Objective
To examine the impact of adherence to a ventilator-associated pneumonia (VAP) bundle on the incidence of VAP in our surgical intensive care units (SICUs).
Design
Prospectively collected data were retrospectively examined from our Infection Control Committee surveillance database of SICU patients over a 38-month period. Cost of VAP was estimated at $30 000 per patient stay.
Setting
Two SICUs at a tertiary care academic level I trauma center.
Patients
Ventilated patients admitted to a SICU.
Intervention
The Institute for Healthcare Improvement VAP bundle was instituted at the beginning of the study and included head-of-bed elevation, extubation assessment, sedation break, peptic ulcer prophylaxis, and deep vein thrombosis prophylaxis. A daily checklist was considered compliant if all 5 items were performed for each patient.
Main Outcome Measures
Patients were assessed for VAP. Staff were assessed for compliance with the VAP bundle.
Results
Prior to initiation of the bundle, VAP was seen at a rate of 10.2 cases/1000 ventilator days. Compliance with the VAP bundle increased over the study period from 53% and 63% to 91% and 81% in each respective SICU. The rate of VAP decreased to 3.4 cases/1000 ventilator days. A cost savings of $1.08 million was estimated.
Conclusions
Initiation of the VAP bundle is associated with a significantly reduced incidence of VAP in patients in the SICU and with cost savings. Initiation of a VAP bundle protocol is an effective method for VAP reduction when compliance is maintained.
Prevention of ventilator-associated-pneumonia (VAP) has become a priority for all intensive care units (ICUs) in the United States.1,2 The critical importance of this issue reflects the high incidence (5.2 VAP cases/1000 ventilator days in surgical ICUs [SICUs] and 10.2 VAP cases/1000 ventilator days in trauma ICUs,3 making VAP among the most common infection in ICUs4) and the high cost of treatment ($11 000-$57 000).5-7 Although increased attributable mortality in this group is controversial,5,6,8-12 it is clear that those with VAP spend additional days on the ventilator,6 additional days in the ICU,5-9,11 and additional days in the hospital.5-8 Adding to the pressure to eliminate VAP, the Centers for Medicare and Medicaid Services have announced that they may cease to reimburse hospitals for costs incurred as a result of VAP,13 thus shifting this profound financial burden directly to hospitals.
Evidence-based clinical practice guidelines aimed at reducing VAP have been available for many years14,15 and include dozens of clear prevention strategies. Sadly, widely published guidelines often do not result in changed behaviors in the clinical setting,16 and VAP prevention guidelines have proven no exception.17
Awareness of the gap between guideline dissemination and clinical practice has led to efforts by individual hospitals and health care systems to institute programs aimed at complying with VAP prevention guidelines to reduce the burden of this nosocomial infection. The bundle approach has been very successful at effecting evidence-based recommendations.18-26
When our institution's SICUs revealed mediocre VAP rates in 2006, a bundle practice was adopted to reduce this complication. By complying with 4 VAP bundle elements described by the Institute for Healthcare Improvement (IHI),17 we believed that we could lessen our VAP burden.
Boston Medical Center is a 626-bed urban academic tertiary care center with a level I trauma designation. Our 2 SICUs include a closed 12-bed trauma/general surgery ICU (TICU) and an open 16-bed surgical ICU where patients are admitted from general and subspecialty surgery services (SICU). Combined, our ICUs admit approximately 1600 critically ill patients annually.
Daily assessment of bundle goals and order entry were performed by a multidisciplinary team including physicians, nurse practitioners, bedside SICU nurses, and pharmacists. Bedside SICU nurses were responsible for head-of-bed (HOB) elevation and for providing daily sedation breaks based on the Riker score.
Our VAP bundle initiative was assessed through retrospective review of prospectively collected data from infection control and trauma databases. The study period began March 1, 2006, when data on VAP incidence were collected prior to bundle initiation and includes data collected through May 31, 2009.
The VAP bundle program began October 1, 2006. Compliance data were collected from then until May 31, 2009, a 31-month period. Data were grouped by fiscal and calendar years.
This study was performed using public databases and did not require institutional review board approval.
The VAP bundle adopted at our institution differed from the IHI bundle in that we teased apart “daily sedation vacations and assessment of readiness to extubate” into 2 individual components. Our bundle components were as follows: (1) HOB elevation greater than 30°, (2) daily sedation break, (3) daily assessment for extubation, (4) peptic ulcer prophylaxis, and (5) deep vein thrombosis prophylaxis.
