Importance Implantable cardioverter-defibrillators (ICDs) have changed the way in which patients with chronic ventricular dysfunction are evaluated and treated.
Objective To examine patient-physician communication at the time the decision is made to implant an ICD.
Design, Setting, and Participants Forty-one patients with ICDs and 11 cardiologists were recruited by a national marketing research company for a study comprising patient focus groups and standardized patient interviews in 3 different metropolitan areas.
Interventions Eight patient focus groups and (separately) 22 standardized patient interviews with cardiologists.
Main Outcome Measures Patient focus group findings and the results of standardized patient interviews (each cardiologist interviewed 2 patients).
Results The mean (SD) patient age was 61.4 (14.7) years; 21 were female. Thirty-three patients could not recall a discussion about periprocedural or long-term complications. On a scale of 1 to 10, the mean (SD) rating of the degree to which patients felt informed before the implant procedure was 5.7 (3.2) (1 indicates “not at all informed,” and 10 indicates “I had all the information I needed or wanted”). The mean (SD) estimated number of patients out of 100 who would be saved by the ICD was 87.9 (20.1). A negative perception on body image and lifestyle was prevalent. Across 22 standardized patient interviews, cardiologists frequently (in >17 of 22 of interviews) did not address or minimized or denied quality-of-life issues and long-term consequences of ICD placement, including the risk for depression, anxiety, and inappropriate delivery of shock or device advisory. In 15 of 22 of the standardized patient interviews, cardiologists used unexplained medical terms or jargon.
Conclusions and Relevance Patient-physician communication about ICDs is characterized by unclear representation and omission of information to patients, with notable lack of attention to psychological and long-term risks. Training of cardiologists on information exchange with patients may promote informed decision making and preempt threats to patient quality of life.
I learned a long time ago that minor surgery is when they do the operation on someone else, not you.—Bill Walton (http://www.quotegarden.com/medical.html)
The introduction of transvenous cardioverter-defibrillators (ICDs) has changed the way in which patients with chronic ventricular dysfunction are evaluated and treated.1-3 Historically, sudden death risk assessment strategies failed to accurately stratify patients. As a consequence, asymptomatic patients often receive ICDs as part of a primary prevention strategy,4 despite the potential for postimplantation complications,5-7 including anxiety and other psychosocial sequelae.8,9 Furthermore, significant numbers of recipients have advanced age or comorbidities that serve as competing risks for mortality.10,11 However, few studies12,13 have addressed information exchange between physicians and patients on pertinent issues such as risk vs benefit and potential consequence for quality of life.
Consequently, we conducted focus groups composed of patients with ICDs to address the nature of preimplantation discussions. Separately, we observed communication content and style of cardiologists using standardized patient (SP) interviews designed to further evaluate communication about the ICD decision process.
Patient focus groups were designed to explore (1) the effect of ICD placement and downstream events on patient acceptance of the device, (2) the patient's evaluation of communication about risks and benefits during preimplantation discussions, and (3) patient expectations. Eight patient focus groups convened at midwestern and northeastern suburban and urban locations. Patients were recruited by a national health care marketing research company. Screening questions were designed to identify patients who had not experienced a sudden death event before ICD placement and to ensure that not more than 1 patient was drawn from the same cardiology practice. Patients gave verbal consent to participate and received an honorarium for participation.
A topic guide was used to structure discussions, which were scheduled to last approximately 120 minutes. Patients were asked to rate the degree to which they felt informed before the implant procedure and to estimate the number of patients of 100 who would be saved by the ICD. Patients were queried about a range of ICD-related experiences. Patient focus groups were audio recorded, and the tapes were searched for commonalities and differences in descriptions of those experiences. Focus group composition was adequate to identify frequent and infrequent experiences among patients.14-19
One member of the research team (E.S.A.) facilitated all patient focus groups. Two other researchers (P.J.H. and J.T.C.) reviewed the patient focus group discussions for a priori themes derived from clinical experience and a literature review and extracted primary themes based on recurrent content, amount of group discussion time, consistency across group participants, and participant-perceived degree of importance. The resulting index of themes was independently reviewed and verified by the moderator (E.S.A.); themes identified by only one observer were discussed until group consensus was reached about their relative importance.
