Objective
To develop a quantitative measure of regional variation in choroidal blood flow (ChBF).
Methods
Five million 15-μm fluorescent microspheres were injected into the left ventricles of 4 rabbits and 3 monkeys. The fixed globes were bleached, flat mounted, and photomicrographed. After image analysis to locate each microsphere, regional densities and blood flow were determined.
Results
Regional variation in ChBF was clearly evident. In the rabbit, a high density of spheres was seen in the visual streak. This was surrounded by a middle peripheral area of low sphere density and a far peripheral region of moderately high density. In the monkeys, sphere density was markedly greater in the macula compared with the periphery. Contour plots produced lines of constant flow that were oval and extended farther nasally than temporally in the monkeys. The ratio of central to peripheral ChBF was much greater in the monkeys than in the rabbits.
Conclusion
Quantitative assessment of regional ChBF can be performed using a modification of the fluorescent microsphere impaction method.
Clinical Relevance
This method of determining regional ChBF will be useful for studying the vascular effects of pharmacologic agents and for characterizing animal models of human disease involving the outer retina.
Choroidal blood flow (ChBF) accounts for 85% of the circulation to the eye.1-3 Knowing how it is affected by disease and pharmacologic intervention is critically important. However, measurement of ChBF is problematic because its vasculature is partially hidden from view by the overlying retinal pigment epithelium (RPE). Numerous methods have been developed, none of which is completely satisfactory for all experimental purposes. A brief review of some of these methods follows.
Total ChBF can be determined invasively by cutting the vortex veins and measuring output.4 A noninvasive method is color Doppler ultrasonic flowmetry of the ophthalmic artery,5-9 which serves as an estimate of ChBF given that 85% of its flow serves the choroid. Laser interferometry10-12 and laser Doppler flowmetry13 are also noninvasive techniques, but ChBF measurement is limited to the fovea. Radioactive krypton desaturation,14 hydrogen clearance,15 and calorimetric methods16 have also been used. Choroidal blood flow in localized areas has been estimated using fluorescein dye–filling curves17 and indocyanine green dye.18 A recently described novel means of studying ChBF in small portions of the choroid uses laser rupture of dye-laden liposomes.19,20
Except for direct measurement at the vortex veins, all of these methods are limited in that they are approximations of ChBF, show only relative blood flow, or look at selected small regions of the choroid. One additional, highly accurate means of determining blood flow is the use of arterially injected nonrecirculating labeled microspheres. The density of spheres in any given tissue is proportional to the blood flow through that tissue at the time of injection. An absolute blood flow determination can be made by simultaneously withdrawing a reference sample of arterial blood. Multiple injections using differentially labeled spheres is also possible, permitting the technique to be used to determine acute changes in blood flow in response to changes in various physiologic variables, such as blood pressure, oxygenation, and pharmacologic intervention.
The use of radiolabeled microspheres to measure blood flow in nonsurvival experiments was introduced by Rudolph and Heymann in 1967.21 Since then, it has become the accepted standard for determining arterial flow to capillary beds in various organs, including the choroids of the cynomolgus (Macaca fascicularis) monkey1,22,23 and several other species.22,24 More recently, fluorescent microspheres have been used.25-28 In 1993, Austin et al29 and Glenny et al30 described quantitative comparisons of the 2 types of microspheres and found that they give similar results in terms of blood flow. The technique using fluorescent microspheres has since been shown to be at least as reliable as that using radiolabeled microspheres,30-34 and without the health and environmental risks or costs of tissue disposal and storage.
In the present study, we investigated the use of fluorescent microspheres to determine regional differences in blood flow of the choriocapillaris. Buckberg et al35 analyzed the statistical variability of the distribution of microspheres and concluded that at least 384 spheres are needed in a given volume of tissue to have a precision of 10% at the 95% confidence level. Although the choroid is a high-flow system, the total volume of tissue is small compared with other organs, thus limiting the total number of microspheres that reach the choroid. Dividing the choroid into small segments might be problematic in terms of getting enough spheres for adequate statistical analysis. It is possible to compensate for this somewhat by injecting a larger number of spheres systemically. Almegard and Andersson36 administered 2 injections of 4 to 6 × 106 radiolabeled microspheres (15 μm in diameter) each into cynomolgus monkeys weighing 2.2 to 3.6 kg without a marked reduction in blood pressure. Orgul et al injected as many as 100 × 106 colored microspheres (10.2 μm in diameter) into rabbits37 and rhesus monkeys.38 An alternative approach to increasing the precision of the analyses is to use a larger number of animals.35 Finally, if the differences in flow between regions are greater than 10%, a lower density of spheres might suffice.
