Article
June 1989

Preliminary Clinical Experience With the Titanium Greenfield Vena Caval Filter

Author Affiliations

From the Departments of Surgery (Dr Greenfield) and Radiology (Dr Cho), the University of Michigan Medical Center, Ann Arbor; the University of Maryland, Baltimore (Dr Pais); and Ohio State University, Columbus (Dr Van Aman).

Arch Surg. 1989;124(6):657-659. doi:10.1001/archsurg.1989.01410060019002
Abstract

• Preliminary clinical experience in 40 patients from three institutions is reported for a new titanium model of the Greenfield vena caval filter. The titanium filter is slightly larger than the standard stainless steel filter and can be loaded into a 12 F diameter carrier system as opposed to the 24 F stainless steel filter. In patients ranging from 17 to 94 years of age, percutaneous insertions were made from the right femoral vein in 24 patients, the left femoral vein in 11 patients, and the right internal jugular in 2 patients. Operative access was obtained in 1 patient each from the right femoral, right jugular, and a lumbar vein at laparotomy. Insertion was completed in all cases but 1 and only 1 patient (3%) showed postoperative femoral vein thrombosis. Distal filter migration was seen in 3 cases (7.5%) without sequelae, and there was no proximal migration. The titanium Greenfield vena caval filter provides improved ease of insertion, and the sheath technique should prevent misplacement. Distal migration should be preventable by techniques to promote hook engagement at the time of insertion.

(Arch Surg. 1989;124:657-659)

References
1.
Greenfield LJ, Michna BA.  Twelve-year clinical experience with the Greenfield vena caval filter . Surgery . 1988;104:706-712.
2.
Wingerd M, Bernhard VM, Maddison F, Towne JB.  Comparison of caval filters in the management of venous thromboembolism . Arch Surg . 1978; 113:1264-1271.Article
3.
Chimochowski GE, Evans RH, Zarins CK, Lu CT, DeMeester TR.  Greenfield filter versus Mobin-Uddin umbrella: the continuing quest for the ideal method of vena caval interruption . J Thorac Cardiovasc Surg . 1980; 79:358-365.
4.
Stewart JR, Peyton JWR, Crute SL, Greenfield LJ.  Clinical results of suprarenal placement of the Greenfield vena cava filter . Surgery . 1982;92:1-4.
5.
Orsini RA, Jarrell BE.  Suprarenal placement of vena caval filters: indications, techniques and results . J Vasc Surg . 1984;1:124-135.Article
6.
Tadavarthy SM, Castaneda-Zuniga W, Salamonowitz E, et al.  Kimray-Greenfield filter: percutaneous introduction . Radiology . 1984;151:525-526.Article
7.
Kantor A, Glanz S, Gordon DH, Sclafani SJA.  Percutaneous insertion of the Kimray-Greenfield filter: incidence of femoral vein thrombosis . Am J Res . 1987;1065-1066.
8.
Burke PE, Michna BA, Harvey CF, Crute SL, Sobel M, Greenfield LJ.  Experimental comparison of percutaneous vena caval devices: titanium Greenfield filter versus bird's nest filter . J Vasc Surg . 1987;6:66-70.Article
9.
Greenfield LJ, Savin MA. Comparison of titanium and stainless steel Greenfield vena caval filters. Surgery. In press.
10.
Hoffman MJ, Greenfield LJ.  Central venous septic thrombosis managed by superior vena cava Greenfield filter and venous thrombectomy: a case report . J Vasc Surg . 1986;4:606-611.Article
11.
Greenfield LJ, Stewart JR, Crute SL.  Improved technique for Greenfield vena caval filter insertion . Surg Gynecol Obstet . 1983;156:217-219.
12.
Berland LL, Maddison FE, Bernhard VM.  Radiologic follow-up on vena cava filter devices . Am J Res . 1980;134:1047-1052.
13.
Gomez GA, Cutler BS, Wheeler HB.  Transvenous interruption of the inferior vena cava . Surgery . 1983;93:612-619.
14.
Messmer JM, Greenfield LJ.  Greenfield caval filters: long term radiographic follow-up study . Radiology . 1985;156:613-618.Article
15.
Castaneda F, Herrera M, Cragg AH, et al.  Migration of a Kimray-Greenfield filter to the right ventricle . Radiology . 1983;149:690.Article
×