Objective
Physicians providing emergency department care to children primarily use nebulizers for the delivery of bronchodilators and these physicians have misconceptions regarding the advantages and disadvantages of using metered-dose inhalers (MDIs) with a spacer (MDI + S) for acute asthma exacerbations.
Design
Self-administered mail survey.
Setting
Emergency department.
Participants
Emergency medicine section members of the American Academy of Pediatrics and Canadian Pediatric Society.
Interventions
Bronchodilator delivery methods in acute pediatric asthma.
Main Outcome Measures
The 2 principal outcomes for bivariate analysis were self-reported nebulizer use in all patients and MDI + S use in patients with mild acute asthma.
Results
Of eligible physicians, 333 (51%) of 567 responded. The majority were dual trained in pediatrics and pediatric emergency medicine (72%) and practiced full time (83%) in an urban (83%) pediatric emergency department (80%). The most commonly cited advantages of MDIs were their cost (33%) and speed of use (28%). The most commonly cited disadvantages were patient or parent dissatisfaction (24%) and relative ease of nebulizer use (23%). Only 10% to 21% of participants used MDIs in the emergency department and reserved this delivery method for children with mild asthma exacerbations. There were no significant associations between selected respondent demographic variables and the use of MDIs.
Conclusions
Misconceptions regarding the efficacy and safety of MDI + S for the treatment of acute asthma exacerbations exist but are limited to a minority of surveyed emergency medicine physicians caring for children. Nebulizers remain the preferred method of routine bronchodilator delivery by physicians providing care to pediatric asthmatics in the emergency department.
ASTHMA IS the most common chronic disease of childhood, affecting an estimated 4.8 million children in the United States. Its increasing severity throughout the last 3 decades has been well documented by an increase in hospitalizations from 386 000 to 466 000 (1980 to 1994) and deaths from 1.5 to 6.5 per million (1976 to 1995).1
One area of recent controversy in asthma therapy is the underuse of metered-dose inhalers (MDIs) in adult and pediatric patients.1-4 It is well documented that MDIs with an attached spacer device (MDI + S) require less equipment and time to administer, are cheaper, and are more portable than nebulizers. Furthermore, numerous studies in children and adults have demonstrated that MDI + S are clinically as effective as nebulizers in the delivery of bronchodilators. Clinical equivalence has been proven in many randomized clinical trials using multiple types of spacer devices and bronchodilator medications in children and adults.5-14
The nebulizer system of aerosolized medication delivery is generally accepted as the standard of care for children with acute asthma presenting to the emergency department (ED). This occurs despite the equivalent clinical efficacy and added cost and inconvenience of a nebulizer. The hypotheses of this study were that physicians caring for children in the ED primarily use nebulizers for bronchodilator delivery and that these physicians have misconceptions regarding the advantages and disadvantages of MDI + S use in children with acute asthma exacerbations.
We obtained a list of members of the emergency medicine (EM) sections of the American Academy of Pediatrics and the Canadian Pediatric Society. A 15-question survey and self-addressed stamped envelope were mailed to each subject (available from the principal investigator on request). Second and third mailings were sent to those not responding within a month of the previous mailing. Surveys returned by self-identified pediatricians not caring for children in an ED setting were excluded. This survey was piloted by a group of 9 pediatric EM physicians and revised prior to the first mailing.
The 15-question survey instrument addressed professional characteristics of the respondent and his or her clinical practice, the presence of asthma management guidelines in their EDs, attitudes toward MDI + S use, self-reported patterns of MDI + S and nebulizer use, and information influencing their choice of bronchodilator delivery method. The survey included multiple choice, Likert scale, and open-ended questions.
Data were entered into a Microsoft Excel 97 spreadsheet (Microsoft Corp, Redmond, Wash) and analyzed using Epi Info 6.015
and SPSS (Statistical Product and Service Solutions; SPSS Inc, Chicago, Ill) software. Bivariate associations between the independent variables and principal outcomes were analyzed using the χ2 test. Multivariate analysis was planned to test the associations between principal outcomes and independent variables. The 2 principal outcomes were self-reported nebulizer use in all patients and MDI + S use in patients with mild acute asthma. Respondent-related independent variables included the average number of clinical hours worked per week (≤16 hours vs >16 hours), number of years of postresidency practice (<5 years, 5-10 years, 10-20 years, and >20 years), position at his or her primary institution (full-time, part-time, or fellow), residency training (EM vs pediatrics), fellowship training (pediatric EM [PEM] vs non-PEM training), country of practice (United States or Canada), setting of practice (general ED or pediatric ED/pediatric area in a general ED), environment in which the respondent's ED was located (urban or suburban/rural), and training programs offered in the respondent's institution (EM residency, pediatrics residency, or PEM fellowship).