Compliance was assessed twice daily by the respiratory care service, who entered data into an electronic database. Compliance was recorded as yes or no for each bundle item. The entire bundle was considered compliant only if all 5 items were compliant. A bundle was considered noncompliant if any item was not performed, even if that item was contraindicated. The only exception was contraindication to deep vein thrombosis prophylaxis in patients with head injury; the bundle was still considered compliant in this case.
Compliance data were summarized on a weekly basis. These data were reviewed monthly by a multidisciplinary team including intensive care nursing managers who supplied feedback to the SICU nursing staff.
The primary outcome measure was the relationship between VAP bundle compliance and VAP incidence. Cases of VAP were identified by the infection control team during routine daily surveillance rounds through the ICUs using Centers for Disease Control and Prevention criteria.27 All suspected VAP cases were reviewed thoroughly, including individual radiographs by the infection control team of nurses and physicians before a VAP diagnosis was confirmed. The members of the infection control team did not change during the study period.
Rates of VAP were defined as the number of VAP cases per 1000 ventilator days. Ventilator days were counted daily by the infection control team. A ventilator day was defined as a calendar day for which the patient was charged for mechanical ventilation.
A secondary outcome of interest was the cost savings resulting from the VAP bundle program. At our institution, the cost to treat a VAP case was estimated to be $30 000 based on average costs documented in the literature.5-7
Differences in VAP rates were compared using the χ2 test. Summary statistics are provided as annual VAP rate (VAP cases per 1000 ventilator days) with P value. Annual percentage of compliance was compared via 95% confidence intervals.
Total bundle compliance increased every year in both SICUs throughout the study (Figure 1), from 53% to 91% in the TICU and from 63% to 81% in the SICU. The TICU showed the greatest increase in total compliance. Both ICUs showed greater improvement in overall compliance between the first and second years of the study than between the second and third years of the study.
Individual bundle items also showed improvement during the study period (Table). The HOB elevation and deep vein thrombosis prophylaxis bundle elements were initially the most deficient, but they improved greatly by the end of the study. Compliance with peptic ulcer prophylaxis, sedation break, and assessment for extubation were initially excellent and remained at or higher than 92% throughout the study.
The overall VAP rates in our 2 ICUs were similar prior to the bundle program (Figure 2) and were comparable to the 50th percentile reported by the 2004 National Nosocomial Infections Surveillance System28 for SICUs and TICUs.
The incidence of VAP decreased in each ICU during the study period. The TICU had a greater and more statistically significant reduction in VAP compared with the SICU, which only approached statistical significance. The VAP incidence at the SICU increased slightly during the first year of the VAP bundle program but showed the greatest decrease during the second year. The TICU saw the greatest decrease in VAP during the third study year.
Combined VAP rates decreased during the study period and were statistically significant in 2008 and 2009 (Figure 2). This suggests a 67% risk reduction by the end of the study period.
The combined VAP incidence in our ICUs was 10.2 VAP cases/1000 ventilator days at the beginning of the study period. At that rate, 36 additional VAP cases would have been acquired by our patients during the study without the bundle. At an estimated expense of $30 000 (±$20 000)/VAP case, $1 080 000 ($360 000-$1 800 000) was saved as a result of VAP prevention.
Our data show a correlation between VAP bundle compliance and reduction in VAP incidence. This effect was seen across 2 separate SICUs at our institution, it was sustained for 3 years, and it saw our VAP incidence decrease between the 10th and 25th national percentiles for SICUs and TICUs by the end of the study period. Prior to initiation of the VAP bundle, the VAP incidence was slightly higher at the TICU than at the SICU. We attribute this to the trauma population treated at the TICU and their higher risk of VAP. Overall compliance was proportional to the decrease in the VAP rate. The TICU experienced a higher level of compliance and a lower VAP rate at the end of 3 years than the SICU. This was likely because the VAP bundle project was initiated by TICU staff, although this does not explain why the first year saw better compliance at the SICU.
Of the individual bundle elements, compliance with HOB elevation had the greatest impact on VAP reduction. Compliance with HOB elevation was initially very low in both ICUs but had the greatest improvement during the study period. Deep vein thrombolysis prophylaxis compliance, also initially poor, improved but does not contribute to VAP reduction. Other bundle elements had excellent compliance throughout the study period. Head-of-bed elevation was the single element associated with reducing VAP risk that improved during the study period.