Standardized patient interviews
Four primary methods have been used to study patient-physician communication, including SPs, surveys of physicians and patients, written and video vignettes, and direct observation of actual visits. Standardized patients were used in this study because they can portray complex clinical conditions, while controlling for patient characteristics and behavior, thereby reducing unwanted variability in the patient presentation.20-25
Twelve cardiologists were recruited from 2 urban areas (the Midwest and the South) who were primary decision makers for ICD placement in at least 10 patients per year. Each cardiologist interviewed 2 SPs.
One SP portrayed a 61-year-old white man with ischemic heart disease and symptoms of moderate heart failure; the other SP portrayed a 31-year-old African American woman with postpartum cardiomyopathy, persistent ventricular dysfunction, and recent hospitalization for heart failure (eAppendix 1). Both were taking medications congruent with published guidelines26 and were candidates for ICD placement based on criteria from randomized controlled trials that formed the basis for regulatory approval. The SPs were extensively trained from a standardized script about symptoms, presentation, and prognosis for their respective conditions and were educated about ICD indications and function. Mock SP interviews with feedback and retraining were performed before the cardiologist encounters. Standardized patients were instructed to allow reasonable time for cardiologists to initiate discussion of quality-of-life and risk issues; if a cardiologist did not initiate such discussions, the SP could initiate them.
Using scripted instructions, a researcher (P.J.H. or E.S.A.) informed the cardiologists about the objective of the session, namely, to evaluate patient-physician decision-making processes. Cardiologists were encouraged to interact as though the SPs were typical patients. The interview order was kept constant, with the male SP first and the female SP second. No research personnel were present during the SP interviews, but cardiologists were aware that interviews were being videotaped and observed through a mirrored window.
To analyze the SP interviews, a data abstraction tool (eAppendix 2) was developed and used independently by each research team rater to code the following: (1) occurrences of interview events (eg, medical history, description of the implant procedure, use of unexplained medical terms, statements of implantation benefits, and expressions of empathy), (2) ratings of strength of psychosocial inquiry and empathy (1 indicates low, 2 indicates moderate, and 3 indicates high), (3) initiator (cardiologist or SP) of a discussion, (4) quotations that exemplified an issue, (5) interview duration, and (6) time to first mention of a quality-of-life issue, in an effort to understand its hierarchical importance. The use of analogy by the cardiologist to describe the ICD (eg, safety net) was also coded. The study was approved by the Saint Louis University Institutional Review Board.
The 41 patient focus group participants (21 women and 20 men) had a mean (SD) age of 61.4 (14.7) years. Almost 40% (n = 16) of the patients were 70 years or older; 22% (n = 9) were younger than 50 years. Dates of initial ICD placement were as follows: before 2000 (n = 3), 2000 to 2002 (n = 5), 2003 to 2005 (n = 8), 2006 to 2008 (n = 10), and 2009 to 2011 (n = 15).
Precise indications for implantation were difficult to assess. Among 14 patients who knew their precise history, 12 underwent implantation for primary prevention. Most patients seemed to have ischemic cardiomyopathy, but 5 patients had uncommon underlying conditions, including congenital heart disease, long QT syndrome, and familial, hypertrophic, or Takotsubo cardiomyopathy. Twenty patients (49%) had experienced 2 or more device procedures (upgrade, revision, or generator replacement), 8 on the basis of a device recall or an advisory.
Thirty-three patients (80%) did not report discussing periprocedural risks or potential long-term complications (Table 1); the concept of device malfunction was new to some patients. Generally, patients recalled that physicians presented the ICD option in absolute terms.
Patients estimated the degree to which they felt informed before the implant procedure on a scale of 1 to 10 (1 indicates “not at all informed,” and 10 indicates “I had all the information I needed or wanted”). The mean (SD) rating for 39 patients was 5.7 (3.2); at the time of the implant procedure and during the patient focus group meeting, 2 patients indicated little interest in detailed knowledge of risks. The mean (SD) estimated number of patients out of 100 who would be saved by the ICD was 87.9 (20.1).
Content of Preimplantation Discussion
Patients recalled that discussions of quality-of-life issues were limited in scope and were often characterized by physician statements that the ICD would have no lifestyle effect. No participants reported administration of a quality-of-life instrument before or after implantation. Preimplantation mention of the possibility of depression, anxiety, or other emotional impact was infrequent.
