Table 1. 
Patient Characteristicsa
Patient Characteristicsa
Table 2. 
Perioperative Outcomesa
Perioperative Outcomesa
Table 3. 
30-Day Morbidity
30-Day Morbidity
1.
Parodi  JCPalmaz  JCBarone  HD Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.  Ann Vasc Surg 1991;5 (6) 491- 499PubMedGoogle Scholar
2.
Yusuf  SWWhitaker  SCChuter  TAWenham  PWHopkinson  BR Emergency endovascular repair of leaking aortic aneurysm.  Lancet 1994;344 (8937) 1645PubMedGoogle Scholar
3.
Scharrer-Pamler  RKotsis  TKapfer  XGörich  JSunder-Plassmann  L Endovascular stent-graft repair of ruptured aortic aneurysms.  J Endovasc Ther 2003;10 (3) 447- 452PubMedGoogle Scholar
4.
Veith  FJOhki  TLipsitz  ECSuggs  WDCynamon  J Treatment of ruptured abdominal aneurysms with stent grafts: a new gold standard?  Semin Vasc Surg 2003;16 (2) 171- 175PubMedGoogle Scholar
5.
Ohki  TVeith  FJ Endovascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms.  Ann Surg 2000;232 (4) 466- 479PubMedGoogle Scholar
6.
Resch  TMalina  MLindblad  BDias  NCSonesson  BIvancev  K Endovascular repair of ruptured abdominal aortic aneurysms: logistics and short-term results.  J Endovasc Ther 2003;10 (3) 440- 446PubMedGoogle Scholar
7.
Peppelenbosch  NYilmaz  Nvan Marrewijk  C  et al.  Emergency treatment of acute symptomatic or ruptured abdominal aortic aneurysm: outcome of a prospective intent-to-treat by EVAR protocol.  Eur J Vasc Endovasc Surg 2003;26 (3) 303- 310PubMedGoogle Scholar
8.
Van Herzeele  IVermassen  FDurieux  CRandon  CDe Roose  J Endovascular repair of aortic rupture.  Eur J Vasc Endovasc Surg 2003;26 (3) 311- 316PubMedGoogle Scholar
9.
Reichart  MGeelkerken  RHHuisman  ABvan Det  RJde Smit  PVolker  EP Ruptured abdominal aortic aneurysm: endovascular repair if feasible in 40% of patients.  Eur J Vasc Endovasc Surg 2003;26 (5) 479- 486PubMedGoogle Scholar
10.
Lombardi  JVFairman  RMGolden  MA  et al.  The utility of commercially available endografts in the treatment of contained ruptured abdominal aortic aneurysm with hemodynamic stability.  J Vasc Surg 2004;40 (1) 154- 160PubMedGoogle Scholar
11.
Lee  WAHirneise  CMTayyarah  MHuber  TSSeeger  JM Impact of endovascular repair on early outcomes of ruptured abdominal aortic aneurysms.  J Vasc Surg 2004;40 (2) 211- 215PubMedGoogle Scholar
12.
Hechelhammer  LLachat  MLWildermuth  SBettex  DMayer  DPfammatter  T Midterm outcome of endovascular repair of ruptured abdominal aortic aneurysms.  J Vasc Surg 2005;41 (5) 752- 757PubMedGoogle Scholar
13.
Gerassimidis  TSPapazoglou  KOKamparoudis  AG  et al.  Endovascular management of ruptured abdominal aortic aneurysms: 6-year experience from a Greek center.  J Vasc Surg 2005;42 (4) 615- 623PubMedGoogle Scholar
14.
Larzon  TLindgren  RNorgran  L Endovascular treatment of ruptured abdominal aortic aneurysms: a shift of the paradigm?  J Endovasc Ther 2005;12 (5) 548- 555PubMedGoogle Scholar
15.
Dillavou  EDMuluk  SCMakaroun  MS A decade of change in abdominal aortic aneurysm repair in the United States: have we improved outcomes equally between men and women?  J Vasc Surg 2006;43 (2) 230- 238PubMedGoogle Scholar
16.
Djavani  KWanhainen  ABjorck  M Intra-abdominal hypertension and abdominal compartment syndrome following surgery for ruptured abdominal aortic aneurysm [published online ahead of print February 3, 2006].  Eur J Vasc Endovasc Surg 2006;31 (6) 581- 58410.1016/j.ejvs.2005.12.007PubMedGoogle Scholar
17.
Morasch  MDKibbe  MREvans  ME  et al.  Percutaneous repair of abdominal aortic aneurysm.  J Vasc Surg 2004;40 (1) 12- 16PubMedGoogle Scholar
18.
Mehta  MDarling  RC  IIIRoddy  SP  et al.  Factors associated with abdominal compartment syndrome complicating endovascular repair of ruptured abdominal aortic aneurysms.  J Vasc Surg 2005;42 (6) 1047- 1051PubMedGoogle Scholar
19.
Malina  MVeith  FIvancev  KSonesson  B Balloon occlusion of the aorta during endovascular repair of ruptured abdominal aortic aneurysm.  J Endovasc Ther 2005;12 (5) 556- 559PubMedGoogle Scholar
20.
Roberts  KRevell  MYoussef  HBradbury  AWAdam  DJ Hypotensive resuscitation in patients with ruptured abdominal aortic aneurysm [published online ahead of print January 4, 2006].  Eur J Vasc Endovasc Surg 2006;31 (4) 339- 34410.1016/j.ejvs.2005.11.003PubMedGoogle Scholar
Original Article
November 1, 2007

