Figure 1.  Surgical Setup With Clear Plastic Drape (C-Armor) in Place
Surgical Setup With Clear Plastic Drape (C-Armor) in Place
Figure 2.  Spray on Drape After 5 Minutes of Drilling
Spray on Drape After 5 Minutes of Drilling
1.
China News Weekly. Restore the infection path of “Super Communicator” Wuhan Doctor: the epidemic just started. Article in Chinese (simplified). Accessed April 20, 2020. http://View.inews.qq.com/a/20200125A07TT200?uid=&devid=BDFE70CD-5BF1-4702-91B7-329F20A6E839&qimei=bdfe70cd-5bf1-4702-91b7-329f20a6e839
2.
Patel  ZM, Fernandez-Miranda  J, Hwang  PH,  et al.  Letter: precautions for endoscopic transnasal skull base surgery during the COVID-19 pandemic  [published online April 15, 2020].  Neurosurgery. doi:10.1093/neuros/nyaa125PubMedGoogle Scholar
3.
Vukkadala  N, Qian  ZJ, Holsinger  FC, Patel  ZM, Rosenthal  E.  COVID-19 and the otolaryngologist—preliminary evidence-based review  [published online March 26, 2020].  Laryngoscope. doi:10.1002/lary.28672PubMedGoogle Scholar
Views 7,669
Citations 0
Research Letter
April 28, 2020

A Simple Technique for Droplet Control During Mastoid Surgery

Author Affiliations
  • 1Department of Otolaryngology and Communicative Sciences, University of Mississippi Medical Center, Jackson, Mississippi
JAMA Otolaryngol Head Neck Surg. 2020;146(7):671-672. doi:10.1001/jamaoto.2020.1064

For more than 100 years, mastoidectomy has been a common procedure in otolaryngology in the management of cholesteatoma and infections and cochlear implantation. Concerns about droplets and virus aerosolization have been raised during the coronavirus disease 2019 (COVID-19) crisis, particularly after an endoscopic hypophysectomy in Wuhan, China, supposedly led to 14 members of the surgical team becoming infected with the novel coronavirus.1-3 The goal of this case-control study was to devise a drape system to control the droplet spray during mastoidectomy.

Methods

The procedure was carried out on a cadaveric temporal bone in an operating room with a surgeon and a surgical technician. The Zeiss Extaro 300 microscope (Carl Zeiss Meditec AG) was covered with a Zeiss-brand microscope drape. Two different clear drapes were then attached to the lens cap apparatus: the Steri-Drape 1015 (3M) and the C-Armor (Tidi). The Steri-Drape 1015 was attached to the microscope drape using the adhesive along the split and then zipped to itself, with the surgeon putting her arms under the drape. The much larger C-Armor drape was attached by making a 4- to 5-cm incision in the drape and then stretching it tightly around the lens cap cover apparatus of the microscope drape. Because of the large size of the drape, both forearms were inserted through 2 small cuts in the drape to keep a tight fit. Both drapes were then stretched over a Mayo stand at the patient’s head. The clear drape was attached to the surgical drape over the patient chest area using Ioban (3M) to limit aerosol spread toward the anesthetist. Mastoidectomy was then performed in the usual fashion under both drapes, with added methylene blue after the preferred drape was determined to look for gross droplet soiling as well as in a suction scavenger placed near the mastoid. The study was exempt from institutional review board review because it involved single use of deidentified cadaveric tissue.

Results

Surgical visualization was unimpeded with both drapes, and the collection of bone dust and droplets did not cause undue sagging of the drapes. While the split-drape adhesive design of the 1015 drape was easier to attach to the microscope, the C-Armor’s larger size gave much better coverage and overlap with the surgical drape (Figure 1). Furthermore, visualization of the instruments for the technician was easier with the C-Armor rather than the matte finish of the Steri-Drape 1015. Although the surgical procedure was accomplished without the drape getting in the way, extensive irrigation and large bone dust and irrigation droplets were collected on the drape and inside the scavenger suction within minutes (Figure 2).

Discussion

The middle ear cleft is directly connected to the nasopharynx via the eustachian tube and therefore could be considered a possible route of spread for coronavirus or other infections. Furthermore, drilling of the mastoid creates a large cloud of irrigation and bone dust that can easily come in contact with facial skin or be inhaled. While the technique described here is far from airtight, it controls large droplet spray very well using readily available surgical drapes. Other large, clear drapes will probably adapt even better than the 2 tried in this study.

Mastoidectomy is usually an elective procedure and is typically deferred until severe infection is controlled. While rapid COVID-19 screening should ultimately diminish the risk of infecting surgical staff, false negatives will occur, especially in asymptomatic early infections. The risk to the surgeon and staff should be evaluated according to risk stratification protocols, and proper N95 masks and personal protective equipment should be used when indicated. However, it has been our observation that using a microscope with a face shield is virtually impossible, and the method described herein avoids the need for face shields to allow for otherwise normal drilling conditions.

Back to top
Article Information

Accepted for Publication: April 13, 2020.

Corresponding Author: Jeffrey D. Carron, MD, Department of Otolaryngology and Communicative Sciences, University of Mississippi Medical Center, 2500 N State St, Jackson, MS 39216 (jcarron@umc.edu).

Published Online: April 28, 2020. doi:10.1001/jamaoto.2020.1064

Author Contributions: Dr Carron had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

Study concept and design: Eby.

Acquisition, analysis, or interpretation of data: All authors.

Drafting of the manuscript: Carron.

Critical revision of the manuscript for important intellectual content: Buck, Harbarger, Eby.

Administrative, technical, or material support: All authors.

Study supervision: Carron.

Conflict of Interest Disclosures: Dr Carron reported receiving grants from Med-El Corporation outside the submitted work. No other disclosures were reported.

References
1.
China News Weekly. Restore the infection path of “Super Communicator” Wuhan Doctor: the epidemic just started. Article in Chinese (simplified). Accessed April 20, 2020. http://View.inews.qq.com/a/20200125A07TT200?uid=&devid=BDFE70CD-5BF1-4702-91B7-329F20A6E839&qimei=bdfe70cd-5bf1-4702-91b7-329f20a6e839
2.
Patel  ZM, Fernandez-Miranda  J, Hwang  PH,  et al.  Letter: precautions for endoscopic transnasal skull base surgery during the COVID-19 pandemic  [published online April 15, 2020].  Neurosurgery. doi:10.1093/neuros/nyaa125PubMedGoogle Scholar
3.
Vukkadala  N, Qian  ZJ, Holsinger  FC, Patel  ZM, Rosenthal  E.  COVID-19 and the otolaryngologist—preliminary evidence-based review  [published online March 26, 2020].  Laryngoscope. doi:10.1002/lary.28672PubMedGoogle Scholar
×