Quality of Preimplantation Discussion
Participants reported that most interactions were brief. Those who were hospitalized at the time of initial discussion noted that decisions were made quickly, with little time provided to understand the implications; few participants recalled that they were offered time to think about it at home. Older participants frequently mentioned that they deferred the decision to family members.
Effect of ICD on Quality of Life
The effect of the ICD on daily activities such as routine physical labor was a major issue for multiple participants. Passing through security checkpoints at airports was a frequent topic; several patients stated that they no longer fly because they disliked the extra screening. For some, the ICD created a perceived social stigma, negatively influencing return to work. The implications for medical care were also noted, including interference with mammograms, inability to undergo magnetic resonance imaging, and changes in ICD programming that are required during surgical procedures.
Several participants cited early adjustment difficulties and sought counseling for anxiety and mood disturbance. Several were not convinced of the ongoing need for the ICD (“they could have done something [else]”). Concerns were raised about the influence on family members and the effect of the ICD on mode of death.
Multiple participants mentioned the effect on body image, reflecting the cosmetic change and physical discomforts associated with the ICD. Body discomfort included “pulling sensations,” discomfort lying on the side where the ICD was situated, and the interrogation process during routine follow-up visits. Patients also discussed the mechanical and electrical aspects of the ICD, indicating that these made them feel robotic. Nevertheless, participants frequently agreed that the ICD provided security. Many participants recalled that physicians stated the ICD was implanted “just in case,” and there was wide acceptance of this concept. Representative patient responses are given in Table 2.
Some patients initially thought of the ICD as a cure but realized shortly after implantation that this was not the case. There was near unanimity that they learned more about ICD risks and benefits after implantation than before implantation. The use of ancillary educational material before the implant procedure was limited.
Several areas of uncertainty in the postimplantation period were identified. These included (1) generator life, the procedure required to change the generator, and the frequency of generator changes; (2) the sensation of a shock, response to a shock, and concerns about occurrence during “bad times” such as when driving; (3) the effect on life extension; and (4) remote radio or telecommunication interference with ICD operation.
Standardized patient interviews
Before interviewing the SPs, one cardiologist expressed suspicion that the interview had ulterior motives and voiced concern that the project was designed by federal regulatory officials to entrap physicians about ICD prescribing practice. Despite assurances, this cardiologist would not directly address the ICD decision issue; these data were excluded from the final analyses.
Twenty-two SP interviews were analyzed. The mean (SD) duration was 23.5 (6.1) minutes. The cardiologists were predominantly male (n = 10) and in private practice (n = 10); their mean (SD) age was 51.0 (9.8) years. Professional categorizations were electrophysiologist (n = 1), invasive noninterventional cardiologist (n = 2), noninvasive cardiologist (n = 3), and interventional cardiologist (n = 5). Four of the cardiologists regularly implanted ICDs.
The interviews focused on issues of the SP's medical history and procedure-related processes in the context of stating the medical benefit of ICD placement (Table 3). Psychosocial history was obtained in 11 of 22 SP interviews; when present, the strength of the inquiry about psychosocial history was low, with a mean (SD) rating of 1.1 (0.3) on a scale of 1 to 3 (1 indicates low, and 3 indicates high). Unexplained medical terminology or jargon was frequently used by cardiologists (in more than two-thirds of SP interviews) (Table 4 and Table 5).
Cardiologist statements about the major benefit of ICD placement were simple and were generally reiterated during the SP interviews. The primary emphasis was the prevention of sudden death. No cardiologist discussed the epidemiological or clinical data on the prevalence of actual lifesaving ICD shocks, the prevalence of patients who ever require a shock, or the risk for death, despite ICD shock. Rather, positively valenced analogies were used to describe the purpose and operation of the ICD (Table 4).
Discussion of Effect on Quality of Life and Related Topics
The mean (SD) time to first mention of a quality-of-life issue was 12.2 (7.3) minutes, or about halfway through the SP interview. The mean (SD) time to first quality-of-life mention was longer when the discussion was initiated by the SP (14.5 [5.3] minutes) than when it was initiated by the cardiologist (8.4 [8.2] minutes) (P = .06). The most common quality-of-life issues referred to social functioning (Table 3) and usually were about limitations imposed by the ICD on airport security check-ins and magnetic resonance imaging. Other related issues were acknowledged in only 1 to 5 of the SP interviews, often pertaining to potential limitations on vigorous exercise, choice of profession, and feeling or seeing the ICD under the skin. Quality-of-life implications were minimized in 14 SP interviews.
