Safety of Carbon Dioxide Digital Subtraction Angiography | JAMA Surgery | JAMA Network
[Skip to Navigation]
Access to paid content on this site is currently suspended due to excessive activity being detected from your IP address 18.207.108.182. Please contact the publisher to request reinstatement.
[Skip to Navigation Landing]
Poster Session
Dec 2011

Safety of Carbon Dioxide Digital Subtraction Angiography

Author Affiliations

Author Affiliations: Division of Vascular Surgery and Endovascular Therapy, CardioVascular Thoracic Institute, Keck School of Medicine, University of Southern California, Los Angeles.

Arch Surg. 2011;146(12):1428-1432. doi:10.1001/archsurg.2011.195
Abstract

Objective Reports of fatality following carbon dioxide digital subtraction angiography (CO2-DSA) have raised concerns regarding its safety. This study reviews the safety of CO2-DSA.

Design Single-institution retrospective review.

Setting Tertiary care teaching hospital in Los Angeles, California.

Patients A total of 951 patients who underwent 1007 CO2-DSA procedures during a 21-year period.

Main Outcome Measures Preprocedure and postprocedure creatinine values and periprocedural morbidity and mortality.

Results A total of 632 arterial CO2-DSA were performed; 527 were aortograms with or without extremity runoff; 100, extremity alone; and 5, pulmonary. Venous CO2-DSA included 187 inferior vena cavagrams, 182 hepatic or visceral, 5 extremity venograms, and 1 superior vena cavagram. Associated endovascular procedures were performed in 499 cases; 162 were arterial interventions including 62 endovascular aneurysm repairs, 53 visceral or renal percutaneous angioplasty with/without stent, 41 extremity percutaneous angioplasty with or without a stent, and 4 cases of thrombolysis or embolization; 176 caval filters, 98 transjugular intrahepatic portosystemic shunts, 54 transjugular liver biopsies, and 9 other venous interventions. The mean preprocedure creatinine level was 2.1 mg/dL; postprocedure, 2.1 mg/dL (P = .56). There were a total of 61 (6.1%) procedural complications including 4 (0.4%) mortalities. Two were procedure-related complications: 1, suppurative pancreatitis following aortogram; and 2, hepatic bleed following failed transjugular intrahepatic portosystemic shunts. Two were attributable to patient disease; 1, metastatic adenocarcinoma; and 2, refractory, end-stage cardiomyopathy.

Conclusion Carbon dioxide digital subtraction angiography is a versatile technique that can be safely used for diagnostic and therapeutic endovascular procedures. Morbidity and mortality are acceptable with preservation of renal function. Thus, CO2-DSA is a safe alternative to iodinated contrast.

×