Although most studies of ChBF using the microsphere impaction method have looked at total blood flow, a few investigators have attempted to identify regional variation in flow. Alm and Bill24 examined 7 areas of the choroid in the cat and found no regional differences in flow. However, these same investigators found significant differences in the monkey (Macaca irus) comparing peripapillary, foveal, intermediary, and peripheral locations.1 In both studies, the choroid was divided into pieces that were analyzed separately. Autoradiographs of flat mounts of whole choroids have been performed in monkeys1 and rabbits.39 Although no attempt was made to quantitate the results, the researchers concluded that the microspheres had greater density in the macula of the monkey and in the visual streak of the rabbit compared with the periphery in both species. Stern and Ernest3 visualized colored microspheres in flat mounts of rhesus monkey choroids. They observed that the concentration of spheres at the region of the fovea was 5 to 6 times greater than the concentration at the temporal equator.
These methods of determining regional ChBF all have their limitations. Physically dividing the choroid into small pieces and counting the spheres in each piece, apart from being time-consuming, introduces errors because of the inaccuracy introduced in trying to cut the pieces into equal sizes. Furthermore, the sampling bin size is fixed, which limits the analyses that are possible. Autoradiography of the entire choroid, while giving a good subjective sense of regional differences in flow, is difficult to quantitate because an overlying film emulsion is used and what is recorded is not the exact location of the individual spheres but the paths of the particles emitted by the radionuclide as they pass through the emulsion at various angles. Depending on the exposure time, variability relating to decay rate is introduced as well. Directly visualizing individual colored or fluorescent spheres is problematic in pigmented animals because the RPE (whose pigment itself is variable across the eye)40 blocks the view of an undetermined portion of the spheres.
In this article, we describe a new method for preparing flat whole mounts of choroids from rabbits and monkeys that have been injected with fluorescent microspheres. Potassium permanganate is used to bleach the RPE, and the cartesian coordinates of each individual sphere are determined in a semi-automated manner. From these data, quantitative analyses are performed and density plots are generated that show contour lines of equal blood flow. Note that the term ChBF in the context of the fluorescent microsphere impaction method means the blood flow in the choriocapillaris because that is where the microspheres are impacted. No microspheres remain in the large choroidal vessels.
Institutional guidelines regarding animal experimentation were followed. Five million fluorescent polystyrene microspheres (mean ± SD diameter, 15.5 ± 0.42 μm) (Molecular Probes, Eugene, Ore) were injected in 25 seconds into the left ventricle via a catheter inserted into the right femoral artery of 4 New Zealand Black rabbits, a rhesus (Macaca mulatta) monkey, and 2 cynomolgus (M fascicularis) monkeys. Each animal's left ventricular and aortic pressure was monitored during the injection procedure using a physiologic recorder (WindoGraf 930; Gould Instrument Systems, Valley View, Ohio). The stock concentration of microspheres was 1 million per milliliter, with excitation and emission peaks of either 505 and 515 nm, respectively (yellow-green fluorescent), or 580 and 650 nm (red fluorescent). The left femoral artery was also catheterized and used for obtaining reference blood samples. For the reference samples, a syringe pump (Harvard Apparatus Inc, Holliston, Mass) was fitted with a 10-mL syringe containing 0.6 mL of heparin sodium (1000 USP U/mL) and was used to aspirate the arterial blood at a rate of 1 mL/min for 2 minutes. The reference sample was withdrawn simultaneously with the fluorescent microsphere injection. Immediately after the fluorescent microsphere injection, a 3-mL volume of heparinized saline (20 U/mL in 0.9% sodium chloride solution) was injected to flush the fluorescent microspheres through the catheter. After aspiration, the syringe and the connecting catheter were rinsed twice with 3 mL of 2% Tween 80. The blood plus the rinse solution were deposited in a 50-mL plastic collection tube that was weighed before and after to determine the weight of the blood plus rinse solution. The arterial blood in the catheter was drawn into the reference sample syringe, and the contents were deposited in a 50-mL conical polypropylene centrifuge tube. The syringe was then rinsed twice as described previously herein.
