[Skip to Content]
Sign In
Individual Sign In
Create an Account
Institutional Sign In
OpenAthens Shibboleth
[Skip to Content Landing]
Article
March 1989

Fibrin Glue Achieves Hemostasis in Patients With Coagulation Disorders

Author Affiliations

From the Department of Surgery, Martin Luther King, Jr-Charles R. Drew Medical Center, Los Angeles, and the UCLA School of Medicine.

Arch Surg. 1989;124(3):385-387. doi:10.1001/archsurg.1989.01410030135023
Abstract

• Fibrin glue (FG), made with highly concentrated human fibrinogen and clotting factors, was used to achieve parenchymal organ hemostasis in patients with disordered coagulation secondary to massive transfusion, chronic disease, and disseminated intravascular coagulation; it was effective in controlling liver hemorrhage in seven patients and in the performance of a splenorrhaphy in one other patient. The coagulation profile was grossly abnormal in all patients, and the mean ±SD intraoperative blood loss was 5.1 ±4.2 L; patients received 14± 10 U of blood perioperatively. The amount of FG required to achieve hemostasis varied directly with the extent of injury and intraoperative blood loss (r=.84), and all patients with a blood loss greater than 4 L required at least 25 mL of FG to stop bleeding. Two patients died postoperatively secondary to cardiac arrest and adult respiratory distress syndrome. Because FG does not depend on adequate platelet or clotting factor levels to be effective, it is especially useful in patients with parenchymal organ hemorrhage and disordered coagulation.

(Arch Surg 1989;124:385-387)

References
1.
String T, Robinson AJ, Blaisdell FW:  Massive trauma: Effect of intravascular coagulation on prognosis . Arch Surg 1971;102:406-411.Article
2.
Phillips TF, Soulier G, Wilson RF:  Outcome of massive transfusion exceeding two blood volumes in trauma and emergency surgery . J Trauma 1987;27:903-910.Article
3.
Redl H, Schlag G, Dinges H, et al:  Background and methods of 'fibrin sealing,'  in Winter GD, Gibbons DF, Plenk H (eds): Biomaterials . New York, John Wiley & Sons Inc, 1982, pp 669-696.
4.
Kram HB, Shoemaker WC, Hino ST, et al:  Splenic salvage using biologic glue . Arch Surg 1984;119:1309-1311.Article
5.
Kram HB, Reuben BI, Fleming AW, et al:  Use of fibrin glue in hepatic trauma . J Trauma 1987;27:825.
6.
Kram HB, Shoemaker WC, Hino ST, et al:  Tracheal repair with fibrin glue . J Thorac Cardiovasc Surg 1985;90:771-775.
7.
Kram HB, Garces MA, Klein SR, et al:  Common bile duct anastomosis using fibrin glue . Arch Surg 1985;120:1250-1256.Article
8.
Kram HB, Nugent P, Reuben BI, et al: Fibrin glue sealing of polytetrafluoroethylene (PTFE) vascular graft anastomoses: Comparison with oxidized cellulose. J Vasc Surg, in press.
9.
Guttmen T: Untersuchungen eines Fibrinklebers fur die Anwendung in der shirugie periper Nerven: Diplomarkiet Inst F Botanik, technische mikroscopie Organ: Rohstofflehre . Vienna, Technische Universität Wien, 1978.
10.
Morgenstern L:  Microcrystalline collagen used in experimental splenic injury: A new surface hemostatic agent . Arch Surg 1974;109:44-47.Article
×