Evidence-based guidelines for the prevention of nosocomial pneumonia have been published and revised by the Centers for Disease Control and Prevention since the 1980s.13,14,29,30 Since the publication of these guidelines, a decrease in the VAP rate has been appreciated by the National Nosocomial Infections Surveillance System. The SICU VAP rate was 25 VAP cases/1000 ventilator days in 1987 and decreased to 15 by 1991,31 to 9.3 by 2004,28 and to 5.2 in 2006.3
Manangan et al31 described compliance data obtained in 1995 via mailed self-report surveys regarding recommendations for management of ventilator equipment. This group found that compliance with timing of breathing circuit change (category 1A recommendation) had increased from 65% to 98% and that compliance with routine changing of the hygroscopic condenser-humidifiers or heat-moisture exchangers (category 1B recommendation) increased from 62% to 93% since guideline publication. Most other recommended practices were not as well heeded or showed little change in behavior.
In 1999, Cabana et al16 reviewed 76 studies that examined guideline compliance and concluded that although the guidelines are widely distributed, they have only a small impact on changing physician practice. Rello et al17 confirmed this disappointing reality for VAP guidelines as well. In this international study, critical care physicians deemed “opinion leaders” in the field of VAP were surveyed about evidence-based guidelines described by Kollef.14 Rello and colleagues discovered a 25.2% noncompliance rate for recommended guidelines; noncompliance rates of 41.3% and 35.7% were seen for grade A and B recommendations, respectively. While Rello and colleagues found “disagreement with interpretation of reported trials”17 and “lack of resources”17 to be the main factors for noncompliance, Cabana and colleagues reported “lack of awareness, lack of familiarity, lack of self-efficacy, lack of outcome expectance, and inertia of previous practice”16 as important barriers to implementing guidelines.
Acknowledgment of widespread guideline noncompliance led to speculation by Sinuff et al32 into methods for improving knowledge translation relevant to VAP prevention in ICUs. This group suggested that a multifaceted approach would yield the greatest success. An active educational strategy combined with reminders, audit, and feedback led by a guidance implementation team was recommended for further study. Craven4 similarly advised that a cure for poor compliance with VAP guidelines should involve a multidisciplinary team that sets prevention benchmarks, establishes goals and timelines, and provides education, training, audits, and feedback.
An enormous amount of effort has been spent overcoming barriers to guideline implementation. The earliest programs aimed at reducing VAP by complying with established recommendations were described in the mid-1990s.
Kelleghan et al33 described a 1989 quality improvement project at Kaiser Permanente in California that was modeled after the principles of continuous quality improvement described by W. Edwards Deming, PhD. This is among the earliest attempts at reducing VAP incidence by enforcing existent infection control and prevention guidelines. With a multipronged approach, a multidisciplinary infection prevention team established a checklist of respiratory guidelines for staff, addressed barriers to compliance, instituted a hand-washing surveillance program, held educational seminars, began prospective VAP surveillance, and gave compliance feedback. This institution had a 57% reduction in VAP in 1 year, estimating 15 VAP cases prevented, 3 lives saved, and $105 000 in cost savings.
Joiner et al34 described similar efforts in Ohio in 1992. Also borrowing from continuous quality improvement theory, which stipulates that outcome improvement stems from change in process, a multidisciplinary quality improvement team compared the institution's process of ventilator care management with evidence-based best-care practices and created a protocol to eliminate the gap between current and best care. The VAP and process evaluation data were collected and reviewed monthly, and areas for improvement were addressed. This institution also saw a dramatic decrease in VAP incidence, from 26 to 16 VAP cases/1000 ventilator days, saving approximately $126 000 over 3 years.
The VAP bundle concept grew from the IHI's 100 000 Lives Campaign to reduce VAP incidence.1 The bundle is a “small set of evidence-based interventions for patients on mechanical ventilation.”18 Created in 2002, the IHI-defined bundle included 4 elements: HOB elevation, daily sedation vacation, peptic ulcer prophylaxis, and deep vein thrombosis prophylaxis. Clinical evidence supports that each item reduces patient mortality and morbidity18 and that patients on mechanical ventilation should receive these things, despite the fact that only HOB elevation and sedation vacation reduce VAP risk.
In 2005, Resar et al19 described the IHI Impact Network's experience implementing the IHI VAP bundle at 61 hospitals. The ICUs achieving greater than 95% compliance saw a 59% reduction in VAP rates. Resar and colleagues emphasized that while bundle use may improve clinical outcomes, its use would also improve process reliability. They speculated further that the multidisciplinary teams, daily goal-setting, and increased attention to detail stimulated by the bundle importantly contributed to improved clinical outcomes.