The risk for anxiety was mentioned in one-third of the SP interviews (n = 7: minimized in 3, denied in 1, and initiated by a cardiologist in 3); depression was not mentioned by a cardiologist as a risk. Possible deactivation of the ICD at the end of life was addressed in 1 of 22 SP interviews.
Bleeding (11 of 22 [50%]) and infection (10 of 22 [45%]) were the most common periprocedural risks acknowledged by the cardiologists. Other risks, including ICD lead dislodgment (6 of 22 [27%] and pneumothorax (discussed without minimizing in 7 of 22 [32%]), were mentioned in less than one-third of the SP interviews. Risk statements tended to be responsive to SP queries and typically were minimized (eg, “there is always the possibility of complications with surgery”). In 2 SP interviews, the possibility of surgical risks was denied. Only one cardiologist in one interview mentioned the possibility of death with the implant procedure.
Long-term issues were acknowledged in 9 of 22 SP interviews (41%). These typically involved statements about the need for continual monitoring and possible damage to the ICD in the event of trauma. The risk for inappropriate shock was discussed in 15 of 22 SP interviews (68%) and was initiated by the cardiologist in 7 of 15 cases (47%); however, when noted, the risk was minimized in 11 of 15 interviews (73%). Several statements of minimization and denial are listed in Table 5.
The need for ICD generator replacement was mentioned in 10 of 22 SP interviews (45%) (initiated by the cardiologist in 6 of 10 cases). The possibility of ICD recall was mentioned in 6 interviews and was typically initiated by the SP (in 5 of 6 cases).
Some expression of empathy occurred in more than half (12 of 22) of the SP interviews but tended to be cursory. On a scale of 1 to 3, the mean (SD) empathy rating was 1.5 (0.8). Expressions of empathy included the following: “I want you to have hope,” “I want you to be around for a long time,” “We want to make the decision that is right for you,” and “I know this sounds scary, but. . .”
Clinical trials of ICDs in the primary prevention cohort demonstrate a 5% to 7% absolute mortality reduction among patients with implanted devices over a period of 2 to 4 years.27 Several clinical variables such as advanced heart failure symptoms and renal failure have been shown to moderate survival benefit.3,28-32 In addition, potential complications have been described, including product advisories33 and infection and inappropriate ICD discharges.34 As reported in clinical trials,35-37 the experience of a shock is a distinguishing feature for patients and has been associated with diminished psychological functioning and quality of life. According to Sears et al,38,39 health care providers report that 15% of ICD recipients experience diminished quality of life after implantation, and 10% to 20% note diminished emotional functioning and strained family relationships. Previous investigations have identified problems with patient anxiety,40 sexual function,41 family dynamics,42 coping and adjustment,42-45 satisfaction within psychological-spiritual domains,46 and knowledge base.47,48 These observations should have relevance to the selection of patients for ICD placement and management; nevertheless, results of studies13,49 indicate that patients are uninformed and overly optimistic about expectations for the future.
Our data provide further insight into the patient experience. We obtained data from a diverse group of patients who gave a consistent message about the inadequacy of information shared before the implant procedure and inattention to psychosocial issues following the implantation. Many patients described ICD-related effects on body image and lifestyle. In cases where the ICD need was deemed urgent, most patients reported feeling overwhelmed by the pace of decision making. Many patients struggled with competing views of the ICD, seeing it as a safety net and as a source of physical and emotional discomfort.
Our findings are consonant with other studies50,51 that have focused on patient perceptions of physician communication about ICD management at the end of life. For example, Kirkpatrick et al51 found that 96% of 278 patients surveyed had never discussed with a medical practitioner what to do with their ICD if faced with an end-of-life situation. In addition, the “anthropomorphism” of the ICD, a concept described by Goldstein et al,52 was shared by a large percentage of patients in our focus groups and by almost every cardiologist in the SP interviews, who used words such as safety net and friend. As in one of the prior studies, patients “did not seem to fully comprehend the nuances and intricacies of these devices.”52(p11) Also consistent with prior research,13 our patients voiced optimistic estimates of ICD efficacy, likely reflecting physician minimization or denial of risks. Discussion of such key issues as the effect of the ICD on quality of life typically was prompted by SPs; without such prompting, many SP interviews would have ended without meaningful coverage of the topic. We posit that a lack of accurate information exchange can lead to patient uncertainty and may negatively influence quality of life.