Percutaneous Endovascular Repair of Ruptured Abdominal Aortic Aneurysms

Author Affiliations

Author Affiliations: Division of Vascular Surgery (Drs Najjar, Morasch, Matsumura, and Eskandari) and Department of Surgery (Drs Mueller, Ujiki, and Eskandari), Feinberg School of Medicine, Northwestern University, Chicago, Illinois.

Arch Surg. 2007;142(11):1049-1052. doi:10.1001/archsurg.142.11.1049
Abstract

Hypothesis  Percutaneous endovascular repair of ruptured abdominal aortic aneurysms (RAAAs) has better outcomes than traditional open surgical repair.

Design  Single-center retrospective review.

Setting  University hospital tertiary referral center.

Patients  Thirty-seven RAAAs treated using endovascular repair (n = 15) or open surgery (n = 22).

Interventions  From January 1, 2000, through December 31, 2005, 15 RAAAs were treated with endovascular stent graft exclusion using commercially available systems. Twenty-two other patients undergoing standard open surgical repair during the same interval comprised a control group for comparison.

Main Outcome Measures  Early outcomes of percutaneous endovascular repair of RAAAs.

Results  Among the endovascular group, the mean ± SD age was 73 ± 9.8 years, 86.6% were men (n = 13), and 20.0% had a preoperative systolic blood pressure of 80 mm Hg or lower (n = 3). An entirely percutaneous procedure was performed in the final 11 patients using arterial closure systems. Technical success of attempted endovascular exclusion was 100.0%. The mean ± SD procedure time (107 ± 30 minutes), transfusion requirements (6.6 ± 4.7 U), and length of stay (3.0 ± 6.8 days) were statistically significantly reduced compared with open surgery. The 30-day mortality was 6.7% (1 of 15) compared with an open surgery 30-day mortality of 13.6% (3 of 22). No late complications (pseudoaneurysm, infection, lymphocele, or neuropathy) occurred after a completely percutaneous technique during a mean follow-up of 12 months.

Conclusion  Percutaneous endovascular repair of RAAAs is a more expedient and less morbid alternative than open surgical repair.