Cocanour et al21 described VAP bundle use in their Houston, Texas, TICU. On discovery of high VAP incidence, a bundle program that included elements of the IHI VAP bundle in addition to several other precautions was initiated. The initial improvements in VAP incidence were modest and unsustained. When a computerized audit tool was implemented to calculate weekly bundle compliance data, the VAP rate decreased below the National Nosocomial Infections Surveillance System's 25th percentile and was sustained for the remaining months of the study. This result reveals the importance of process quality evaluation and feedback in improving clinical outcome when using a bundle.
A similar experience was described by Hawe et al20 in Scotland. They implemented a similar VAP bundle by displaying copies of the protocol at every ICU bedside. Compliance, assessed only periodically, was dismal during this passive implementation phase and no VAP reduction was seen. An active implementation phase that included educational workshops, compliance reporting, addressing barriers to delivery, and discussion of bundle adherence on daily multidisciplinary rounds was initiated. Compliance improved from 0% to 54% and VAP rates decreased dramatically from 19.17 to 7.5 VAP cases/1000 ventilator days. Here, the education, feedback, and daily goal-setting were key to clinical success.
Zaydfudim et al25 made compliance feedback the keystone of their VAP bundle program in Nashville, Tennessee. When implementation of a bundle program with intermittent compliance monitoring failed to reduce VAP incidence, a real-time VAP bundle compliance dashboard was installed on every SICU computer monitor. Daily compliance reports were reviewed by multidisciplinary rounding teams and by physician and nursing leaders. Real-time compliance feedback resulted in an increase in total bundle compliance from approximately 20% to about 90% over 1 year. Compliance with individual bundle items increased in every parameter during the study period, and overall VAP rates improved.
We attribute the success of our VAP bundle program to several of the factors described earlier. First, we used a concise, well-established bundle described by the IHI17,25 where each component has a well-documented impact on morbidity.18 Numerous other ICUs in the United States have had success in decreasing VAP incidence using the IHI bundle.17 Second, our comprehensive approach to bundle implementation and its incorporation to daily rounds and goal-setting contributed to our success.18 Daily multidisciplinary rounds with a checklist by a team including nurses, pharmacists, and physicians ensured that bundle-appropriate orders were entered and completed. Our system of regular audit and feedback may have made the greatest impact on bundle compliance. The VAP compliance and incidence data were reviewed weekly, monthly, and quarterly. Weekly data were summarized in an electronic newsletter that included days since last VAP. Quarterly VAP data were posted in several locations throughout the hospitals and the ICUs. Nursing supervisors who attended monthly meetings discussed compliance data, comparing current and prior performance, and provided feedback to the ICU nursing staff. Presumably once the trend in reduced VAP incidence became apparent with improved bundle compliance, the staff became even more motivated to improve performance. These same feedback and reminder mechanisms continue presently.
Strengths of our study include the large number of patients (approximately 4000) treated in our SICUs over 2½ years. The similar results achieved at both SICUs underscore the validity of our results. Another important strength is the measurement of our primary outcome (VAP incidence) by an experienced, unchanging infection control team.
Among the weaknesses of this study, we did not compare our SICU populations between units or years. It is possible that healthier patients with fewer risk factors for VAP were admitted in 2009 than in 2006. We did not account for contraindications to VAP bundle items when scoring compliance. This may have led to underestimation of actual guideline compliance. Finally, the greatest weakness of our study is that it does not account for other ongoing programs at out institution aimed at reducing nosocomial infections, including a hand-washing campaign, blood glucose control protocols, a chlorhexidine gluconate mouthwash protocol, and availability of an endotracheal tube that supports continuous aspiration of subglottic secretions. While we have documented improved compliance with hand washing, which may have had an impact on our VAP rates, compliance data are not available for the other interventions. Use of chlorhexidine mouthwash and of the endotracheal tube that supports continuous aspiration of subglottic secretions began in 2005 at our institution, 1 year prior to initiation of the bundle program.
In summary, our study demonstrates the success of a VAP bundle in reducing the incidence of VAP and in cutting costs in 2 SICUs when excellent compliance is maintained. Compliance was achieved by incorporating the bundle into daily multidisciplinary rounds and through regular audit and feedback. This is a simple, inexpensive, effective method of reducing VAP in the SICU.