This study was approved by the Boston University (Boston, Mass) institutional review board.
Of the 689 subjects contacted, 375 returned surveys. Forty-two respondents not providing emergency care to children were ineligible and excluded from analysis. The overall response rate was 51% (Figure 1).
The majority of physicians had training in pediatrics and PEM (72%). They also generally practiced full-time (83%), commonly in an urban (83%) pediatric ED (80%), and for 5 to 20 postresidency years (83%). Information regarding the characteristics of nonresponders was limited to region of practice. Subjects in the Midwest had the highest nonresponse rate of 65% (51/147 physicians) followed by the West (60%, 29/72), the South (49%, 102/202), and the Northeast (47%, 71/134) (Table 1).
PERCEIVED ADVANTAGES AND DISADVANTAGES TO MDIs
When asked the open-ended question, "What do you think are the advantages to the use of high-dose MDIs (6-8 puffs per treatment) over nebulizers in the emergency department management of pediatric asthma?" the most commonly cited answers addressed cost, speed, and portability. Eighty-five (33%) of 256 respondents stated that MDIs are cheaper. Seventy-two (28%) felt that MDIs are faster to administer. Twenty-two (8%) felt that MDIs require less staff time to use. Sixty-two respondents (24%) stated that the use of MDIs in the ED allows for an opportunity to teach MDI technique to patients and parents. Forty-one (16%) felt that the portability of MDIs is an advantage to their use, and 77 respondents (21%) gave no response.
When subsequently asked: "What do you think are disadvantages to using high-dose MDIs (6-8 puffs per treatment) over nebulizers in the emergency department management of pediatric asthma?" responses most commonly addressed issues of patient dissatisfaction and inconvenience in administration. Sixty-five (24%) of 272 respondents felt that patients and parents expect nebulized therapy when they arrive in an ED and that the use of MDIs would result in patient and parent dissatisfaction. Sixty-two (23%) felt that nebulizers are easier to administer. Similarly, 51 (19%) felt that MDIs would require more staff supervision, 44 (16%) felt MDIs were too difficult to use in the young, and 30 (11%) felt that children are poorly compliant with MDI medication delivery. Some clinical considerations were also voiced. Twelve percent (32/272) felt that nebulizers were superior to MDIs because they can be administered with supplemental oxygen, and 26 (10%) felt that MDIs are less effective than nebulizers when used in children suffering from severe asthma exacerbations. Sixty-one respondents (16%) gave no response.
Self-reported method of bronchodilator use
The majority of physicians deliver bronchodilators by nebulization to all children in the ED. When given a checkbox question asking for which age groups of children (<2 years, 2-5 years, 5-7 years, 7-18 years) they used either nebulizers, MDI + S, or MDI without spacers, 76% of respondents stated that they use nebulizers for all acute patients with acute asthma between 7 and 18 years old. This proportion increased as the age of the patients decreased. Seventy-nine percent, 87%, and 90% of respondents use nebulizers for children in the 5- to 7-year old, 2- to 5-year old, and younger than 2-year-old age groups, respectively. In contrast, a significant minority of respondents stated that they use MDI + S in selected children. The proportion of respondents using MDI + S in children with mild acute asthma decreased with age. Twenty-one percent, 20%, 15%, and 10% stated that they would selectively use MDI + S in children with mild acute asthma aged 7 to 18 years, 5 to 7 years, 2 to 5 years, and younger than 2 years, respectively. The small minority of respondents (3%) who reported selective MDI without spacer use do so only for those with mild acute asthma in the 7- to 18-year-old age group (Table 2).
When asked the open-ended question, "How do you decide which method of bronchodilator delivery you use for any particular child in the emergency department with an asthma exacerbation?" 159 (58%) of 275 respondents stated that they always use nebulized bronchodilators, and 59 (22%) of 275 decide based on the severity of the child's exacerbation. Twenty-five (9%) of 275 reported that they only use the MDI for teaching prior to discharge, 23 (8%) decide based on the age of the patient, and 15 (6%) use their judgment of the patient's ability to cooperate with an MDI to decide (Table 3).