The animals were humanely killed and their eyes were enucleated, placed in 4% paraformaldehyde overnight at 4°C, and stored in 0.1M phosphate buffer (pH, 7.6) at 4°C. After the anterior segments of the eyes were removed, the retinas were carefully dissected away from the underlying RPE and choroid. A 1.5-mm trephine was then used to free the retina at the optic nerve. The anterior cut edge of the RPE/choroid was then tacked to the underlying sclera with cyanoacrylate glue. This last step was done to help prevent shifting of the RPE/choroid when it was being flattened (see later in this article). The posterior poles were incubated in 0.25% potassium permanganate at 37°C for 30 to 60 minutes. They were then placed in 5% oxalic acid for 5 minutes, flattened with 8 radial cuts, laid out on a layer of nonhardening modeling clay (sclera against the clay), covered with 2.5% hydroxypropylmethylcellulose, and pressed between 2 glass slides. Contact tape was wrapped around the 2 ends of the slides to hold them together.
The total number of microspheres in the samples was calculated by manually counting the spheres in 40-μL aliquot samples from the well-agitated (by means of sonication and vortexing) collection tube. The aliquots were placed on large microscope slides and coverslipped. An epifluorescence microscope (Olympus BH2; Olympus America Inc, Melville, NY) was used to visualize the spheres. A sufficient number of aliquots were used so that at least 400 microspheres were counted per sample. Assuming that the liquid in the collection tube was 1 mL/g, the total number of microspheres in the reference sample (Sr) was calculated as
Sr = Sa(Vt/Va),
where Sa is the total number of microspheres in the aliquots, Vt is the volume of liquid in the collection tube, and Va is the total volume of all of the aliquots used for counting.
The microspheres in the flattened and bleached globes were photographed using a digital camera attached to an epifluorescence microscope. Approximately 50 micrographs were needed to image the entire specimen using a ×2 objective lens. A single high-resolution image composed of the 50 micrographs was produced using Adobe Photoshop 7.0 (Adobe Systems Inc, San Jose, Calif). The cartesian coordinates of each microsphere were then determined using NIH ImageJ v1.31 (National Institutes of Health, Bethesda, Md). Approximately half of the total number of spheres could be detected automatically using ImageJ, and the remaining half had to be identified manually (because they were touching other spheres) using the ImageJ crosshair tool. The data were processed using a customized program in MATLAB v6.5.1 (The MathWorks, Natick, Mass), written by one of us (J.N.V.H.), which tabulates and plots the number of microspheres in bins of any size (0.25-mm2 bins worked well for this study). Blood flow was calculated using the following formula:
ChBF = R(Scc/Sr),
where R is the rate at which blood was withdrawn for the reference sample, in microliters per minute; Scc is the number of spheres per square millimeter of tissue; and Sr is the total number of spheres in the reference sample. These values were then imported into SigmaPlot 2001 (SPSS Inc, Chicago, Ill) along with the cartesian coordinates of the bins. A 3-dimensional smoothing function was used (locally weighted scatterplot smooth [loess (from the SigmaPlot 2001 program)], fourth-order polynomial) to produce a contour plot of blood flow in microliters per minute per square millimeter.
In the literature, ChBF is often expressed in milligrams per minute, which is a shorthand notation for milligrams per minute per tissue. In other words, the total blood flow through the choroid would be measured in milligrams per minute per choroid. In this article, we assume that the specific gravity of blood is approximately 1.0 and thus substitute microliters for milligrams. Also, we are interested in regional variations in blood flow in what is essentially a 2-dimensional capillary bed (the choriocapillaris). Dividing by area, the units then become microliters per minute per square millimeter. Flow measured in this way is sometimes referred to as flux density, or volume of a fluid per time through a given area.
The Table gives the total ChBF of each eye tested. Although variable among animals, these flows were similar to those reported by other researchers in rabbits39,41-45 and monkeys1,22,42,46 using nonrecirculating microspheres (see the “Comment” section).
Figure 1 illustrates the appearance of the posterior pole of a rabbit eye (rabbit 4) after it had been bleached and flattened between 2 glass slides. The retina had been removed before bleaching. Some choroidal pigmentation remained after bleaching, especially in the peripapillary and far peripheral regions. However, the RPE was fully bleached everywhere so that it did not interfere with visualization of the fluorescent microspheres (Figure 2).
Once photographed using an epifluorescence microscope, the cartesian coordinates of each individual sphere were determined in a semi-automated manner (see the “Methods” section) and plotted (Figure 3). By simple inspection of these plots, it was evident that there was a much greater density of microspheres in the portion of the eye corresponding to the visual streak in all of the rabbit eyes. Further quantitative analysis involved sorting the data into either 0.25- or 1-mm2 bins (Figure 4). Blood flow corresponding to each bin was calculated according to the equation ChBF = R(Scc/Sr) (see the “Methods” section). These data were then smoothed and replotted as described previously. No attempt was made to compensate for the missing areas produced by the radial cuts, which gave the smoothed graphs a lumpy appearance in the periphery (Figure 5 and Figure 6). From the smoothed plots, it was apparent that in addition to the higher blood flow in the visual streak, there were 2 areas of greatly lower blood flow corresponding to the choroid just dorsal to and just ventral to the visual streak. Blood flow was also found to be greater toward the far periphery everywhere except directly dorsal to the optic nerve.
