Intramuscularly Administered Krypton Clathrate Kr 85Measurement of Acute Changes in Regional Blood Flow

Author Affiliations

Boston; Cambridge, England; Boston
From the Fifth (Harvard) Surgical Service, Boston City Hospital (Dr. Schuler); the Cambridge (England) University Medical School (Dr. Slapak); and the Harvard Medical Unit, Boston City Hospital (Dr. Ransil).

Arch Surg. 1973;107(6):895-898. doi:10.1001/archsurg.1973.01350240061017
Abstract

Intramuscularly administered isotope is used in determining regional blood flow. The purpose of the experiment is to determine whether acute occlusion of the femoral artery or vein can be detected by the washout technique. Control washout times are obtained in the hind legs of rats after which either the femoral artery or vein is ligated and the disappearance curves of intramuscularly administered, krypton clathrate Kr 85 are determined.

Occlusion of either the artery or vein can be detected reliably by a prolonged half-time of the krypton clathrate Kr 85 washout. Although the group with vein obstruction could be distinguished from the arterial occlusion group, determination of the kind of block on the basis of a single injection is unreliable because of the overlap of the two groups.

References
1.
Kety S:  Measurement of regional circulation by the local clearance of radioactive sodium . Am Heart J 38:321-328, 1949.Article
2.
Holzman GB, et al:  Measurement of muscle blood flow in the human forearm with radioactive krypton and xenon . Circulation 30:27-34, 1964.Article
3.
Lindbjerg IF:  Leg muscle blood-flow measured with 133xenon after ischaemia periods and after muscular exercise performed during ischaemia . Clin Sci 30:399-407, 1966.
4.
Lindbjerg IF:  Routine use of the xenon-133 clearance method in peripheral circulation studies, with special regard to its correlation to angiography . Scand J Clin Lab Invest 19( (suppl 99) ):123-129, 1967.
5.
Siggaard-Andersen J, et al:  Venous occlusion plethysmography and Xe133 clearance compared as to diagnostic value . Vasc Dis 4:251-257, 1967.
6.
Dahn I, Lassen NA, Westling H:  Blood flow in human muscles during external pressure of venous stasis . Clin Sci 32:467-473, 1967.
7.
Lassen NA, Lindbjerg IF, Munck O:  Measurement of blood-flow through skeletal muscle by intramuscular injection of xenon-133 . Lancet 1:686-689, 1964.Article
×