Asthma pathways and mdi+s use
Of the 19 respondents from 16 institutions who provided a copy of their asthma pathway, 3 specified the MDI + S as an option for bronchodilator delivery in the ED.
No differences emerged in bivariate analyses of the independent variables and the principle outcomes of nebulizer use for all patients, and MDI + S use for patients presenting with mild acute asthma. Results of a multivariate analysis are not reported due to small sample size.
The results of this survey suggest that the majority of physicians use nebulizers as their primary method of delivering bronchodilators to children in the ED setting. Despite this, the majority of those surveyed do use MDI + S in some capacity in select children in the ED. Additionally, while some are unaware of the benefits of MDIs, including quicker delivery, lower cost, and increased efficacy in medication delivery, most of the physicians surveyed did not cite inaccurate opinions regarding the efficacy of MDIs in the pediatric acute asthma setting.
The data supporting the use of MDI + S in acute asthma are not new. Meta-analyses reviewing adult and pediatric literature conclude that the 2 methods are equally effective.16,17
These data have been consistent across multiple prospective studies in adults16-21 and children.6-12
Leversha et al22 clearly demonstrated the cost-benefit of using MDI + S in the ED. Williams et al5 also showed that using MDI + S in the pediatric ED was feasible. The 1997 National Heart Lung and Blood Institute and 1993 British Thoracic Society asthma management guidelines both acknowledged the clinical equivalence of MDI + S and nebulizers.23,24 They suggested that MDIs be considered in the ED setting to deliver bronchodilators to children who do not have severe asthma and are able to cooperate. Even this conservative recommendation, however, does not seem to have translated into practice.
Eleven percent of our respondents cited a concern for patient cooperation in MDI medication delivery, and 16% felt the method was too difficult to use in the very young. Clearly, prior to significant improvements in aerosol reservoir technology, MDIs were difficult to use even in cooperative adults and children.25,26 The development of valved spacers has allowed medication delivery to occur efficaciously even when delivered via tidal breathing.5,6,11,12,22,27 Child and infant studies have also documented the equivalence of pulmonary medication delivery using MDI + S and nebulizers to deliver radioactively labeled aerosol vehicles.27-29
Studies have also demonstrated that MDI + S bronchodilator administration requires less staff time.5,12 While it may seem that nebulizers, in practice, require less staff attention, all of the studies comparing these 2 modalities use a facemask with the nebulizer to minimize wasted aerosol. In our opinion, keeping a facemask on an uncooperative young child's face for 10 to 15 minutes requires more effort and supervision than holding a facemask attached to an MDI + S for 3 minutes.
Despite the evidence supporting the use of MDI + S over nebulizers in acute asthma, it does not seem to be the current standard of care in practice. Our attempt to identify populations of pediatric ED physicians who are using MDI + S did not yield any predictive variables by bivariate analysis. Respondent residency or fellowship training, years of practice, and location of practice did not seem to affect how often they used MDI + S in the ED. This, in addition to statements of uniform use of nebulizers, suggests that it is perhaps the culture of the ED and not the individual physician that influences the initial bronchodilator delivery technique used in children. However, it can also be the individual physician who strives to change the culture of the ED.
Changing physician behavior and practicing evidence-based medicine has become an important focus for medicine over the past decade. Evidence-based medicine originates from the ongoing concerns about quality of care, including variation in hospitalization rates, therapeutic interventions, and patient outcomes.30 Despite the overwhelming data suggesting that MDI ± S are equivalent and possibly superior to nebulizers, the results from this survey suggest that they are not being used. As we have previously described, physician decisions are governed by 3 domains: evidence, physician experience, and patient factors.31 The participants in our survey demonstrated a generally good grasp of the evidence supporting the use of MDIs for acute asthma exacerbations. Additionally, the literature suggests a preference for MDIs by patients and parents in the ED. This, in our opinion, suggests that the largest barrier to the routine use of MDIs is the lack of motivation for physicians to change their practice and the culture of their practice environment. Additional environmental barriers to adoption of this technique, including perceived staff reluctance to change, departmental financial barriers, and barriers at the hospital administration level most likely also contribute to the sluggish adoption of new technologies. Changing physician behaviors is quite difficult. The myriad reviews have suggested that education alone is insufficient, and that reminders, opinion leaders, audit and feedback, and administrative interventions can work in specific situations.30-32 While we will need to adopt some of these techniques to encourage the use of MDI + S, motivating physicians to strive for evidence-based practice is ultimately of the utmost importance.