Contour plots using lines of equal ChBF showed that the high- and low-flow areas differed by a factor of approximately 3. The features of these plots were relatively insensitive to the size of the bins chosen (Figure 7). The monkeys (rhesus and cynomolgus) showed a much different pattern of blood flow than was the case for the rabbits. In these animals, there was a marked concentration of microspheres in the central macula and a much reduced density in the periphery (cynomolgus 2) (Figure 8). This was especially evident in the smoothed plots (Figure 9). Examination of the contour plots revealed that the lines representing equal ChBF were not simply concentric circles but rather fell off more slowly in the nasal retina (corresponding to the temporal visual field) than they did in the temporal retina (nasal visual field) (Figure 10). In contrast to the rabbit, the high- and low-flow regions differed by a factor of as much as 13.
Regional variations in ChBF can be identified and analyzed quantitatively using this new method of detecting the distribution of nonrecirculating fluorescent microspheres. As noted early in this article, it is theoretically possible to accomplish such an analysis by dividing the choroid into numerous small pieces and determining the number of microspheres in each piece (using a scintillation counter for radiolabeled microspheres or a spectrofluorophotometer/particle sorter for fluorescent microspheres). However, this has yet to be done for more than 7 pieces, presumably because it would be difficult to cut the tissue into equal-sized pieces on the order of 0.25 or 1 mm2. Also, such a method would be unwieldy. For example, the MATLAB analysis performed for rabbit 4 mathematically divided the choroid into 1950 bins (Figure 4). Having to physically process each piece separately, even with some sort of automation, would be untenable. Furthermore, reanalysis, such as that shown in Figure 7 using different bin sizes, is not possible once the tissue is physically sectioned.
Dividing the choroid into so many bins results in fewer than the traditional 400 microspheres per sample.35 Nevertheless, use of the loess curve-smoothing function compensates for this because each smoothed value is determined by neighboring bins within a defined span. In other words, several bins are combined in a weighted manner to produce each point on the curve. Of course, 400 microspheres per sample is not an absolute limit. It is only the level at which the statistical variability from random distribution is approximately 10%. Lower numbers are acceptable if the differences to be detected are greater than 10%,35 which is the case with ChBF because the regional variations are approximately several hundred percent. Finally, even if 400 were used as a strict limit, it would still be possible to divide a choroid such as that shown in Figure 2 into 55 segments (albeit of different sizes), each with 400 spheres.
The 15-μm microspheres used in this study represent a fairly standard size for investigating ChBF. There is probably a range of sizes that could be used that would give a similar result in terms of the calculated blood flow. The choice has to do with finding the optimal combination of size and total number of spheres injected for any given capillary bed. Large spheres are almost all entrapped but block the larger precapillary arterioles, which causes systemic effects if injected in large numbers. Because they block larger vessels, the initial microspheres to reach a capillary bed block subsequent spheres, thus giving an artifactitiously low value for blood flow. Small spheres have the advantage that they can be injected in larger numbers (increasing precision), presumably because they do not affect certain capillary beds needed for maintaining cardiovascular stability. If they are too small, the spheres will escape entrapment from the capillary bed of interest, thus giving a value that is below the actual blood flow. Buckberg et al35 found little difference in calculated blood flow when they compared microspheres in the 8- to 50-μm range. Specifically addressing the issue of sphere size and calculated blood flow in the eye, Alm et al22 performed simultaneous injections of 2 different-sized microspheres (each size with distinctive radiolabels). They found that for the choroid in rabbits, the mean ± SD ratio of 15-μm microspheres to 9-μm microspheres was 1.06 ± 0.02. Similarly, the mean ± SD ratio of 35-μm microspheres to 15-μm microspheres in cynomolgus monkey choroid was 1.02 ± 0.07. In other words, the diameter of the microspheres in the studied range made little difference with respect to calculated ChBF, but size was important for other capillary beds in the eye. The 15:9-μm ratios were more than 2 for the iris and ciliary body in rabbits. The 35:15-μm ratio was less than 1 for the retina and iris in the monkey. They concluded that for the choroid at least, 15 μm provided a reasonable balance between precision and accuracy. The choroid is a high-flow system. In the present study, we injected enough of the 15-μm microspheres to achieve a good statistical sampling but not so many as to affect the cardiovascular stability of the animals.