Despite improvements in emergent care, the mortality rate of ruptured abdominal aortic aneurysms (RAAAs) remains too high. Since the initial report by Parodi et al1 more than a decade ago, endoluminal exclusion of abdominal aortic aneurysms (AAAs) has revolutionized contemporary treatment options for elective cases. Less frequently cited is a study2 from the Nottingham group demonstrating successful endovascular repair of an RAAA. Subsequent case series3-14 have been published touting the potential advantages of endovascular repair for ruptures as an alternative first-line approach. Perceived benefits focus on the avoidance of a laparotomy, which can be troublesome and may delay quick aortic control in the event of free rupture or a large retroperitoneal hematoma. Recognized risks with open repair include hypothermia, substantial insensible fluid loss, and iatrogenic injury to venous structures, ureter, or bowel.15,16

Since its original description, endovascular repair of AAAs has been conducted mainly through open bilateral femoral artery exposure, allowing for safe introduction of stent graft delivery systems under direct vision. A completely percutaneous modification of this technique using a suture-mediated arterial closure system has been previously reported.17 Advantages of an entirely percutaneous procedure are reduced procedure times, shorter hospital length of stay, earlier ambulation, and fewer wound complications (ie, infection, lymphatic leak, and neuropathy). In cases of RAAAs, an added benefit is the ability to expeditiously access the femoral artery and to place an aortic occlusion balloon to circumvent hemodynamic collapse before the initiation of general anesthesia. This study reviews outcomes after attempting this approach compared with those of a contemporary group of patients treated with traditional open surgical repair.

Methods
Patients

From January 1, 2000, through December 31, 2005, 37 patients with RAAAs were treated at Northwestern Memorial Hospital. Among this group, 22 underwent open repair and 15 were treated using an aortic stent graft. Only patients with documented contained or free rupture were included in the analysis; solely symptomatic patients were excluded in this retrospective review.

Operative procedure

All procedures were performed in a fully functional operating room angiosuite by board-certified vascular surgeons (M.D.M., J.S.M., and M.K.E.) who had extensive endovascular experience. Patients were under general anesthesia. The mean ± SD time elapsed from computed tomographic (CT) scan to the beginning of the operation for all patients was 76.3 ± 40 minutes. Selection of open vs endovascular repair was based on CT images regardless of the presence or absence of active extravasation. Open surgical repair was conducted in standard fashion through a midline laparotomy with selective supraceliac control and selective use of systemic heparin sodium. The proximal anastomosis was in the infrarenal location, and the distal anastomosis was to the aortic bifurcation, iliac artery, or femoral artery.

Anatomical requirements necessary to attempt endovascular repair included the following CT measurements: (1) proximal neck length of 10 mm or longer, (2) proximal neck diameter of 26 mm or narrower, (3) external iliac artery diameter of 7 mm or wider, and (4) lack of excessive calcification or tortuosity of the iliac vessels. Endovascular repair was performed as previously described using the preclose technique.17 Briefly, femoral access was achieved under local anesthesia using an 18-gauge needle and a J-wire, which was secured with an 8F sheath. Access in the common femoral artery was confirmed using fluoroscopic imaging. If needed, an aortic occlusion was used. After the introduction of general anesthesia and achievement of hemodynamic stability, access to the contralateral femoral artery was also secured. Next, a 10F suture-mediated arterial closure device (Prostar; Abbott Vascular Devices, Redwood City, California) was introduced and deployed at each femoral puncture site. The sutures were retrieved, and stent graft delivery sheaths were placed. Sheath sizes ranged from 18F to 12F. Stent graft systems (AneuRx [Medtronic Vascular, Santa Rosa, California] or Excluder [W. L. Gore & Associates, Inc, Tempe, Arizona]) were used. Complete exclusion of the ruptured aneurysm was obtained in a similar fashion to standard elective endovascular repair. At the conclusion of the procedure, the sheaths were removed, and hemostasis of the arteriotomy was obtained using the deployed sutures. Minimal or no systemic heparin treatment was used during these procedures.

Statistical analysis

Measured variables included patient demographics, aneurysm size, preoperative hemoglobin level, operative time, hospital length of stay, and 30-day mortality. Data are expressed as mean ± SD. Unpaired t test (2-tailed) was used for continuous variables and Fisher exact test for categorical variables, with P < .05 considered statistically significant.

Results
Patient characteristics

The clinical patient characteristics are given in Table 1. The mean age ± SD of the total cohort was 73.0 ± 9.6 years, with most patients being male. Roughly one-third of the total cohort had a systolic blood pressure of 80 mm Hg or lower at the initial examination, and all cases were ruptures. Permissive hypotension to maintain a systolic blood pressure of higher than 80 mm Hg was used in all cases. In comparing the 2 groups, age, sex, aneurysm size, systolic blood pressure, and hemoglobin levels were essentially similar on admission.