Correspondence: Dorothy Bird, MD, Department of Surgery, Boston Medical Center, 88 E Newton St, Boston, MA 02118 (dorothy.bird@bmc.org).
Accepted for Publication: November 12, 2009.
Author Contributions:Study concept and design: Zambuto, O’Donnell, and Agarwal. Acquisition of data: O’Donnell, Silva, Korn, and R. Burke. Analysis and interpretation of data: Bird, O’Donnell, R. Burke, P. Burke, and Agarwal. Drafting of the manuscript: Bird. Critical revision of the manuscript for important intellectual content: Bird, Zambuto, O’Donnell, Silva, Korn, R. Burke, P. Burke, and Agarwal. Statistical analysis: Bird. Administrative, technical, and material support: Zambuto, O’Donnell, Silva, Korn, R. Burke, and Agarwal. Study supervision: P. Burke and Agarwal.
Financial Disclosure: None reported.
Previous Presentation: This paper was presented at the 90th Annual Meeting of the New England Surgical Society; September 11, 2009; Newport, Rhode Island; and is published after peer review and revision.
1.Berwick
DMCalkins
DR McCannon
CJHackbarth
AD The 100 000 Lives Campaign: setting a goal and a deadline for improving health care quality.
JAMA 2006;295
(3)
324- 327
PubMedGoogle ScholarCrossref 3.Edwards
JRPeterson
KDAndrus
ML
et al. NHSN Facilities, National Healthcare Safety Network (NHSN) report, data summary for 2006, issued June 2007.
Am J Infect Control 2007;35
(5)
290- 301
PubMedGoogle ScholarCrossref 5.Warren
DKShukla
SJOlsen
MA
et al. Outcome and attributable cost of ventilator-associated pneumonia among intensive care unit patients in a suburban medical center.
Crit Care Med 2003;31
(5)
1312- 1317
PubMedGoogle ScholarCrossref 6.Rello
JOllendorf
DAOster
G
et al. VAP Outcomes Scientific Advisory Group, Epidemiology and outcomes of ventilator-associated pneumonia in a large US database.
Chest 2002;122
(6)
2115- 2121
PubMedGoogle ScholarCrossref 7.Cocanour
CSOstrosky-Zeichner
LPeninger
M
et al. Cost of a ventilator-associated pneumonia in a shock-trauma intensive care unit.
Surg Infect (Larchmt) 2005;6
(1)
65- 72
PubMedGoogle ScholarCrossref 8.Fagon
JYChastre
JHance
AJMontravers
PNovara
AGibert
C Nosocomial pneumonia in ventilated patients: a cohort study evaluating attributable mortality and hospital stay.
Am J Med 1993;94
(3)
281- 288
PubMedGoogle ScholarCrossref 9.Ibrahim
EHTracy
LHill
CFraser
VJKollef
MH The occurrence of ventilator-associated pneumonia in a community hospital: risk factors and clinical outcomes.
Chest 2001;120
(2)
555- 561
PubMedGoogle ScholarCrossref 10.Heyland
DKCook
DJGriffith
LKeenan
SPBrun-Buisson
CCanadian Critical Trials Group, The attributable morbidity and mortality of ventilator-associated pneumonia in the critically ill patient.
Am J Respir Crit Care Med 1999;159
(4, pt 1)
1249- 1256
PubMedGoogle ScholarCrossref 11.Rello
JQuintana
EAusina
V
et al. Incidence, etiology, and outcome of nosocomial pneumonia in mechanically ventilated patients.
Chest 1991;100
(2)
439- 444
PubMedGoogle ScholarCrossref 12.Cook
D Ventilator associated pneumonia: perspectives on the burden of illness.
Intensive Care Med 2000;26
((suppl 1))
S31- S37
PubMedGoogle ScholarCrossref 13.Centers for Medicare and Medicaid Services CMS proposes to expand quality program for hospital inpatient services in FY 2009 [press release, April 14, 2008].
See website
here. Accessed August 13, 2009
15.Muscedere
JDodek
PKeenan
SFowler
RCook
DHeyland
DVAP Guidelines Committee and the Canadian Critical Care Trials Group, Comprehensive evidence-based clinical practice guidelines for ventilator-associated pneumonia: prevention.
J Crit Care 2008;23
(1)
126- 137
PubMedGoogle ScholarCrossref 16.Cabana
MDRand
CSPowe
NR
et al. Why don't physicians follow clinical practice guidelines? a framework for improvement.