Total blood flow through the choroid varied considerably among animals (Table). However, such variability has been well described. Alm and Bill,24 using the microsphere method for whole choroids, noted that blood flows differed by as much as a factor of 3.5 among cats with similar perfusion pressures. (As in the present study, they carefully monitored the animals' physiologic variables.) Similarly, Stjernschantz et al41 found ChBF that differed by a factor of 4 in rabbits (excluding an outlier animal that would raise the factor to nearly 7). Despite such marked differences in flow among animals, measurement of ChBF has proved useful in part because the fluctuation in flow between eyes and between multiple injections in the same eye is considerably less dramatic (eg, see cynomolgus 1, right and left eyes, in Table).
Although increased ChBF in the visual streak of rabbits and in the macula of monkeys has been observed (at least subjectively) by other researchers, this new method has revealed at least 2 previously undescribed features of ChBF. In the rabbit, there is a region of low flow just ventral to the visual streak centrally and also dorsal to the visual streak above the optic nerve. However, in the other areas of the periphery, including along the axis of the visual steak itself, there is a relative increase in flow. The highest flows are at the nasal and temporal periphery, not at the center of the visual streak. Just why this is so is not obvious. One might speculate that because the rabbit is a prey animal, peripheral vision is more important than central vision. Of course, high ChBF may or may not correlate with good vision. The concentrations of short-wavelength–sensitive cones (S-cones or blue cones) are greatest in the inferior periphery of the rabbit eye.47,48
The other previously undescribed feature of regional ChBF is in the monkey. The contour lines of equal ChBF reach a peak in the central macula, as has previously been shown either subjectively by microsphere impaction or by limited sampling. However, these lines are not radially symmetrical. Instead, they have an increasingly oval shape toward the periphery, extending more nasally than temporally, which would correspond to the temporal and nasal visual fields, respectively. Unlike in rabbits, the peripheral visual acuity in monkeys is known from behavioral testing and is remarkably similar to that seen in humans,49 at least in the central 30°. In humans, the nasal peripheral lines of equal light sensitivity (isopters) of standard Goldmann perimetry extend farther for the nasal field than for the temporal field. Morphologically, similar radial asymmetry of the cone photoreceptors has been found in monkey50,51 and human51,52 retinas. Another interesting feature of the ChBF in monkeys is the much greater range (by a factor of as much as 13) between the central macula and the periphery compared with the rabbit (by a factor of 3) even though total circulation may be similar (see previously in this article).
A priori, it is not necessarily the case that regional variations in ChBF should reflect visual sensitivity as measured in photopic conditions. Mammalian retinas are duplex, containing rods and cones that each have different physiologic characteristics and functions. Furthermore, these characteristics change with light adaptation, the rods being more metabolically active in dark adaptation.53,54 Therefore, is ChBF a reflection more of the cone retina or of the rod retina? One might guess that the ChBF variation should follow the variations in oxygen consumption of the outer retina. Although extensive regional studies of comparative outer retinal oxygen consumption have not been performed, Yu and Cringle55 did a 2-point comparison using oxygen-sensitive electrodes in rabbits. They found that the oxygen demands of the outer retina were greater in the visual streak than in the vascularized portion of the retina just dorsal to the visual streak (where we found a nadir in ChBF). However, this simple relationship may not hold in the monkey. Ahmed et al56 did a similar 2-point analysis in a pig-tailed macaque (Macaca nemestrina) in which they looked at outer retinal oxygen consumption in the fovea compared with the parafoveal region (about halfway between the fovea and the optic disc). They found that oxygen consumption was actually lower in the fovea. The reason for this is not clear, but if the same holds true for cynomolgus and rhesus monkeys, it would suggest that ChBF does not rigidly follow oxygen demand. Such a parafoveal zone of borderline ChBF might account for some of the bull’s-eye maculopathies seen in humans. Without further studies, such comments are speculative. Other factors, such as temperature regulation and (as yet unmeasured) metabolic needs supplied by the choroid, could be important in addition to oxygen supply.
In summary, using the modified fluorescent microsphere impaction method described in this article, we quantitatively examined the entire choroid in rabbits and monkeys and showed a consistent pattern of regional variations in ChBF among the animals studied. Using this method, it may be possible to study regional variations in ChBF in response to the light-dark cycle. The effects of drugs and animal models of retinal disease on regional ChBF may, for the first time, be measurable as well.