Perioperative data

As summarized in Table 2, an appreciable difference in procedure times, transfusion requirements, and length of stay were evident when comparing open vs endovascular repair. All of these variables achieved statistical significance at P < .05. The 30-day mortality results also trended in favor of endovascular repair (P =.61).

Among the endovascular group, an aortic occlusion balloon was never required. The first 4 cases were performed via a traditional bilateral femoral artery cutdown approach using the AneuRx endograft system. In 1 case, abdominal compartment syndrome necessitated a decompressive laparotomy, and uncorrectable coagulopathy resulted in this patient's subsequent death. The remaining 11 operations were performed through a completely percutaneous approach using the Excluder endoprosthesis. Two of the last 11 cases were ruptures resulting from delayed failures of a prior elective stent graft (AneuRx). One was a proximal type-1 endoleak due to migration of the graft, and the other was a type-3 endoleak from a fabric tear. The proximal type-1 endoleak was treated using a proximal aortic extension cuff, and the type-3 endoleak was relined. In these 11 cases, percutaneous closure of the arteriotomy failed on 1 side in 1 patient, requiring intraoperative open repair of the femoral artery. Otherwise, there have been no early or late complications (pseudoaneurysm, infection, lymphocele, or neuropathy) attributed to the closure systems. During a mean follow-up of 12 months (range, 3-24 months), 2 type-2 endoleaks have been demonstrated without associated aneurysmal sac enlargement; these were managed with surveillance alone. No instance of proximal or distal type-1 endoleaks, migration, or infection has been identified in follow-up.

Major 30-day events

Thirty-day major morbidity is summarized in Table 3. The aggregate rate after stent grafting was 6.7% (1 of 15) compared with an incidence of 50.0% (11 of 22) following open repair. The occurrence of abdominal compartment syndrome after placement of an AneuRx stent graft system was believed to be due to the confounding factors of diffuse coagulopathy and porosity of the graft material. Similar cases have been reported.18 In subsequent cases, we used a polytef (polytetrafluoroethylene [PTFE])-based stent graft system. Overall mortality was 6.7% (1 of 15) in the endovascular group vs 13.6% (3 of 22) in the open-surgery group. All deaths after open repair were due to primary cardiac events.

Comment

Although many individuals with RAAAs arrive at the hospital alive, those who do require prompt recognition and treatment of their problem to survive. Time, experience, personnel, and blood product availability are the basic institutional components needed to improve the outcomes of traditional open surgical repair. The era of endovascular interventions has added another level of institutional commitment. Although case series9,10 have demonstrated the feasibility of successful emergent endovascular repair of RAAAs, the following 2 key items are mandatory: (1) rapid imaging and (2) on-the-shelf endovascular supplies. This becomes evident when reviewing the outcomes of this study.

Preprocedural CT imaging is essential before embarking on an attempt at elective or emergency repair of aneurysms. Even a noncontrast CT scan can provide the crucial elements necessary to make the decision to proceed with endovascular repair. These elements include an assessment of aortic neck diameter and morphologic structure, as well as access vessel anatomy. Future fluoroscopic imaging units may obviate this need by providing intraoperative CT imaging at the time of the diagnostic angiogram. Nevertheless, intraoperative fluoroscopic imaging with a portable C-arm or preferably a fixed imaging unit in an operating room is an absolute requirement. Desirable adjuncts include a dedicated radiology technician, a well-trained endovascular personnel, and a power injector. Having such a readily available operating room angiosuite allows for expeditious access and control of the aorta.

Control of the aorta and prevention or correction of hemodynamic collapse in cases of rupture can be obtained by brachial or femoral artery access and inflation of an occlusion balloon in the suprarenal aorta.4,19 Some have advocated permissive hypotension as long as the patient is conscious, as well as avoidance of excessive preoperative resuscitation.20 In this study, we favored femoral access as a means for placing an aortic occlusion balloon for the following reasons: (1) It provides the easiest and largest access to the aorta. (2) Access can be achieved under local anesthesia before initiation of general anesthesia. (3) The site may be incorporated as part of the percutaneous stent graft repair. Others have reported on the success of a brachial approach4,5; however, this adds another access site and often requires open surgical repair of the arteriotomy after removal of a delivery sheath capable of accommodating the larger profile of most occlusion balloons. Fortunately, aortic occlusion was not required in any of the cases in this study.