We encountered several methodological challenges related to patient uncertainty about the indication for implantation and the actual type of device implanted. Because a combined ICD–biventricular pacemaker can affect heart failure symptoms, patient responses may be different than if an ICD alone is implanted. Focus groups bring together a heterogeneous collection of patients based on educational background, duration since implantation, history of a shock, and ability to distinguish real from phantom shocks,53 as well as other factors that might influence the risk for increasing psychological distress.54 In addition, our study was not powered to analyze the effect of key patient variables such as race/ethnicity or age. Nevertheless, patient responses on key questions were fairly uniform across focus groups.
Although the SP interview participants included cardiologists who implant ICDs and those who refer, the sample was too small to draw inferences about the influence of practice type, physician age, or other characteristics on quality of communication. Similarly, we cannot draw conclusions about the effect of the specific SP profiles because they differed by multiple characteristics, including age, sex, race/ethnicity, and underlying etiology of disease.
For future directions, it is important to develop and validate questions that can be used to identify patients who might be at risk for decrements in health-related quality of life following implantation. A greater focus on patient-physician communication is required. The content of such discussions needs to be more fully developed55; at the same time, the decision to implant an ICD is just one of multiple difficult discussions encountered in the contemporary care of patients with chronic and advanced heart disease. We hypothesize that communication skills can be taught in a formal educational initiative, with favorable effect on patients, as demonstrated in the oncology model.56
In summary, our study demonstrates that patient-physician communication about ICDs is characterized by patient misinformation and a lack of attention to psychosocial and long-term risks by the prescribing physician. Separate qualitative investigations with patients and cardiologists supported these conclusions. Given the high volume of ICD implant procedures, the present findings suggest that failure to fully engage patients in bidirectional communication may be widespread. Training of cardiologists about information exchange with patients may be beneficial to informed decision making and preempt threats to patient quality of life.
Correspondence: Paul J. Hauptman, MD, Department of Medicine, Saint Louis University School of Medicine, 3635 Vista Ave, St Louis, MO 63110 (hauptmpj@slu.edu).
Accepted for Publication: July 15, 2012.
Published Online: February 18, 2013. doi:10.1001/jamainternmed.2013.3171
Author Contributions: Each author had full access to all the data in the study and takes full responsibility for the integrity of the data and the accuracy of the data analysis. Study concept and design: Hauptman, Chibnall, and Armbrecht. Acquisition of data: Hauptman, Guild, and Armbrecht. Analysis and interpretation of data: Hauptman, Chibnall, and Armbrecht. Drafting of the manuscript: Hauptman, Chibnall, and Armbrecht. Critical revision of the manuscript for important intellectual content: Chibnall, Guild, and Armbrecht. Statistical analysis: Hauptman, Chibnall, and Armbrecht. Obtained funding: Hauptman. Administrative, technical, and material support: Hauptman, Chibnall, and Armbrecht. Study supervision: Hauptman.
Conflict of Interest Disclosures: None reported.
Funding/Support: This study was funded by the President's Research Fund and the Joseph C. Sansone Fund in Cardiovascular Outcomes Research, both at Saint Louis University.
Role of the Sponsors: The funding agencies had no role in the design and conduct of the study; collection, management, analysis, and interpretation of data; and preparation, review, or approval of the manuscript.
1.Epstein AE. Update on primary prevention implantable cardioverter-defibrillator therapy.
Curr Cardiol Rep. 2009;11(5):335-34219709493
PubMedGoogle ScholarCrossref 2.Moss AJ, Zareba W, Hall WJ,
et al; Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.
N Engl J Med. 2002;346(12):877-88311907286
PubMedGoogle ScholarCrossref 3.Bardy GH, Lee KL, Mark DB,
et al; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [published correction appears in
N Engl J Med. 2005;352(20):2146].