Correspondence: T. Michael Nork, MD, Department of Ophthalmology and Visual Sciences, University of Wisconsin Medical School, 600 Highland Ave, F4/336, Madison, WI 53792-3220 (tmnork@wisc.edu).
Submitted for Publication: May 15, 2005; final revision received September 7, 2005; accepted October 23, 2005.
Financial Disclosure: None.
Funding/Support: This study was supported by grants R01 EY014041 (Dr Nork) and P30 EY016665 from the National Eye Institute, National Institutes of Health; the Walter H. Helmerich Chair (Dr Nork); Research to Prevent Blindness; the Retina Research Foundation; and the Wisconsin Lions.
Acknowledgment: We thank Carrie Bunger and Derrick Woodward for providing technical assistance.
1.Alm
ABill
A Ocular and optic nerve blood flow at normal and increased intraocular pressures in monkeys (
Macaca irus): a study with radioactively labelled microspheres including flow determinations in brain and some other tissues.
Exp Eye Res 1973;1515- 29
PubMedGoogle ScholarCrossref 3.Stern
WHErnest
JT Microsphere occlusion of the choriocapillaris in rhesus monkeys.
Am J Ophthalmol 1974;78438- 448
PubMedGoogle Scholar 4.Alm
ABill
A Blood flow and oxygen extraction in the cat uvea at normal and high intraocular pressures.
Acta Physiol Scand 1970;8019- 28
PubMedGoogle ScholarCrossref 5.Rojanapongpun
PDrance
SMMorrison
BJ Ophthalmic artery flow velocity in glaucomatous and normal subjects.
Br J Ophthalmol 1993;7725- 29
PubMedGoogle ScholarCrossref 6.Galassi
FNuzzaci
GSodi
ACasi
PVielmo
A Color Doppler imaging in evaluation of optic nerve blood supply in normal and glaucomatous subjects.
Int Ophthalmol 1992;16273- 276
PubMedGoogle ScholarCrossref 7.Harris
ASergott
RCSpaeth
GLKatz
JLShoemaker
JAMartin
BJ Color Doppler analysis of ocular vessel blood velocity in normal-tension glaucoma.
Am J Ophthalmol 1994;118642- 649
PubMedGoogle Scholar 8.Butt
ZO'Brien
CMcKillop
GAspinall
PAllan
P Color Doppler imaging in untreated high- and normal-pressure open-angle glaucoma.
Invest Ophthalmol Vis Sci 1997;38690- 696
PubMedGoogle Scholar 9.Kaiser
HJSchoetzau
AStumpfig
DFlammer
J Blood-flow velocities of the extraocular vessels in patients with high-tension and normal-tension primary open-angle glaucoma.
Am J Ophthalmol 1997;123320- 327
PubMedGoogle Scholar 10.Schmetterer
LFLexer
FUnfried
CJSattmann
HFercher
AF Topical measurement of fundus pulsations.
Opt Eng 1995;34711- 716
Google ScholarCrossref 11.Schmetterer
LDallinger
SFindl
OEichler
HGWolzt
M A comparison between laser interferometric measurement of fundus pulsation and pneumotonometric measurement of pulsatile ocular blood flow, 1: baseline considerations.
Eye 2000;1439- 45
PubMedGoogle ScholarCrossref 12.Fuchsjager-Mayrl
GWally
BGeorgopoulos
M
et al. Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension.
Invest Ophthalmol Vis Sci 2004;45834- 839
PubMedGoogle ScholarCrossref 13.Riva
CECranstoun
SDGrunwald
JEPetrig
BL Choroidal blood flow in the foveal region of the human ocular fundus.
Invest Ophthalmol Vis Sci 1994;354273- 4281
PubMedGoogle Scholar 14.Friedman
EKopald
HHSmith
TR Retinal and choroidal blood flow determined with krypton-85 anesthetized animals.
Invest Ophthalmol 1964;3539- 547
PubMedGoogle Scholar 15.Yu
DYAlder
VACringle
SJBrown
MJ Choroidal blood flow measured in the dog eye in vivo and in vitro by local hydrogen clearance polarography: validation of a technique and response to raised intraocular pressure.
Exp Eye Res 1988;46289- 303
PubMedGoogle ScholarCrossref 16.Armaly
MFAraki
M Effect of ocular pressure on choroidal circulation in the cat and rhesus monkey.
Invest Ophthalmol 1975;14584- 591
PubMedGoogle Scholar 17.van Stokkum
IHLambrou
GNvan den Berg
TJ Hemodynamic parameter estimation from ocular fluorescein angiograms.