As with any survey, there are limitations of this methodology, including self-reporting bias that may not accurately reflect current practice patterns. However, it is difficult to imagine that the use of MDI + S is greater than reported. Secondly, our response rate was 51%, which may limit generalizability. We have few data on nonresponders, although there is no reason to think that MDI use is greater in nonresponders.
In conclusion, we found that many ED physicians are familiar with the benefits of MDIs. However, a majority do not use them. No differences in MDI + S and nebulizer use patterns were noted based on respondent demographics. External factors may be primarily responsible for the observed underuse of MDI + S in the ED setting among children. Further research is needed to explore ED culture and systems barriers to MDI + S use.
Accepted for publication June 25, 2001.
This study was supported in part by grant #5T32PE1001406 from the Institutional National Research Service Award.
The authors would like to thank Robert Vinci, MD, for his input toward the preparation of the manuscript.
Published literature supports the use of MDI+S for the treatment of acute asthma exacerbations in children; however, our anecdotal experience is that they are rarely used in the ED. To our knowledge to date, there is no published literature regarding current practice by physicians caring for children in an ED setting regarding the type(s) of delivery system(s) used for brochodilator therapy, and attitudes and knowledge toward MDI use for acute asthma exacerbations.
This study defines the current attitudes, knowledge, and use of MDI in the ED for acute asthma exacerbations in children. A majority of physicians caring for pediatric patients with asthma in the emergency department do not use MDIs despite evidence in the literature supporting their use. This study demonstrates the underutilization of evidence-based decisions regarding bronchodilator delivery methods in the ED and will hopefully raise awareness and help to catalyze change of behavior in this area.
Corresponding author and reprints: Irene Tien, MD, Division of Pediatric Emergency Medicine, Boston Medical Center, 1 Boston Medical Center Place, Maternity 6, Boston, MA 02118 (e-mail: irene.tien@bmc.org).
1.Mannino
DMHoma
DMPertowski
CA
et al. Surveillance for asthma: United States 1960-1995.
Morb Mortal Wkly Rep CDC Surveill Summ. 1998;471- 27
Google Scholar 2.Newhouse
MT Asthma therapy with aerosols: are nebulizers obsolete? a continuing controversy.
J Pediatr. 1999;1355- 8
Google ScholarCrossref 3.Kercsmar
CM Aerosol treatment of acute asthma: and the winner is. . . .
J Pediatr. 2000;136428- 431
Google ScholarCrossref 4.O'Callaghan
CBarry
PW How to choose delivery devices for asthma.
Arch Dis Child. 2000;82185- 191
Google ScholarCrossref 5.Williams
JRBothner
JPSwanton
RD Delivery of albuterol in a pediatric emergency department.
Pediatr Emerg Care. 1996;12263- 267
Google ScholarCrossref 6.Kerem
ELevinson
HSchuh
S
et al. Efficacy of albuterol administered by nebulizer vs spacer device in children with acute asthma.
J Pediatr. 1993;123313- 317
Google ScholarCrossref 7.Liu
YZHsieh
KH Metered dose inhaler and nebulizer in acute asthma.
Arch Dis Child. 1995;72214- 218
Google ScholarCrossref 8.Ruggins
NRMilner
ADSwarbrick
A An assessment of a new breath-actuated inhaler device in acutely wheezy children.
Arch Dis Child. 1993;68477- 480
Google ScholarCrossref 9.Schuh
SJohnson
DWStephens
DCallahan
SWinders
PCanny
GJ Comparison of albuterol delivered by MDI with spacer vs a nebulizer in children with mild acute asthma.
J Pediatr. 1999;13522- 27
Google ScholarCrossref 10.Fugelsang
GPedersen
S Comparison of nebuhaler and nebulizer treatment of acute severe asthma in children.
Eur J Respir Dis. 1986;69109- 113
Google Scholar 11.Ba
MSpier
SLapiere
GLamarre
A Wet nebulizer versus spacer and metered dose inhaler via tidal breathing.