The original descriptions of RAAA endovascular repair were of procedures that were performed outside the United States, where regulatory restrictions are less stringent, or that use custom-made devices.4,5 From a practical viewpoint, the custom-made approach lacks widespread application. The development of commercially available devices has provided all surgeons access to materials usable in an emergent setting. Stocking of aortic stent grafts and other endovascular supplies (ie, occlusion balloons and closure devices) is not only a matter of convenience but also a necessity for institutions that treat emergent cases such as RAAAs. During the past several years, all elective endovascular AAA repairs in our practice have been performed entirely percutaneously using suture-mediated closure systems. As a result, these items are always on hand. Success using this technique prompted us to begin treating all RAAAs in a similar manner. As we have demonstrated, this approach led to a reduction in operative time, transfusion requirements, length of stay, morbidity, and mortality compared with a contemporary group of patients undergoing traditional open repair.

Conclusions

Open surgical repair of RAAAs continues to be associated with exceedingly high morbidity and mortality rates. Endovascular repair of RAAAs is a feasible option. The addition of a readily available operating room angiosuite, a stock supply of stent graft systems, and attempts at a completely percutaneous technique improve early outcomes compared with open repair.

Correspondence: Mark K. Eskandari, MD, Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, 201 E Huron St, Ste 10-105, Chicago, IL 60611 (meskanda@nmh.org).

Accepted for Publication: April 25, 2006.

Author Contributions:Study concept and design: Najjar, Mueller, Morasch, and Eskandari. Acquisition of data: Najjar, Mueller, Morasch, Matsumura, and Eskandari. Analysis and interpretation of data: Najjar, Mueller, Ujiki, and Eskandari. Drafting of the manuscript: Najjar, Mueller, and Eskandari. Critical revision of the manuscript for important intellectual content: Ujiki, Morasch, Matsumura, and Eskandari. Statistical analysis: Mueller and Eskandari. Administrative, technical, and material support: Najjar, Matsumura, and Eskandari. Study supervision: Morasch, Matsumura, and Eskandari.

Financial Disclosure: Dr Morasch received research support from W. L. Gore & Associates, Inc, Guidant Corporation, Cook Incorporated, and Medtronic. He received honoraria for serving as training course director for W. L. Gore & Associates, Inc, Abbott Vascular Devices, and King Pharmaceuticals. Dr Eskandari served as a consultant for Guidant Corporation, Cordis, Abbott Vascular Devices, and W. L. Gore & Associates, Inc.

Previous Presentations: This study was presented at the 11th Annual Winter Meeting of the Peripheral Vascular Surgical Society; January 28, 2006; Park City, Utah.