Graefes Arch Clin Exp Ophthalmol 1995;233123- 130
PubMedGoogle ScholarCrossref 18.Flower
RW Extraction of choriocapillaris hemodynamic data from ICG fluorescence angiograms.
Invest Ophthalmol Vis Sci 1993;342720- 2729
PubMedGoogle Scholar 19.Kiryu
JShahidi
MMori
MTOgura
YAsrani
SZeimer
R Noninvasive visualization of the choriocapillaris and its dynamic filling.
Invest Ophthalmol Vis Sci 1994;353724- 3731
PubMedGoogle Scholar 20.Asrani
SZou
SD'Anna
SGoldberg
MFZeimer
R Noninvasive visualization of blood flow in the choriocapillaris of the rat.
Invest Ophthalmol Vis Sci 1996;37312- 317
PubMedGoogle Scholar 21.Rudolph
AMHeymann
MA The circulation of the fetus in utero: methods for studying distribution of blood flow, cardiac output and organ blood flow.
Circ Res 1967;21163- 184
PubMedGoogle ScholarCrossref 22.Alm
ATornquist
PStjernschantz
J Radioactively labelled microspheres in regional ocular blood flow determinations.
Bibl Anat 1977;1624- 29
PubMedGoogle Scholar 23.Alm
ALambrou
GNMaepea
ONilsson
SFPercicot
C Ocular blood flow in experimental glaucoma: a study in cynomolgus monkeys.
Ophthalmologica 1997;211178- 182
PubMedGoogle ScholarCrossref 24.Alm
ABill
A The oxygen supply to the retina, II: effects of high intraocular pressure and of increased arterial carbon dioxide tension on uveal and retinal blood flow in cats: a study with radioactively labelled microspheres including flow determinations in brain and some other tissues.
Acta Physiol Scand 1972;84306- 319
PubMedGoogle ScholarCrossref 25.Gottlieb
GJKubo
SHAlonso
DR Ultrastructural characterization of the border zone surrounding early experimental myocardial infarcts in dogs.
Am J Pathol 1981;103292- 303
PubMedGoogle Scholar 26.Hale
SLVivaldi
MTKloner
RA Fluorescent microspheres: a new tool for visualization of ischemic myocardium in rats.
Am J Physiol 1986;251H863- H868
PubMedGoogle Scholar 27.Kinoshita
KHearse
DJBraimbridge
MVManning
AS “Early” ischemia and reperfusion-induced arrhythmias: antiarrhythmic effects of diltiazem in the conscious rat.
Can J Cardiol 1988;437- 43
PubMedGoogle Scholar 28.Jasper
MSMcDermott
PGann
DSEngeland
WC Measurement of blood flow to the adrenal capsule, cortex and medulla in dogs after hemorrhage by fluorescent microspheres.
J Auton Nerv Syst 1990;30159- 167
PubMedGoogle ScholarCrossref 29.Austin
GETuvlin
MBMartino-Salzman
D
et al. Determination of regional myocardial blood flow using fluorescent microspheres.
Am J Cardiovasc Pathol 1993;4352- 357
PubMedGoogle Scholar 30.Glenny
RWBernard
SBrinkley
M Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
J Appl Physiol 1993;742585- 2597
PubMedGoogle Scholar 31.Abel
FLCooper
RHBeck
RR Use of fluorescent latex microspheres to measure coronary blood flow distribution.
Circ Shock 1993;41156- 161
PubMedGoogle Scholar 32.van Oosterhout
MFPrinzen
FWArts
T
et al. Asynchronous electrical activation induces asymmetrical hypertrophy of the left ventricular wall.
Circulation 1998;98588- 595
PubMedGoogle ScholarCrossref 33.Deveci
DEgginton
S Development of the fluorescent microsphere technique for quantifying regional blood flow in small mammals.
Exp Physiol 1999;84615- 630
PubMedGoogle ScholarCrossref 34.Gervais
MDemolis
PDomergue
VLesage
MRicher
CGiudicelli
JF Systemic and regional hemodynamics assessment in rats with fluorescent microspheres.
J Cardiovasc Pharmacol 1999;33425- 432
PubMedGoogle ScholarCrossref 35.Buckberg
GDLuck
JCPayne
DBHoffman
JIArchie
JPFixler
DE Some sources of error in measuring regional blood flow with radioactive microspheres.
J Appl Physiol 1971;31598- 604
PubMedGoogle Scholar 36.Almegard
BAndersson
SE Vascular effects of calcitonin gene-related peptide (CGRP) and cholecystokinin (CCK) in the monkey eye.