J Asthma. 1989;26355- 358
Google ScholarCrossref 12.Chou
KJCunningham
SJCrain
EF Metered-dose inhalers with spacers vs nebulizers for pediatric asthma.
Arch Pediatr Adolesc Med. 1995;149201- 205
Google ScholarCrossref 13.Parkin
PCSaunders
NRDiamond
SAWinders
PMMacArthur
C Randomized trial spacer vs nebuliser for acute asthma.
Arch Dis Child. 1995;72239- 240
Google ScholarCrossref 14.Pendergast
JHopkins
JTimius
BVanAsperer
PP Comparitive efficacy of terbutaline administered by nebuhaler and by nebulizer in young children with acute asthma.
Med J Aust. 1989;151406- 408
Google Scholar 15.Dean
AGDean
JACoulombier
D
et al. Epi Info [computer program]. Version 6. Atlanta, Ga Centers for Disease Control and Prevention1994;
16.Turner
MOPatel
AGinsburg
SFitzgerald
JM Bronchodilator delivery in acute airflow obstruction: a meta-analysis.
Arch Intern Med. 1997;1571736- 1744
Google ScholarCrossref 17.Amirav
INewhouse
MT Metered dose inhaler accessory devices in acute asthma.
Arch Pediatr Adolesc Med. 1997;151876- 882
Google ScholarCrossref 18.Rodrigo
CRodrigo
G Salbutamol treatment of acute severe asthma in the ED: MDI vs hand-held nebulizer.
Am J Emerg Med. 1998;16637- 642
Google ScholarCrossref 19.Colacone
AAfildo
MWolkove
NDreisman
H A comparison of albuterol administered by metered dose inhaler (and holding chamber) or wet nebulizer in acute asthma.
Chest. 1993;104835- 841
Google ScholarCrossref 20.Idris
AHMcDermott
MFRaucci
JCMorrabel
AMcGonray
SHendeles
L Emergency department treatment of severe asthma: metered dose inhaler plus holding chamber is equivalent in effectiveness to nebulizer.
Chest. 1993;103665- 672
Google ScholarCrossref 21.Hodder
RVCalcutt
LELeech
JA Metered dose inhaler with spacer is superior to wet nebulisation for emergency room treatment of acute, severe asthma [abstract].
Chest. 1998;9452
Google Scholar 22.Leversha
AMCampanella
SGAickin
RPAsher
MI Costs and effectiveness of spacer vs nebulizer in young children with moderate and severe acute asthma.
J Pediatr. 2000;136497- 502
Google ScholarCrossref 23.National Heart Lung and Blood Institute, The expert panel report 2: guidelines for the diagnosis and management of asthma. 1997;115111
25.Larsen
JSHahn
MEkholm
BWick
KA Evaluation of conventional press- and breathe metered-dose inhaler technique in 501 patients.
J Asthma. 1994;31193- 199
Google ScholarCrossref 26.Pedersen
SFrost
LArnfred
T Errors in inhalation technique and efficiency in inhaler use in asthmatic children.
Allergy. 1986;41118- 124
Google ScholarCrossref 27.Fok
TFMonkman
SDolovich
M
et al. Efficiency of aerosol medication delivery from a metered dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia.
Pediatr Pulmonol. 1996;21301- 309
Google ScholarCrossref 28.Wildhaber
JHDore
NDDevadason
SGLeSouef
PN Inhalation therapy in asthma: nebulizer or metered-dose inhaler with holding chamber? in vivo comparison of lung deposition in children.
J Pediatr. 1999;13528- 33
Google ScholarCrossref 29.Tal
AGolan
HGrauer
NAviram
MAlbin
DQuastel
MR Deposition pattern of radiolabeled salbutamol inhaled with a mask in young children with airway obstruction.
J Pediatr. 1996;128479- 484
Google ScholarCrossref 30.Bauchner
H Evidence-based medicine: a new science or an epidemiologic fad?
Pediatrics. 1999;1031029- 1031
Google ScholarCrossref 31.Bauchner
HSimpson
LChessare
J Changing physician behavior.
Arch Dis Child. In press
Google Scholar 32.NHS Centre for Reviews and Dissemination, Getting the evidence into practice.
Eff Health Care. 1999;51- 16
Google Scholar