, De Backer, Vanderveken.

Critical revision of the manuscript for important intellectual content: Dieltjens, Verbruggen, Braem, Wouters, Verbraecken, Hamans, Van de Heyning, Vanderveken.

Statistical analysis: Dieltjens, Verbruggen, Wouters, Vanderveken.

Obtained funding: Van de Heyning.

Administrative, technical, or material support: Verbruggen, Braem, Verbraecken, De Backer.

Study supervision: Braem, Verbraecken, Hamans, Van de Heyning, Vanderveken.

Conflict of Interest Disclosures: Dr Hamans reported serving as a consultant for Philips Electronics B.V. Dr Vanderveken reported receiving a research grant from SomnoMed Ltd and serving as co-investigator for a study supported by Inspire Medical Systems Inc and as a consultant for Inspire Medical Systems Inc and Philips Electronics B.V.

References
1.
Malhotra  A, White  DP.  Obstructive sleep apnoea. Lancet. 2002;360(9328):237-245.
PubMedArticle
2.
Anstead  M, Phillips  B.  The spectrum of sleep-disordered breathing. Respir Care Clin N Am. 1999;5(3):363-377, viii.
PubMed
3.
Peppard  PE, Young  T, Barnet  JH, Palta  M, Hagen  EW, Hla  KM.  Increased prevalence of sleep-disordered breathing in adults. Am J Epidemiol. 2013;177(9):1006-1014.
PubMedArticle
4.
 Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research: the report of an American Academy of Sleep Medicine Task Force. Sleep. 1999;22(5):667-689.
PubMed
5.
Collop  NA.  Obstructive sleep apnea syndromes. Semin Respir Crit Care Med. 2005;26(1):13-24.
PubMedArticle
6.
Guilleminault  C, Tilkian  A, Dement  WC.  The sleep apnea syndromes. Annu Rev Med. 1976;27:465-484.
PubMedArticle
7.
Tkacova  R, Dorkova  Z. Clinical Presentations of OSA in Adults: European Respiratory Society Monograph. Norwich, UK: European Respiratory Society; 2010:86-103.
8.
Vanderveken  OM, Boudewyns  A, Ni  Q,  et al.  Cardiovascular implications in the treatment of obstructive sleep apnea. J Cardiovasc Transl Res. 2011;4(1):53-60.
PubMedArticle
9.
Marin  JM, Carrizo  SJ, Vicente  E, Agusti  AG.  Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. 2005;365(9464):1046-1053.
PubMedArticle
10.
Bradley  TD, Floras  JS.  Obstructive sleep apnoea and its cardiovascular consequences. Lancet. 2009;373(9657):82-93.
PubMedArticle
11.
Yaggi  HK, Concato  J, Kernan  WN, Lichtman  JH, Brass  LM, Mohsenin  V.  Obstructive sleep apnea as a risk factor for stroke and death. N Engl J Med. 2005;353(19):2034-2041.
PubMedArticle
12.
Somers  VK, White  DP, Amin  R,  et al.  Sleep apnea and cardiovascular disease: an American Heart Association/American College of Cardiology Foundation scientific statement from the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on Clinical Cardiology, Stroke Council, and Council on Cardiovascular Nursing. J Am Coll Cardiol. 2008;52(8):686-717.
PubMedArticle
13.
Epstein  LJ, Kristo  D, Strollo  PJ  Jr,  et al; Adult Obstructive Sleep Apnea Task Force of the American Academy of Sleep Medicine.  Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med. 2009;5(3):263-276.
PubMed
14.
Sullivan  CE, Issa  FG, Berthon-Jones  M, Eves  L.  Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares. Lancet. 1981;1(8225):862-865.
PubMedArticle
15.
Kushida  CA, Littner  MR, Hirshkowitz  M,  et al; American Academy of Sleep Medicine.  Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. Sleep. 2006;29(3):375-380.
PubMed
16.
Phillips  CL, Grunstein  RR, Darendeliler  MA,  et al.  Health outcomes of continuous positive airway pressure versus oral appliance treatment for obstructive sleep apnea: a randomized controlled trial. Am J Respir Crit Care Med. 2013;187(8):879-887.
PubMedArticle
17.
Vanderveken  OM.  Perspectives on the reduction in cardiovascular mortality with oral appliance therapy for patients with severe obstructive sleep apnoea intolerant to continuous positive airway pressure. Respirology. 2013;18(8):1161-1162.
PubMedArticle
18.
Marklund  M, Verbraecken  J, Randerath  W.  Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy. Eur Respir J. 2012;39(5):1241-1247.
PubMedArticle
19.
Tsuiki  S, Lowe  AA, Almeida  FR, Kawahata  N, Fleetham  JA.  Effects of mandibular advancement on airway curvature and obstructive sleep apnoea severity. Eur Respir J. 2004;23(2):263-268.
PubMedArticle