J Ocul Pharmacol 1993;977- 84
PubMedGoogle ScholarCrossref 37.Orgul
SCioffi
GAWilson
DJBacon
DRVan Buskirk
EM An endothelin-1 induced model of optic nerve ischemia in the rabbit.
Invest Ophthalmol Vis Sci 1996;371860- 1869
PubMedGoogle Scholar 38.Orgul
SCioffi
GABacon
DRVan Buskirk
EM An endothelin-1-induced model of chronic optic nerve ischemia in rhesus monkeys.
J Glaucoma 1996;5135- 138
PubMedGoogle Scholar 39.Bill
A Effects of acetazolamide and carotid occlusion on the ocular blood flow in unanesthetized rabbits.
Invest Ophthalmol 1974;13954- 958
PubMedGoogle Scholar 40.Boyer
MMPoulsen
GLNork
TM Relative contributions of the neurosensory retina and retinal pigment epithelium to macular hypofluorescence.
Arch Ophthalmol 2000;11827- 31
PubMedGoogle ScholarCrossref 41.Stjernschantz
JAlm
ABill
A Effects of intracranial oculomotor nerve stimulation on ocular blood flow in rabbits: modification by indomethacin.
Exp Eye Res 1976;23461- 469
PubMedGoogle ScholarCrossref 42.Stjernschantz
JBill
A Effect of intracranial stimulation of the oculomotor nerve on ocular blood flow in the monkey, cat, and rabbit.
Invest Ophthalmol Vis Sci 1979;1899- 103
PubMedGoogle Scholar 43.Bill
A Effects of indomethacin on regional blood flow in conscious rabbits: a microsphere study.
Acta Physiol Scand 1979;105437- 442
PubMedGoogle ScholarCrossref 44.Granstam
ENilsson
SF Non-adrenergic sympathetic vasoconstriction in the eye and some other facial tissues in the rabbit.
Eur J Pharmacol 1990;175175- 186
PubMedGoogle ScholarCrossref 45.Duijm
HFRulo
AHAstin
MMaepea
Ovan den Berg
TJGreve
EL Study of choroidal blood flow by comparison of SLO fluorescein angiography and microspheres.
Exp Eye Res 1996;63693- 704
PubMedGoogle ScholarCrossref 46.Alm
A The effect of topical l-epinephrine on regional ocular blood flow in monkeys.
Invest Ophthalmol Vis Sci 1980;19487- 491
PubMedGoogle Scholar 47.Juliusson
BBergstrom
ARohlich
PEhinger
Bvan Veen
TSzel
A Complementary cone fields of the rabbit retina.
Invest Ophthalmol Vis Sci 1994;35811- 818
PubMedGoogle Scholar 48.Famiglietti
EVSharpe
SJ Regional topography of rod and immunocytochemically characterized “blue” and “green” cone photoreceptors in rabbit retina.
Vis Neurosci 1995;121151- 1175
PubMedGoogle ScholarCrossref 49.Harwerth
RSSmith
EL
IIIDeSantis
L Behavioral perimetry in monkeys.
Invest Ophthalmol Vis Sci 1993;3431- 40
PubMedGoogle Scholar 50.Perry
VHCowey
A The ganglion cell and cone distributions in the monkey's retina: implications for central magnification factors.
Vision Res 1985;251795- 1810
PubMedGoogle ScholarCrossref 51.Curcio
CASloan
KR
JrPacker
OHendrickson
AEKalina
RE Distribution of cones in human and monkey retina: individual variability and radial asymmetry.
Science 1987;236579- 582
PubMedGoogle ScholarCrossref 53.Stefansson
EWolbarsht
MLLanders
MB
III In vivo O
2 consumption in rhesus monkeys in light and dark.
Exp Eye Res 1983;37251- 256
PubMedGoogle ScholarCrossref 54.Linsenmeier
RA Effects of light and darkness on oxygen distribution and consumption in the cat retina.
J Gen Physiol 1986;88521- 542
PubMedGoogle ScholarCrossref 55.Yu
DYCringle
SJ Low oxygen consumption in the inner retina of the visual streak of the rabbit.
Am J Physiol Heart Circ Physiol 2004;286H419- H423
PubMedGoogle ScholarCrossref 56.Ahmed
JBraun
RDDunn
R
JrLinsenmeier
RA Oxygen distribution in the macaque retina.
Invest Ophthalmol Vis Sci 1993;34516- 521
PubMedGoogle Scholar