References
1.
Parodi  JCPalmaz  JCBarone  HD Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.  Ann Vasc Surg 1991;5 (6) 491- 499PubMedGoogle Scholar
2.
Yusuf  SWWhitaker  SCChuter  TAWenham  PWHopkinson  BR Emergency endovascular repair of leaking aortic aneurysm.  Lancet 1994;344 (8937) 1645PubMedGoogle Scholar
3.
Scharrer-Pamler  RKotsis  TKapfer  XGörich  JSunder-Plassmann  L Endovascular stent-graft repair of ruptured aortic aneurysms.  J Endovasc Ther 2003;10 (3) 447- 452PubMedGoogle Scholar
4.
Veith  FJOhki  TLipsitz  ECSuggs  WDCynamon  J Treatment of ruptured abdominal aneurysms with stent grafts: a new gold standard?  Semin Vasc Surg 2003;16 (2) 171- 175PubMedGoogle Scholar
5.
Ohki  TVeith  FJ Endovascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms.  Ann Surg 2000;232 (4) 466- 479PubMedGoogle Scholar
6.
Resch  TMalina  MLindblad  BDias  NCSonesson  BIvancev  K Endovascular repair of ruptured abdominal aortic aneurysms: logistics and short-term results.  J Endovasc Ther 2003;10 (3) 440- 446PubMedGoogle Scholar
7.
Peppelenbosch  NYilmaz  Nvan Marrewijk  C  et al.  Emergency treatment of acute symptomatic or ruptured abdominal aortic aneurysm: outcome of a prospective intent-to-treat by EVAR protocol.  Eur J Vasc Endovasc Surg 2003;26 (3) 303- 310PubMedGoogle Scholar
8.
Van Herzeele  IVermassen  FDurieux  CRandon  CDe Roose  J Endovascular repair of aortic rupture.  Eur J Vasc Endovasc Surg 2003;26 (3) 311- 316PubMedGoogle Scholar
9.
Reichart  MGeelkerken  RHHuisman  ABvan Det  RJde Smit  PVolker  EP Ruptured abdominal aortic aneurysm: endovascular repair if feasible in 40% of patients.  Eur J Vasc Endovasc Surg 2003;26 (5) 479- 486PubMedGoogle Scholar
10.
Lombardi  JVFairman  RMGolden  MA  et al.  The utility of commercially available endografts in the treatment of contained ruptured abdominal aortic aneurysm with hemodynamic stability.  J Vasc Surg 2004;40 (1) 154- 160PubMedGoogle Scholar
11.
Lee  WAHirneise  CMTayyarah  MHuber  TSSeeger  JM Impact of endovascular repair on early outcomes of ruptured abdominal aortic aneurysms.  J Vasc Surg 2004;40 (2) 211- 215PubMedGoogle Scholar
12.
Hechelhammer  LLachat  MLWildermuth  SBettex  DMayer  DPfammatter  T Midterm outcome of endovascular repair of ruptured abdominal aortic aneurysms.  J Vasc Surg 2005;41 (5) 752- 757PubMedGoogle Scholar
13.
Gerassimidis  TSPapazoglou  KOKamparoudis  AG  et al.  Endovascular management of ruptured abdominal aortic aneurysms: 6-year experience from a Greek center.  J Vasc Surg 2005;42 (4) 615- 623PubMedGoogle Scholar
14.
Larzon  TLindgren  RNorgran  L Endovascular treatment of ruptured abdominal aortic aneurysms: a shift of the paradigm?  J Endovasc Ther 2005;12 (5) 548- 555PubMedGoogle Scholar
15.
Dillavou  EDMuluk  SCMakaroun  MS A decade of change in abdominal aortic aneurysm repair in the United States: have we improved outcomes equally between men and women?  J Vasc Surg 2006;43 (2) 230- 238PubMedGoogle Scholar
16.
Djavani  KWanhainen  ABjorck  M Intra-abdominal hypertension and abdominal compartment syndrome following surgery for ruptured abdominal aortic aneurysm [published online ahead of print February 3, 2006].  Eur J Vasc Endovasc Surg 2006;31 (6) 581- 58410.1016/j.ejvs.2005.12.007PubMedGoogle Scholar
17.
Morasch  MDKibbe  MREvans  ME  et al.  Percutaneous repair of abdominal aortic aneurysm.  J Vasc Surg 2004;40 (1) 12- 16PubMedGoogle Scholar
18.
Mehta  MDarling  RC  IIIRoddy  SP  et al.  Factors associated with abdominal compartment syndrome complicating endovascular repair of ruptured abdominal aortic aneurysms.  J Vasc Surg 2005;42 (6) 1047- 1051PubMedGoogle Scholar
19.
Malina  MVeith  FIvancev  KSonesson  B Balloon occlusion of the aorta during endovascular repair of ruptured abdominal aortic aneurysm.  J Endovasc Ther 2005;12 (5) 556- 559PubMedGoogle Scholar
20.
Roberts  KRevell  MYoussef  HBradbury  AWAdam  DJ Hypotensive resuscitation in patients with ruptured abdominal aortic aneurysm [published online ahead of print January 4, 2006].  Eur J Vasc Endovasc Surg 2006;31 (4) 339- 34410.1016/j.ejvs.2005.11.003PubMedGoogle Scholar
×