JAMA 1999;282
(15)
1458- 1465
PubMedGoogle ScholarCrossref 17.Rello
JLorente
CBodi
MDiaz
ERicart
MKollef
MH Why do physicians not follow evidence-based guidelines for preventing ventilator-associated pneumonia? a survey based on the opinions of an international panel of intensivists.
Chest 2002;122
(2)
656- 661
PubMedGoogle ScholarCrossref 19.Resar
RPronovost
PHaraden
CSimmonds
TRainey
TNolan
T Using a bundle approach to improve ventilator care processes and reduce ventilator-associated pneumonia.
Jt Comm J Qual Patient Saf 2005;31
(5)
243- 248
PubMedGoogle Scholar 20.Hawe
CSEllis
KSCairns
CJLongmate
A Reduction of ventilator-associated pneumonia: active vs passive guideline implementation.
Intensive Care Med 2009;35
(7)
1180- 1186
PubMedGoogle ScholarCrossref 21.Cocanour
CSPeninger
MDomonoske
BD
et al. Decreasing ventilator-associated pneumonia in a trauma ICU.
J Trauma 2006;61
(1)
122- 130
PubMedGoogle ScholarCrossref 22.Tolentino-DelosReyes
AFRuppert
SDShiao
SY Evidence-based practice: use of the ventilator bundle to prevent ventilator-associated pneumonia.
Am J Crit Care 2007;16
(1)
20- 27
PubMedGoogle Scholar 23.Lansford
TMoncure
MCarlton
E
et al. Efficacy of a pneumonia prevention protocol in the reduction of ventilator-associated pneumonia in trauma patients.
Surg Infect (Larchmt) 2007;8
(5)
505- 510
PubMedGoogle ScholarCrossref 24.Papadimos
TJHensley
SJDuggan
JM
et al. Implementation of the “FASTHUG” concept decreases the incidence of ventilator-associated pneumonia in a surgical intensive care unit.
Patient Saf Surg 2008;23
PubMedGoogle ScholarCrossref 25.Zaydfudim
VDossett
LAStarmer
JM
et al. Implementation of a real-time compliance dashboard to help reduce SICU ventilator-associated pneumonia with the ventilator bundle.
Arch Surg 2009;144
(7)
656- 662
PubMedGoogle ScholarCrossref 26.Joint Commission on Accreditation of Healthcare Organizations, Raising the bar with bundles: treating patients with an all-or-nothing standard.
Jt Comm Perspectives on Patient Saf 2006;6
(4)
5- 6
Google Scholar 27.Horan
TCAndrus
MDudeck
MA CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting.
Am J Infect Control 2008;36
(5)
309- 332
PubMedGoogle ScholarCrossref 28.National Nosocomial Infections Surveillance System, National Nosocomial Infections Surveillance (NNIS) System report, data summary from January 1992 through June 2004, issued October 2004.
Am J Infect Control 2004;32
(8)
470- 485
PubMedGoogle ScholarCrossref 30.Tablan
OCAnderson
LJArden
NHBreiman
RFButler
JC McNeil
MMHospital Infection Control Practices Advisory Committee, Centers for Disease Control and Prevention, Guideline for prevention of nosocomial pneumonia.
Am J Infect Control 1994;22
(4)
247- 292
PubMedGoogle ScholarCrossref 31.Manangan
LPBanerjee
SNJarvis
WR Association between implementation of CDC recommendations and ventilator-associated pneumonia at selected US hospitals.
Am J Infect Control 2000;28
(3)
222- 227
PubMedGoogle ScholarCrossref 32.Sinuff
TMuscedere
JCook
DDodek
PHeyland
DCanadian Critical Care Trials Group, Ventilator-associated pneumonia: improving outcomes through guideline implementation.
J Crit Care 2008;23
(1)
118- 125
PubMedGoogle ScholarCrossref 33.Kelleghan
SISalemi
CPadilla
S
et al. An effective continuous quality improvement approach to the prevention of ventilator-associated pneumonia.
Am J Infect Control 1993;21
(6)
322- 330
PubMedGoogle ScholarCrossref 34.Joiner
GASalisbury
DBollin
GE Utilizing quality assurance as a tool for reducing the risk of nosocomial ventilator-associated pneumonia.
Am J Med Qual 1996;11
(2)
100- 103
PubMedGoogle ScholarCrossref