N Engl J Med. 2005;352(3):225-23715659722
PubMedGoogle ScholarCrossref 4.Nanthakumar K, Epstein AE, Kay GN, Plumb VJ, Lee DS. Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction: a pooled analysis of 10 primary prevention trials.
J Am Coll Cardiol. 2004;44(11):2166-217215582314
PubMedGoogle ScholarCrossref 5.Haines DE, Wang Y, Curtis J. Implantable cardioverter-defibrillator registry risk score models for acute procedural complications or death after implantable cardioverter-defibrillator implantation.
Circulation. 2011;123(19):2069-207621537001
PubMedGoogle ScholarCrossref 6.Kleemann T, Becker T, Doenges K,
et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
Circulation. 2007;115(19):2474-248017470696
PubMedGoogle ScholarCrossref 7.Palacios-Ceña D, Losa-Iglesias ME, Alvarez-López C,
et al. Patients, intimate partners and family experiences of implantable cardioverter defibrillators: qualitative systematic review.
J Adv Nurs. 2011;67(12):2537-255021615459
PubMedGoogle ScholarCrossref 8.Dunbar SB. Psychosocial issues of patients with implantable cardioverter defibrillators.
Am J Crit Care. 2005;14(4):294-30315980420
PubMedGoogle Scholar 9.Pedersen SS, den Broek KC, Theuns DA,
et al. Risk of chronic anxiety in implantable defibrillator patients: a multi-center study.
Int J Cardiol. 2011;147(3):420-42319896732
PubMedGoogle ScholarCrossref 10.Swindle JP, Rich MW, McCann P, Burroughs TE, Hauptman PJ. Implantable cardiac device procedures in older patients: use and in-hospital outcomes.
Arch Intern Med. 2010;170(7):631-63720386008
PubMedGoogle ScholarCrossref 11.Epstein AE, Kay GN, Plumb VJ,
et al; ACT Investigators. Implantable cardioverter-defibrillator prescription in the elderly.
Heart Rhythm. 2009;6(8):1136-114319539542
PubMedGoogle ScholarCrossref 12.Matlock DD, Nowels CT, Masoudi FA,
et al. Patient and cardiologist perceptions on decision making for implantable cardioverter-defibrillators: a qualitative study.
Pacing Clin Electrophysiol. 2011;34(12):1634-164421972983
PubMedGoogle ScholarCrossref 13.Stewart GC, Weintraub JR, Pratibhu PP,
et al. Patient expectations from implantable defibrillators to prevent death in heart failure.
J Card Fail. 2010;16(2):106-11320142021
PubMedGoogle ScholarCrossref 14.Morgan DL. Focus Groups as Qualitative Research. 2nd ed. Thousand Oaks, CA: Sage Publications; 1997. Qualitative Research Methods Series 16
15.Johnson B, Christensen L. Educational Research: Quantitative, Qualitative, and Mixed Approaches. 2nd ed. Needham Heights, MA: Allyn & Bacon; 2004
16.Langford BE, Schoenfeld G, Izzo G. Nominal grouping sessions vs focus groups.
Qual Mark Res. 2002;5(1):58-70
Google ScholarCrossref 17.Krueger RA. Focus Groups: A Practical Guide for Applied Research. 4th ed. Thousand Oaks, CA: Sage Publications; 2009
20.Glassman PA, Luck J, O’Gara EM, Peabody JW. Using standardized patients to measure quality: evidence from the literature and a prospective study.
Jt Comm J Qual Improv. 2000;26(11):644-65311098427
PubMedGoogle Scholar 21.Beullens J, Rethans JJ, Goedhuys J, Buntinx F. The use of standardized patients in research in general practice.
Fam Pract. 1997;14(1):58-629061346
PubMedGoogle ScholarCrossref 22.Franz CE, Epstein R, Miller KN,
et al. Caught in the act? prevalence, predictors, and consequences of physician detection of unannounced standardized patients.
Health Serv Res. 2006;41(6):2290-230217116121
PubMedGoogle ScholarCrossref 23.Peabody JW, Luck J, Glassman P, Dresselhaus TR, Lee M. Comparison of vignettes, standardized patients, and chart abstraction: a prospective validation study of 3 methods for measuring quality.
