[Skip to Content]
Access to paid content on this site is currently suspended due to excessive activity being detected from your IP address 35.175.201.14. Please contact the publisher to request reinstatement.
[Skip to Content Landing]
Clinical Sciences
August 2000

Flicker Sensitivity and Cardiovascular Function in Healthy Middle-aged People

Author Affiliations

From the Neurological Sciences Institute (Dr Eisner) and the Casey Eye Institute (Dr Samples), Oregon Health Sciences University, Portland. The authors do not have any commercial or proprietary interests in the devices used for this research. Likewise, they do not have any financial interests or receive payment as consultants, reviewers, or educators.

Arch Ophthalmol. 2000;118(8):1049-1055. doi:10.1001/archopht.118.8.1049
Abstract

Objective  To establish normative relations between measures of visual function and cardiovascular variables that are important for age-related disease, including various forms of glaucoma.

Methods  Foveal flicker sensitivities, resting blood pressures and heart rates, and intraocular pressures were measured in 18 individuals aged 40 to 68 years. All subjects had 20/20 or better visual acuity in the test eye and no evidence of eye disease or glaucoma suspicion on clinical evaluation and medical history. No subjects were using medication to lower blood pressure. Flicker sensitivity was measured by increasing the illuminance of a fully modulated 20-Hz test stimulus until flicker was perceived. Two test-background stimulus combinations were used: a 570-nm ("yellow") test on a predominantly long-wavelength ("magenta") background and a 580-nm ("yellow") test on a 580-nm ("yellow") background. The illuminance of the yellow background was dimmer than that typically used for short-wavelength automated perimetry, whereas the illuminance of the magenta background was greater.

Results  The 2 flicker sensitivity measures were distinguished by the strong dependence of the magenta background measure on the ratio of mean arterial blood pressure to heart rate. Log flicker sensitivity on this background generally could be modeled as a linear combination of age, intraocular pressure, and ratio of mean arterial blood pressure to heart rate. The optimal model accounted for 84% of the variance (R = 0.92) from all but 2 outlying individuals. After age and intraocular pressure effects were partialed out, an increasing ratio of mean arterial blood pressure to heart rate was strongly associated with decreasing flicker sensitivity.

Conclusions  Reduced cardiovascular function impacts the ability of the normal visual system to adapt and regulate flicker sensitivity. Elevated intraocular pressure and increased age reduce flicker sensitivity relatively uniformly across a range of stimulus conditions. Because the ratio of mean arterial blood pressure to heart rate equals total peripheral vascular resistance multiplied by cardiac stroke volume, and because total peripheral resistance is determined largely at the arterioles, it is likely that even modest changes in arteriolar function are associated with measurable alterations of visual function.

×