Photobleaching by Spectralis Fixation Target | Medical Devices and Equipment | JAMA Ophthalmology | JAMA Network
[Skip to Navigation]
Access to paid content on this site is currently suspended due to excessive activity being detected from your IP address 18.206.238.77. Please contact the publisher to request reinstatement.
1.
Sparrow  JR, Duncker  T.  Fundus autofluorescence and RPE lipofuscin in age-related macular degeneration.  J Clin Med. 2014;3(4):1302-1321.PubMedGoogle ScholarCrossref
2.
Gabai  A, Veritti  D, Lanzetta  P.  Fundus autofluorescence applications in retinal imaging.  Indian J Ophthalmol. 2015;63(5):406-415.PubMedGoogle ScholarCrossref
3.
von Rückmann  A, Fitzke  FW, Bird  AC.  Distribution of fundus autofluorescence with a scanning laser ophthalmoscope.  Br J Ophthalmol. 1995;79(5):407-412.PubMedGoogle ScholarCrossref
4.
Prieto  PM, McLellan  JS, Burns  SA.  Investigating the light absorption in a single pass through the photoreceptor layer by means of the lipofuscin fluorescence.  Vision Res. 2005;45(15):1957-1965.PubMedGoogle ScholarCrossref
Brief Report
September 2016

Photobleaching by Spectralis Fixation Target

Author Affiliations
  • 1Department of Ophthalmology, University Vita-Salute, Istituto di Ricovero e Cura a Carattere Scientifico San Raffaele, Milan, Italy
JAMA Ophthalmol. 2016;134(9):1060-1062. doi:10.1001/jamaophthalmol.2016.2283
Abstract

Importance  The aim of this study is to determine whether the cross-shaped fixation target in a spectral-domain optical coherence tomography instrument (Spectralis; Heidelberg Engineering) could produce a cross-shaped increase fundus autofluorescence artifact on subsequent imaging.

Observations  Thirty eyes of 15 healthy volunteers (8 women and 7 men; mean [SD] age 24 [3] years) were included in the study, which was conducted between October 2015 and December 2015. In all eyes, a cross-shaped increase in macular autofluorescence with variable intensity occurred after Spectralis spectral-domain optical coherence tomography acquisition. This peculiar pattern was also detected on confocal scanning laser ophthalmoscope infrared reflectance and MultiColor imaging. Interestingly, no changes in macular fundus autofluorescence pattern were evident after optical coherence tomography acquisition with either Cirrus HD-OCT 5000 or RTVue XR Avanti.

Conclusions and Relevance  In an era characterized by extensive use of optical coherence tomography examination in clinical practice, the potential deleterious effects related to photopigments consumption by Spectralis optical coherence tomography fixation point deserve further investigation.

×