JAMA. 2000;283(13):1715-172210755498
PubMedGoogle ScholarCrossref 24.Kravitz RL, Franks P, Feldman M,
et al. What drives referral from primary care physicians to mental health specialists? a randomized trial using actors portraying depressive symptoms.
J Gen Intern Med. 2006;21(6):584-58916808740
PubMedGoogle ScholarCrossref 26.Jessup M, Abraham WT, Casey DE,
et al. 2009 Focused update: ACCF/AHA guidelines for the diagnosis and management of heart failure in adults: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines: developed in collaboration with the International Society for Heart and Lung Transplantation.
Circulation. 2009;119(14):1977-201612351358
PubMedGoogle ScholarCrossref 27.Tung R, Swerdlow CD. Refining patient selection for primary prevention implantable cardioverter-defibrillator therapy: reeling in a net cast too widely.
Circulation. 2009;120(10):825-82719704090
PubMedGoogle ScholarCrossref 28.Parkash R, Stevenson WG, Epstein LM, Maisel WH. Predicting early mortality after implantable defibrillator implantation: a clinical risk score for optimal patient selection.
Am Heart J. 2006;151(2):397-40316442906
PubMedGoogle ScholarCrossref 29.Goldenberg I, Vyas AK, Hall WJ,
et al; MADIT-II Investigators. Risk stratification for primary implantation of a cardioverter-defibrillator in patients with ischemic left ventricular dysfunction.
J Am Coll Cardiol. 2008;51(3):288-29618206738
PubMedGoogle ScholarCrossref 30.Eckart RE, Gula LJ, Reynolds MR, Shry EA, Maisel WH. Mortality following defibrillator implantation in patients with renal insufficiency.
J Cardiovasc Electrophysiol. 2006;17(9):940-94316948736
PubMedGoogle ScholarCrossref 31.Swindle J, Burroughs TE, Schnitzler MA, Hauptman PJ. Short-term mortality and costs associated with cardiac device implantation in patients hospitalized with heart failure.
Am Heart J. 2008;156(2):322-32812351358
PubMedGoogle ScholarCrossref 32.Setoguchi S, Nohria A, Rassen JA, Stevenson LW, Schneeweiss S. Maximum potential benefit of implantable defibrillators in preventing sudden death after hospital admission because of heart failure.
CMAJ. 2009;180(6):611-61619289804
PubMedGoogle Scholar 33.Maisel WH. Safety issues involving medical devices: implications of recent implantable cardioverter-defibrillator malfunctions.
JAMA. 2005;294(8):955-95816118386
PubMedGoogle ScholarCrossref 34.Daubert JP, Zareba W, Cannom DS,
et al; MADIT II Investigators. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.
J Am Coll Cardiol. 2008;51(14):1357-136518387436
PubMedGoogle ScholarCrossref 35.Namerow PB, Firth BR, Heywood GM, Windle JR, Parides MK. Quality-of-life six months after CABG surgery in patients randomized to ICD versus no ICD therapy: findings from the CABG Patch Trial.
Pacing Clin Electrophysiol. 1999;22(9):1305-131310527011
PubMedGoogle ScholarCrossref 36.Schron EB, Exner DV, Yao Q,
et al. Quality of life in the Antiarrhythmics Versus Implantable Defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks.
Circulation. 2002;105(5):589-59411827924
PubMedGoogle ScholarCrossref 37.Passman R, Subacius H, Ruo B,
et al. Implantable cardioverter defibrillators and quality of life: results from the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation study.
Arch Intern Med. 2007;167(20):2226-223217998496
PubMedGoogle ScholarCrossref 38.Sears SF, Todaro JF, Urizar G,
et al. Assessing the psychosocial impact of the ICD: a national survey of implantable cardioverter defibrillator health care providers.
Pacing Clin Electrophysiol. 2000;23(6):939-94510879376
PubMedGoogle ScholarCrossref 39.Sears SF Jr, Todaro JF, Lewis TS, Sotile W, Conti JB. Examining the psychosocial impact of implantable cardioverter defibrillators: a literature review.
Clin Cardiol. 1999;22(7):481-48910410293
PubMedGoogle ScholarCrossref 40.Goldstein NE, Back AL, Morrison RS. Titrating guidance: a model to guide physicians in assisting patients and family members who are facing complex decisions.