20.
Ng  A, Gotsopoulos  H, Darendeliler  AM, Cistulli  PA.  Oral appliance therapy for obstructive sleep apnea. Treat Respir Med. 2005;4(6):409-422.
PubMedArticle
21.
Clark  GT, Arand  D, Chung  E, Tong  D.  Effect of anterior mandibular positioning on obstructive sleep apnea. Am Rev Respir Dis. 1993;147(3):624-629.
PubMedArticle
22.
Ravesloot  MJ, de Vries  N.  Reliable calculation of the efficacy of non-surgical and surgical treatment of obstructive sleep apnea revisited. Sleep. 2011;34(1):105-110.
PubMed
23.
Kribbs  NB, Pack  AI, Kline  LR,  et al.  Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis. 1993;147(4):887-895.
PubMedArticle
24.
Pépin  JL, Krieger  J, Rodenstein  D,  et al.  Effective compliance during the first 3 months of continuous positive airway pressure: a European prospective study of 121 patients. Am J Respir Crit Care Med. 1999;160(4):1124-1129.
PubMedArticle
25.
Krieger  J, Kurtz  D.  Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome. Eur Respir J. 1988;1(5):436-438.
PubMed
26.
Grote  L, Hedner  J, Grunstein  R, Kraiczi  H.  Therapy with nCPAP: incomplete elimination of sleep related breathing disorder. Eur Respir J. 2000;16(5):921-927.
PubMedArticle
27.
Vanderveken  OM, Dieltjens  M, Wouters  K, De Backer  WA, Van de Heyning  PH, Braem  MJ.  Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing. Thorax. 2013;68(1):91-96.
PubMedArticle
28.
Dieltjens  M, Braem  MJ, Vroegop  AV,  et al.  Long-term objective compliance measurement during oral appliance therapy in patients with sleep-disordered breathing: 1 year follow-up [abstract 0408]. Sleep. 2012;35(suppl):A141-A142.
29.
de Almeida  FR, Lowe  AA, Tsuiki  S,  et al.  Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome. J Clin Sleep Med. 2005;1(2):143-152.
PubMed
30.
Marklund  M, Franklin  KA.  Long-term effects of mandibular repositioning appliances on symptoms of sleep apnoea. J Sleep Res. 2007;16(4):414-420.
PubMedArticle
31.
Marklund  M, Stenlund  H, Franklin  KA.  Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Chest. 2004;125(4):1270-1278.
PubMedArticle
32.
Dieltjens  M, Vanderveken  OM, Hamans  E,  et al.  Treatment of obstructive sleep apnea using a custom-made titratable duobloc oral appliance: a prospective clinical study. Sleep Breath. 2013;17(2):565-572.
PubMedArticle
33.
Schott  TC, Göz  G.  Applicative characteristics of new microelectronic sensors Smart Retainer and TheraMon for measuring wear time. J Orofac Orthop. 2010;71(5):339-347.
PubMedArticle
34.
Johns  MW.  A new method for measuring daytime sleepiness: the Epworth Sleepiness Scale. Sleep. 1991;14(6):540-545.
PubMed
35.
Vanderveken  OM, Devolder  A, Marklund  M,  et al.  Comparison of a custom-made and a thermoplastic oral appliance for the treatment of mild sleep apnea. Am J Respir Crit Care Med. 2008;178(2):197-202.
PubMedArticle
36.
McGown  AD, Makker  HK, Battagel  JM, L’Estrange  PR, Grant  HR, Spiro  SG.  Long-term use of mandibular advancement splints for snoring and obstructive sleep apnoea: a questionnaire survey. Eur Respir J. 2001;17(3):462-466.
PubMedArticle
37.
Woodson  BT, Han  JK.  Relationship of snoring and sleepiness as presenting symptoms in a sleep clinic population. Ann Otol Rhinol Laryngol. 2005;114(10):762-767.
PubMedArticle
38.
Sutherland  K, Vanderveken  OM, Tsuda  H,  et al.  Oral appliance treatment for obstructive sleep apnea: an update. J Clin Sleep Med. 2014;10(2):215-227.
PubMed
39.
Ten Berge  DM, Braem  MJ, Altenburg  A,  et al.  Evaluation of the impact of a clinical pathway on the organization of a multidisciplinary dental sleep clinic. Sleep Breath. 2014;18(2):325-334.
PubMedArticle
40.
Ferguson  KA, Cartwright  R, Rogers  R, Schmidt-Nowara  W.  Oral appliances for snoring and obstructive sleep apnea: a review. Sleep. 2006;29(2):244-262.
PubMed
41.
Basoglu  OK, Midilli  M, Midilli  R, Bilgen  C.  Adherence to continuous positive airway pressure therapy in obstructive sleep apnea syndrome: effect of visual education. Sleep Breath. 2012;16(4):1193-1200.
PubMedArticle
42.
Bouloukaki  I, Giannadaki  K, Mermigkis  C,  et al.  Intensive versus standard follow-up to improve continuous positive airway pressure compliance. Eur Respir J. 2014;44(5):1262-1274.
PubMedArticle
×