[Skip to Content]
[Skip to Content Landing]
Article
January 1979

Hand-Held Toy Squeaker During Carotid Endarterectomy in the Awake Patient

Author Affiliations

From the Departments of Anesthesiology (Drs Spielberger and Turndorf) and Surgery (Drs Culliford and Imparato), New York University Medical Center, New York.

Arch Surg. 1979;114(1):103-104. doi:10.1001/archsurg.1979.01370250105023
Abstract

• A toy squeaker held by the patient in the contralateral hand is used to monitor cerebral circulation during carotid endarterectomy. Regional anesthesia–cervical plexus block–allowed the patient to cooperate and give useful information, especially during the crucial period of test clamping. In a series of 300 cases, during a period of five years, it was instrumental in avoiding brain damage in 6% of the cases.

(Arch Surg 114:103-104, 1979)

×