Arch Intern Med. 2008;168(16):1733-173918779459
PubMedGoogle ScholarCrossref 41.Steinke EE, Gill-Hopple K, Valdez D, Wooster M. Sexual concerns and educational needs after an implantable cardioverter defibrillator.
Heart Lung. 2005;34(5):299-30816157184
PubMedGoogle ScholarCrossref 42.Tagney J, James JE, Albarran JW. Exploring the patient's experiences of learning to live with an implantable cardioverter defibrillator (ICD) from one UK centre: a qualitative study.
Eur J Cardiovasc Nurs. 2003;2(3):195-20314622627
PubMedGoogle ScholarCrossref 43.Anderson CC. The postmodern heart: war veterans' experiences of invasive cardiac technology.
J Adv Nurs. 2004;46(3):253-26115066103
PubMedGoogle ScholarCrossref 44.Dickerson SS. Redefining life while forestalling death: living with an implantable cardioverter defibrillator after a sudden cardiac death experience.
Qual Health Res. 2002;12(3):360-37211918101
PubMedGoogle ScholarCrossref 45.Bolse K, Hamilton G, Flanagan J, Caroll DL, Fridlund B. Ways of experiencing the life situation among United States patients with an implantable cardioverter-defibrillator: a qualitative study.
Prog Cardiovasc Nurs. 2005;20(1):4-1015785164
PubMedGoogle ScholarCrossref 46.Flemme I, Bolse K, Ivarsson A,
et al. Life situation of patients with an implantable cardioverter defibrillator: a descriptive longitudinal study.
J Clin Nurs. 2001;10(4):563-57211822504
PubMedGoogle ScholarCrossref 47.Flemme I, Edvardsson N, Hinic H, Jinhage BM, Dalman M, Fridlund B. Long-term quality of life and uncertainty in patients living with an implantable cardioverter defibrillator.
Heart Lung. 2005;34(6):386-39216324957
PubMedGoogle ScholarCrossref 48.Agård A, Löfmark R, Edvardsson N, Ekman I. Views of patients with heart failure about their role in the decision to start implantable cardioverter defibrillator treatment: prescription rather than participation.
J Med Ethics. 2007;33(9):514-51817761818
PubMedGoogle ScholarCrossref 49.Allen LA, Yager JE, Funk MJ,
et al. Discordance between patient-predicted and model-predicted life expectancy among ambulatory patients with heart failure.
JAMA. 2008;299(21):2533-254218523222
PubMedGoogle ScholarCrossref 50.Goldstein NE, Lampert R, Bradley E, Lynn J, Krumholz HM. Management of implantable cardioverter defibrillators in end-of-life care.
Ann Intern Med. 2004;141(11):835-83815583224
PubMedGoogle ScholarCrossref 51.Kirkpatrick JN, Gottlieb M, Sehgal P, Patel R, Verdino RJ. Deactivation of implantable cardioverter defibrillators in terminal illness and end of life care.
Am J Cardiol. 2012;109(1):91-9421943937
PubMedGoogle ScholarCrossref 52.Goldstein NE, Mehta D, Siddiqui S,
et al. “That's like an act of suicide”: patients' attitudes toward deactivation of implantable defibrillators.
J Gen Intern Med. 2008;23:(suppl 1)
7-1218095037
PubMedGoogle ScholarCrossref 53.Prudente LA, Reigle J, Bourguignon C, Haines DE, DiMarco JP. Psychological indices and phantom shocks in patients with ICD.
J Interv Card Electrophysiol. 2006;15(3):185-19017019638
PubMedGoogle ScholarCrossref 54.Gibson DP, Kuntz KK, Levenson JL, Ellenbogen KA. Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillator.
Europace. 2008;10(5):540-54418442964
PubMedGoogle ScholarCrossref 55.Stevenson LW, Desai AS. Selecting patients for discussion of the ICD as primary prevention for sudden death in heart failure.
J Card Fail. 2006;12(6):407-41216911905
PubMedGoogle ScholarCrossref 56.Back AL, Arnold RM, Baile WF,
et al. Faculty development to change the paradigm of communication skills teaching in oncology.
J Clin Oncol. 2009;27(7):1137-114119171703
PubMedGoogle ScholarCrossref